Walk up the loft ladder in most houses built around Basingstoke since the 1960s and you will see the same thing: a row of identical timber triangles, evenly spaced, joined at every corner with toothed metal plates. That is a trussed rafter roof, and it is the single most important fact about where a roof window can go. This guide explains what those trusses are doing, how to tell whether your roof has them, and how a rooflight is chosen so that it drops neatly between them instead of cutting through them.
The short version is simple. In a trussed roof the window is sized to the roof, not the roof to the window. Get that order right and a dark landing, a loft room or a back bedroom gets daylight without anyone touching the structure that holds the roof up.
What a trussed rafter roof actually is
A trussed rafter is a complete triangle of timber made in a factory, not a set of loose rafters cut and nailed on site. Each one has a pair of rafters (the top chords), a ceiling tie along the bottom (the bottom chord), and a set of internal members called webs that brace the triangle from the inside. The joints are held with punched metal nail plates pressed into the timber by machine. On most estate houses the webs form a W shape, which is why the common pattern is called a Fink or W truss.
The trusses arrive on a lorry, are lifted onto the wall plates and are fixed at regular centres, typically 600mm apart. Once they are up, they are tied together with bracing: long timbers running along the roof, and diagonal braces running from the eaves towards the ridge. That bracing stops the whole row from leaning over like a line of dominoes and helps the roof resist wind.
The point that matters for a roof window is this: no single member in a truss is spare. The webs, the chords and the plates were designed together, by the truss manufacturer, as one engineered component, and the row of trusses with its bracing was designed as one roof. Each truss is slimmer than a traditional rafter precisely because it relies on every other part of the triangle doing its job.
Sizing a roof window to the truss bays
- Fink trussed rafter, factory made and designed to work as one whole frame
- W-shaped webs, joined at every node by pressed metal nail plates
- Tile covering on battens over the underlay
- Roof window set in the slope, fitted between trusses so the frame is untouched
- Narrow roof window sitting in the bay between two trusses
- Trusses at even 600mm centres along the roof
- No truss cut: the trusses either side of the window stay whole
- A wider window crosses a truss, so the cut needs designed trimming from an engineer or the truss maker
How to tell whether your roof is trussed or cut
Before anyone talks about window sizes, it helps to know which kind of roof you are standing under. You can usually tell in a few minutes with a torch from the loft hatch. The clues below are the ones a surveyor looks for first.
| What to look at | Trussed rafter roof | Cut rafter roof |
|---|---|---|
| Joints | Flat toothed metal plates on both faces of every joint | Nailed or bolted timber joints, often notched where rafters sit on the wall plate |
| Internal timbers | Diagonal webs, usually in a W, repeated in every truss | Purlins running along the slope, propped by struts down to a load-bearing wall |
| Spacing | Regular, typically 600mm centres all the way along | Varies by builder and era; closer spacing is common |
| Loft space | Crowded with webs; hard to stand or store between them | More open floor between purlins and struts |
| Ridge | Trusses meet at a jointed apex, often with no ridge board | Rafters pitched against a continuous ridge board |
| Typical houses | Estate homes from the 1960s onward, including most new builds | Victorian, Edwardian and interwar houses, older village cottages |
Most of the post-war estates around the town, from Popley and Oakridge to Brighton Hill, Chineham and Hatch Warren, are trussed. The older village cores such as Old Basing and Overton are more likely to be cut. If your loft shows purlins, struts and a ridge board, the thinking changes, and our guide to roof windows in older cut rafter roofs covers that roof instead. Some houses have both: an original cut roof with a later trussed extension, so it is worth checking each slope you are thinking about.
Why a truss is never cut on instinct
The quickest way to fit a big roof window is to cut out whatever timber is in the way. On a cut rafter roof that can sometimes be done properly, with the cut rafter carried on trimmers. On a trussed roof, doing it by eye is a different matter altogether. Cutting a chord or a web changes how the loads travel through that truss, and through the trusses beside it, in ways the original design never allowed for.
The damage is rarely dramatic on the day. The tiles go back on, the ceiling is made good and the room looks finished. Problems show later, as a slope that begins to dip, a ceiling that cracks along a line, or tiles that no longer sit true. By then the cause is hidden behind plasterboard.
The rule: in a trussed rafter roof the window goes between the trusses, and no chord, web or plate is cut. The exception is a wider opening that has been designed for, on paper, by an engineer or the truss manufacturer, with the trimming specified before anyone picks up a saw.
If you want the direct answer to that question on its own, see can you cut a roof truss to fit a roof window? It gives the yes, no and only-if in a few paragraphs.
Choosing a window width that drops between the trusses
With trusses at 600mm centres, the clear gap between two of them is a little less than 600mm, because the width of the timber itself comes out of the measurement. The roof window manufacturers know this well. Their ranges include narrow widths made to sit between standard truss spacings, with room left for the frame to be fixed and insulated properly on each side.
Fitting one of those windows does not touch the truss at all. The installer forms the opening by fixing short timbers across the gap, above and below where the window will sit, between the two trusses. The tile battens and the covering are cut back to the new opening, the window frame is fixed to the new timbers and the trusses, and the flashing is fitted around it. Every truss stays whole.

The height of the window is more flexible than the width. Roof windows come in several heights, so a between-the-trusses window can still be tall enough to give a good view and plenty of daylight, especially on a steeper slope. The full list of which common widths fit, which are tight, and which always need trimming is in our guide to roof window widths against 600mm truss spacing. If you are starting from the room rather than the roof, what size roof window do I need? is the better first read.
Two windows side by side, one per bay
When one narrow window is not enough light for the room, the usual answer is not a single wider window but two narrow ones, each in its own bay, with a truss running between them. Seen from inside, a pair like that reads as one generous opening split by a slim mullion of lined timber. Seen from outside, the manufacturers make combination flashing kits so that the two frames share one neatly weathered unit on the slope.
Two windows side by side usually give more daylight than you might expect, because together they cover more glass area than a single window of the narrow size, and they spread the light across the room. They also leave the structure exactly as it was designed. The same idea extends upwards: a window in the same bay above another, or a row along a long slope, as long as each one stays inside its own gap between trusses.
There are practical limits, such as how close to the ridge or the eaves a frame can go, and the flashing layout for the pair. We cover those in the answer to can two roof windows be fitted side by side?
When a wider opening needs designed trimming
Sometimes a single wide window really is the right choice. A loft conversion may need an escape window of a certain size, or a room may be laid out around one large frame. In a trussed roof, that means at least one truss has to be interrupted, and that is structural work that needs to be designed.
The design usually comes from a structural engineer, or from the truss manufacturer if the roof is recent enough for them to have the original details. It will set out how the load from the cut truss is picked up and carried to the trusses either side. Often that means strengthening those neighbouring trusses and fitting trimmers with proper hangers, all sized by calculation for that roof. Building Control will want to see the design, and the work is inspected against it.
None of that is unusual or alarming. It simply moves the job from a between-the-trusses fit to a designed opening, with more time and cost attached. Our guide on when a wider roof window needs designed trimming explains how that process runs, and does a roof window need a structural engineer? answers when you need one and when you do not.
In a trussed roof the window is sized to the roof, not the roof to the window.
What the survey measures
Everything above is general. Your own roof decides the answer, which is why we survey the roof before we quote. The survey is short, but it is where the fit is settled, and it follows the same order every time.
- Roof type. We confirm from the loft whether the slope is trussed, cut or a mix, and note the truss pattern and the bracing positions.
- Truss centres. We measure the actual spacing and the clear gap at the point where the window would go, because spacing can drift slightly along a roof.
- Pitch and covering. We check the slope angle against the window range and identify the tiles or slate, which sets the flashing type.
- Obstructions. We look for bracing, water tanks, cables, vent pipes and insulation that sit where the opening would be.
- The room below. We look at ceiling heights, the head height you want, and where the light needs to land, so the window height suits the room.
- The written quote. We give you a specification that says whether the window fits between the trusses or needs a designed opening, and why.
Once a between-the-trusses window is agreed, the fitting is usually a straightforward job. If the survey shows a wider opening is the only way to get what you want, you hear that at the survey, with the design step explained, rather than on the day of fitting.
Flashing and linings, in brief
A window can fit the structure perfectly and still look or perform badly if the outside and inside finishes are rushed. On the outside, the flashing is what makes the frame weathertight against the roof covering. It has to match the covering: the profiled concrete tiles common on estate roofs need a different flashing from flat clay tiles or slate. Our guide to roof window flashings for concrete tiles, clay tiles and slate goes through the options.
On the inside, the lining is what turns a hole in the ceiling into a finished window. In a trussed roof the reveal is shaped by the trusses either side, so the sides of the lining usually run straight up against them, while the head and sill can be angled to spread the daylight further into the room. Insulation and a vapour control layer go in around the frame before the plasterboard. The details are in linings, reveals and making a roof window look finished inside.

Planning and Building Control, in brief
Two separate questions come up on almost every enquiry, and they are easy to confuse. Planning permission is about how the house looks and how it affects neighbours. Building Regulations are about how the work is built: the structure, the insulation and, in a loft room, the means of escape.
On planning, many roof windows on ordinary houses fall within permitted development, subject to conditions about how far the window projects from the roof and where it sits. Conservation areas, listed buildings and Article 4 directions change that picture, and front slopes are looked at more closely. The detail is in do roof windows need planning permission?
On Building Regulations, adding a new roof window is building work, and where it alters the structure the case is clear. We handle the Building Control notification where the work is notifiable, and a designed opening comes with the engineer's details to go with it. For the full explanation, read do roof windows need Building Regulations approval?
Loft conversions on trussed roofs
A roof window in an existing loft used for storage, or in the sloping ceiling of a room that is already there, is one job. Converting a trussed loft into a room is another. The W webs that fill the loft are exactly what a conversion has to remove, so a trussed loft conversion is a whole structural redesign of the roof, usually with new steel or timber members taking over from the webs. The roof windows are specified as part of that design, not added afterwards.
That is good news for the windows, because the new structure can be laid out with the openings in mind. It is also why it pays to decide on the windows early, while the engineer is still drawing. Our guide to roof windows for a loft conversion on an estate house walks through the order of decisions.
Getting the fit right on your roof
Most estate roofs around Basingstoke are trussed, and a great many rooflight ideas can be met between the trusses: a narrow window, a taller window, or a pair side by side. A smaller number really do need a wider frame, and those go through a designed opening with the drawings in place first. What should never happen is a skylight that gets its size from a brochure and then has the roof cut to suit.
If you want to see how we approach the whole job, from the survey to the finished lining, our roof window installation service sets it out, including our 10-year workmanship guarantee. You can see the full set of guides and answers on the same topic from the roof window installation page. When you are ready, book a roof survey and we will measure your trusses, tell you what fits, and put it in writing.