VELUX window installation in Basingstoke
VELUX windows sized to your truss spacing, flashed for your tiles or slate, and fitted with a 10-year workmanship guarantee.
Will a VELUX fit between my trusses?
Estate homes around Basingstoke mostly have trussed rafter roofs with trusses at 600mm centres. The VELUX width you choose decides whether the window sits in the gap between two trusses or needs a designed opening. Here is how the common choices compare, and the survey then confirms the spacing on your own roof.
| C width VELUX: fits between trusses | Made for the gap between two trusses at 600mm centres, so the roof structure stays exactly as designed. |
|---|---|
| Taller C width: same bay, more light | The extra length runs up the slope, giving a better view with no trimming at all. |
| Two C width windows: one per bay | Each window sits in its own bay with the truss between them left whole. |
| M width or wider: needs designed trimming | The opening crosses a truss, so the trimming is designed first and fitted to that specification. |
How it works
VELUX windows in Basingstoke
Look up at the frame of the roof window in almost any converted loft around Basingstoke and there is a small plate on it with a string of letters and numbers. That code tells you the maker, the model, the size and roughly when it was made, and on most estate houses the maker is VELUX. The name has become the everyday word for a roof window, the way people say a hoover for a vacuum cleaner, but a VELUX is a specific product range with its own sizes, flashings, glazing and accessories. Fitting one well means matching that range to the roof it goes into.
This page is about VELUX windows in particular: reading the code, the sizes that sit between the trussed rafters of an estate roof, the models and how they open, the flashing for your tiles or slate, what happens on the day, Building Control and planning, and what decides the cost. We survey the roof before we quote, we handle the Building Control notification, and every VELUX window we fit carries a 10-year workmanship guarantee. If you would like someone to look at the roof with you, book a roof survey.
Reading the code on a VELUX window
Every VELUX window carries a data plate, usually on the top of the sash or the frame, visible when the window is open. It is the single most useful piece of information when you are replacing a window, adding a matching one next to it, or ordering a blind. The code is made of a few parts, and once you know what each part does you can read most of them at a glance.
- The type code. Three letters such as GGL, GGU, GPL or GPU. The first letters describe the kind of window, and the last letter tells you the finish. GGL is the familiar centre pivot window in white painted pine; GGU is the same centre pivot action in a white polyurethane finish. GPL and GPU are the top hung and pivot versions that open outwards from the top.
- The size code. Two letters and two digits, such as CK04, MK06 or SK06. The letters set the width and the digits set the height. It is the part that matters most on a trussed roof, because the width decides whether the window fits between two trusses.
- The extra digits. A number after the size code, such as 0070 or 0066, describes the glazing and the generation of the window. Older windows carry an older style of size code, often a number or a letter and number together, which the current range still maps onto.
If the plate has worn away, the window can still be identified from its outside frame measurements, which is one of the things we do at a survey. What does the code on a VELUX window mean? decodes the plate in more detail, and what is the difference between VELUX GGL and GGU? explains the finish letters, which matter more than they look in a bathroom or kitchen.
People search for a skylight, builders say rooflight or roof window, and in everyday speech a roof window is often just called a Velux. On a pitched tiled roof those words usually describe the same thing: a glazed window set into the slope that opens or stays fixed. For the wider range of rooflight installation around Basingstoke, including flat roofs and lanterns, the homepage is the place to start. For roof windows from any maker, our roof window installation page covers the same ground without a brand in mind.
VELUX sizes that fit between 600mm trusses
Most houses on the estates around Basingstoke, from Popley and Oakridge through Brighton Hill and Winklebury to Chineham and Hatch Warren, were built on trussed rafter roofs. The trusses are factory made and laid out to a set spacing, most often 600mm centres, and each one is part of an engineered whole. The clear gap between two trusses at that spacing is 600mm less the thickness of the timber, and that gap decides which VELUX windows go in without touching the structure.
VELUX makes a width for exactly this situation. The C width, as in CK02 and CK04, has an outside frame width of 55cm, and it is designed to sit between rafters or trusses at 600mm centres with room for its brackets and insulation collar. Every wider size meets at least one truss. The table below sets out the widths you will see in a VELUX brochure against a roof with trusses at 600mm centres.
| VELUX width | Against 600mm truss centres | What it means for the roof |
|---|---|---|
| C width (CK02, CK04, CK06) | Sits in the clear gap between two trusses | No structural change. The trusses stay whole and the window fixes alongside them |
| Two C width windows side by side | One window in each neighbouring bay, the truss between them left whole | More glass without cutting a truss. The truss reads as a slim divider inside |
| F width (FK06, FK08) | Wider than the clear gap, so the opening meets a truss | A designed opening, with the truss trimmed to a specification |
| M width (MK04, MK06, MK08) | Crosses a truss | A designed opening. Common in loft conversions where the roof is redesigned anyway |
| P, S and U widths | Span more than one bay | A designed opening with more than one truss affected. Right for some rooms, never a default |
VELUX sizes that fit between 600mm trusses goes through each size code with the frame measurements and the heights available in the narrow width. If you just want the list of standard sizes, what are the standard VELUX window sizes? gives it in one place. The C width is not only for small windows: it comes in several heights, so a taller window in the same bay can give a lot more light and a much better view without any trimming.
The rule: a trussed rafter is never cut on judgement to make room for a wider VELUX. Each truss carries load as part of a designed set, and removing a section changes how that load travels.
The exception: a truss can be trimmed where the opening has been designed, by an engineer or the truss designer, with the trusses either side strengthened and trimmers sized to suit. The Building Control notification covers that work.
The strengthening usually means doubling the trusses or rafters either side of the opening. Do I need to double up rafters for a VELUX window? explains when that applies and what it involves. Cut rafter roofs in the older villages, such as Old Basing, Sherborne St John or Overton, have their own spacing, often closer and less regular than a trussed roof, so the survey measures every bay we plan to use rather than assuming.

Choosing the right VELUX size for the room
Once you know which widths suit the roof, the size question becomes about the room. The height of the window matters as much as the width, because it decides what you see from it. A VELUX in a shallow roof lies closer to flat, so it needs to be longer to give the same view out as a shorter window in a steeper roof. Estate house types vary in pitch, which is why two identical windows on neighbouring streets can feel quite different inside.
For a room you sit or work in, the aim is a window whose bottom edge lets you see out when seated and whose top edge lets you see the sky when standing, with the frame kept out of your eyeline. For a landing or stairwell, light and reach matter more than the view, and a fixed or remote-operated window often makes sense. VELUX sizes: choosing the right one for your roof walks through the room, the pitch and the floor level together, and it is the best place to start if you have a room in mind but no size.
One large window or several narrow ones
Two or three narrow windows in neighbouring bays can give close to the glass area of one large window while every truss stays whole. They can also be set one above the other on a tall slope, which gives both a view from a chair and light from high up. Can VELUX windows be fitted in a row or stacked? covers the combination flashings that join them into one weatherproof unit.
At the other end, a single large VELUX suits a room where one broad pane frames a view, or a stair that needs light to fall two floors. What is the largest VELUX roof window? explains the biggest standard sizes and what a roof needs to take them. Whatever the size, the roof has to be steep enough for the chosen model, and how shallow a roof can a VELUX go in? explains how the minimum pitch works and what the options are on a shallow slope.
VELUX models and how they open
The VELUX range is built around a few ways of opening, each suited to a different room. Choosing the opening type at the survey, rather than after the window arrives, avoids the common mismatch of a window that clashes with furniture or cannot be reached.
| Model | How it opens | Where it suits |
|---|---|---|
| Centre pivot (GGL, GGU) | Turns on a hinge halfway down the frame; the sash can be turned right round for cleaning from inside | Rooms with furniture under the window, and higher positions where a handle at the top is easy to reach |
| Top hung (GPL, GPU) | Opens outwards from a hinge at the top, leaving the opening clear | Low positions where you want to lean out and see the view, and loft rooms that need an escape window |
| CABRIO balcony | Top sash opens up, lower sash opens out and forms a small balcony with railings | Loft rooms where the slope is long enough and the room gains from standing space in the open air |
| Fixed | Does not open | Stairwells, landings and high positions where ventilation comes from elsewhere |
Choosing between VELUX top hung and centre pivot compares the two main types in more detail, including how each behaves with a blind fitted and how each sits against a sloping ceiling. If you are converting a loft and want a window that opens into a balcony, VELUX CABRIO balcony windows on a loft conversion covers the roof length, the structure and the planning questions.
A loft bedroom needs a way out in a fire, and a roof window can serve as that escape route if it is the right size and at the right height from the floor. The top hung models are made with this in mind. Can a VELUX be used as an escape window? explains what the Building Regulations look for and how the window is placed to meet them.
The finish matters too. The painted pine models look warm and suit most rooms. The white polyurethane models have a moulded surface over the timber core that copes better with steam and needs little upkeep, which is why they are the usual choice over a bath or shower. Is a VELUX suitable over a shower or bath? explains why, and what else to think about with water close to the glass.
Glazing, electric operation and blinds
Every new VELUX window meets the current Building Regulations for heat loss, so even the standard glazing is a big step up from an older timber roof window or a plastic dome. Beyond that, the range offers glazing for different priorities: better insulation, less noise from rain and road, or less heat gain on a south-facing slope. The inner pane on overhead glazing is laminated, so if it is ever broken the glass stays in the frame. VELUX glazing options for comfort, energy and noise sets out the choices and which rooms they suit.
Condensation on a roof window is usually a sign of warm, moist air meeting a cool surface rather than a fault with the window, and the way the lining is shaped plays a big part in it. Why does condensation form on a VELUX? explains the causes and how ventilation, glazing and linings reduce it.
INTEGRA electric and solar windows
Windows out of reach can be opened with a rod, but on a high landing or above a stair a powered window is far more practical. The VELUX INTEGRA range comes in electric versions, wired to the mains, and solar versions, which charge a small battery from a panel on the frame and need no cable. Both come with a rain sensor that closes the window when rain starts, and both can be run from a wall switch or a remote. VELUX INTEGRA electric and solar windows compares the two, and can a manual VELUX be made electric? explains the conversion kits for a window you already have.
If you want powered opening on a flat roof or a larger opening rooflight rather than a pitched roof window, the same survey covers electric flat roof rooflights too, and the homepage lists every type of skylight installation around Basingstoke.
Blinds and shutters
Blinds are worth deciding with the window rather than after, because the size code on the window decides which blinds fit, and some are best fitted before the lining is finished. Blackout blinds suit bedrooms, pleated and roller blinds soften the light, and an external awning blind or shutter cuts heat before it reaches the glass, which makes a real difference in a loft room in summer. VELUX blinds and shutters for heat and blackout explains each type and how they combine.

VELUX windows in estate lofts and new build roofs
On an estate house, a VELUX usually goes in as part of a loft conversion, and the estate house types built from the 1960s onward share a few traits. Their trussed rafter roofs have diagonal webs running across the loft, which is why the loft feels crowded before conversion. A conversion usually replaces or reinforces that structure with a new design, often with steel or new timbers, and the windows should be planned into that design from the start rather than added once the roof is altered.
Basingstoke grew from a market town into a London overspill town from the 1960s, and it carried on growing through Popley, Oakridge, South Ham, Brighton Hill, Winklebury, Hatch Warren, Chineham, Beggarwood, Kempshott and Lychpit, and now Manydown. Much of that housing was built by volume housebuilders to repeated house types, on trussed rafter roofs. The house type on your street is often the best clue to what is above your ceiling and which VELUX sizes suit it.
VELUX windows in an estate house loft conversion covers layout, headroom, window positions around a new staircase, and how the conversion design and the window sizes are settled together. For a loft that is only boarded and used for storage, a single C width window in one bay can bring light in without any structural change at all.
On newer houses, it is natural to be wary of cutting into a roof that is only a few years old. The same principles apply: a narrow window between the trusses leaves the roof exactly as designed, and a wider one needs a designed opening. The newest homes may still be under a housebuilder warranty, so check what yours says about alterations before any work goes ahead. Can a VELUX go into a new build roof? explains what to check first.
How we install a VELUX window
A VELUX window in a tiled or slate roof is fitted mostly from outside, from a scaffold or a roof ladder depending on height and access. Inside, the work is limited to the opening and its lining, and the room below is protected throughout. Here is the order of the job for a typical window going into an estate roof.
- Survey and specification. Before the quote we measure the truss or rafter spacing where the window will go, check the pitch and the roof covering, look at what sits inside the loft around the opening, and agree the model, size, position and extras with you.
- Order the right parts. The window, the flashing to suit your tiles or slate, the insulation and underlay collars, and any blinds or lining kit are ordered to the size code agreed at the survey.
- Access and protection. Scaffold or roof access goes up where needed. Inside, floors and furniture are covered and the room below the opening is sealed off, because cutting a ceiling makes dust.
- Open the roof. Tiles or slates around the window position are lifted and set aside for reuse. Battens and underlay are cut back to the opening size, leaving enough underlay to dress into the new frame.
- Frame the opening. For a C width window between trusses, trimmers are fixed between the trusses at the top and bottom of the opening and the trusses themselves are left alone. Where the design calls for a wider opening, the strengthening and trimming follow that design exactly.
- Fix the frame. The frame goes onto its brackets at the depth set by the flashing type, and it is checked for square, level and even gaps so the sash closes properly.
- Collars and flashing. The insulation collar goes round the frame, the underlay collar is dressed into its drainage gutter, and the flashing is fitted piece by piece, from the bottom up.
- Relay the roof. Tiles or slates are relaid round the flashing, cut where needed, so the roof looks as it did apart from the new window.
- Line the inside. A vapour barrier is fixed to the frame, then the reveals are formed and boarded ready for decoration, or a factory lining kit is fitted.
- Hand over. We check the window opens and closes evenly, show you how to use and clean it, complete the Building Control notification and take away everything we brought.
The time on site depends on the number of windows, whether any trimming is designed in, the access, and how much finishing is included inside. How long does fitting a VELUX take? gives the typical picture for a single window and for a loft set. The question of who should fit a roof window is a fair one, and can a roofer fit a VELUX window? looks at the skills the job draws on, from roofing to carpentry to plastering, and why the survey matters whoever does it.
Flashing, recessed fitting and the roof covering
The glass keeps weather out of the window; the flashing keeps it out of the roof. A VELUX flashing is a kit of shaped aluminium pieces that fits round the frame and laps under the tiles above and over the tiles below, so rainwater running down the slope is guided round the window. Each roof covering has its own flashing, and choosing the right one at the survey is what makes an installation last. VELUX makes flashings for profiled tiles, for flat materials such as slate and plain tiles, and for recessed installations.
| Roof covering | Where you find it | How the flashing works |
|---|---|---|
| Concrete interlocking tiles | Estate houses across Basingstoke's post-war and later estates | A tile flashing with a flexible pleated apron at the bottom, dressed down over the tile profile below the window |
| Plain clay tiles | Older houses in the villages and market towns, and some newer houses built to match | A flashing with soakers laid in with each tile course up the sides of the window |
| Natural slate | Victorian and Edwardian terraces in Reading, Caversham and Aldershot, and some village houses | A low profile slate flashing so the slates close up neatly against the frame |
| Recessed fitting | Conservation areas and any roof where a flatter look matters | The frame sits lower in the roof, with a matching recessed flashing, so the glass lines up more closely with the tiles or slate |
VELUX flashing types for tiles, slates and recessed fitting explains each flashing, how to tell which you need from the roof covering, and the combination flashings for windows in pairs or stacks. Slate needs particular care because the material is thin and brittle at the edges; can a VELUX be fitted in a slate roof? covers how it is cut and laid round the frame.
The rule: a VELUX window is set into the roof at the standard depth that its flashing is designed for, which leaves the frame sitting slightly proud of the tiles.
The exception: a recessed installation sets the frame deeper, so it sits closer to the line of the roof. It needs the matching recessed flashing and more careful work round the frame, and it suits conservation areas and front slopes where the look of the roof matters.
Recessed fitting also changes the lining inside, because the frame sits deeper in the roof. Recessed installation, linings and the VELUX finish inside covers both halves of that job, including how splayed reveals spread the light into the room. Flat roofs are a different case: a VELUX roof window is made for a pitched roof, and the brand makes separate flat roof products. Can a VELUX go on a flat roof? explains the options.

Conservation windows and upgrading an old VELUX
In the conservation areas of Old Basing, Kingsclere, Overton, Hartley Wintney, Odiham and Whitchurch, the look of the roof carries more weight, and the council will pay attention to anything that changes it. The VELUX conservation window is designed for these roofs: a slim black or dark grey exterior, a vertical glazing bar dividing the glass in the manner of a traditional cast iron rooflight, and a recessed installation so the window sits low among the tiles or slate. The VELUX conservation window and where it fits explains where it suits and where a specialist conservation rooflight may be the better match. Our conservation rooflight installation page covers those in full.
Upgrading an older VELUX in the same opening
An older VELUX from an earlier loft conversion may now be due for replacement: the glass may have misted, the timber finish has worn, or the handles and hinges have become stiff. VELUX designs its current windows to fit the openings of its older sizes, so an older window can usually be swapped for a current model without reshaping the opening, and the new window brings current glazing and a fresh flashing. Upgrading an old VELUX to a current model in the same opening explains how the old size codes map to the new ones and what changes on the day.
Replacing a roof window in the same opening is usually a shorter job than fitting a new one, because the structure is already formed. The survey still checks the timbers round the frame, the underlay and the lining, so the new window goes into a sound opening. For rooflights of any kind that have misted or failed, including flat roof units and domes, our misted and failed rooflight replacement page is the place to look.
Building Control, planning and paperwork
Adding a new VELUX window is building work under the Building Regulations. It changes the roof structure, even where the trusses stay whole, and it changes the insulated envelope of the house, so it has to meet the rules for structure, heat loss and, in a bedroom, means of escape. The Building Control notification records that the work meets them. We handle the notification for you, and you receive the completion paperwork, which matters when you come to sell.
FENSA is one of the competent person schemes for replacement windows and doors in walls, and a Building Control notification is the other route to show that work meets the Building Regulations. How that applies to a roof window, new or replacement, is explained in is a FENSA certificate needed for a VELUX window?. The practical point for you is to keep the completion paperwork with the house deeds.
Planning permission is a separate question from Building Regulations. For a house, roof windows are generally covered by permitted development rights for roof alterations, provided the window does not project more than 150mm beyond the plane of the roof slope, sits no higher than the highest part of the roof, and meets the conditions on side-facing windows. Flats and maisonettes do not have those rights, and listed buildings need listed building consent.
The rule: a VELUX window on the rear slope of an ordinary house usually falls within permitted development, and a standard installation keeps well inside the projection limit.
The exception: conservation areas may have an Article 4 direction removing those rights, some estates had them removed by a condition when they were built, and a front slope facing the street draws more attention. Where permission is needed, the application is assessed on merit, and nobody can promise the outcome in advance.
Do VELUX windows need planning permission? gives the short answer and the checks to make with Basingstoke and Deane Borough Council, Hart District Council or whichever council covers your house. We raise these questions at the survey so they are settled before you commit.
What decides the cost, and the survey
Two VELUX windows with the same size code can be very different jobs, so the price comes from the survey rather than from a list. What we can set out here is what moves the cost, so the written quote makes sense when it arrives. How much does it cost to fit a VELUX window? covers the same factors in a shorter form.
- Size and structure. A C width window between trusses is the simplest job. A designed opening adds the design, the extra timber and the time to fit it.
- The model. Centre pivot or top hung, pine or polyurethane finish, the glazing chosen, and manual, electric or solar operation.
- The roof covering. Concrete tiles, plain clay tiles and slate each need their own flashing and a different amount of cutting and relaying. Recessed fitting takes longer than standard.
- Access. Whether a scaffold is needed, the height of the roof, and how easily the slope can be reached from the ground.
- Number of windows. Several windows on one slope share the access and set-up, so a set fitted together is often better value than separate visits.
- The inside. A short lining in a loft room is quick; a light shaft through a loft to a landing, plastering and decorating all add time.
- Extras. Blinds, awnings, rain sensors and any electrical connection for a powered window.
The survey is where all of that is settled. We look at the roof from outside and from the loft, measure the spacing where the window will go, check the pitch and the covering, read the data plate on any existing VELUX, and talk through how you want to use the room. We tell you which sizes fit without trimming, whether your idea needs a designed opening, and whether planning or a warranty needs checking first. The written quote follows from what we found on your roof.
It is worth weighing up the downsides as well. Roof windows let in more light than a wall window of the same size, which also means more heat in summer and more rain noise, both of which the right glazing and blinds reduce. What are the disadvantages of VELUX windows? gives a fair account of each, so you can decide with the full picture.
Every VELUX window we install carries our 10-year workmanship guarantee. It covers the fitting work we carry out, it comes from us directly, and it is not insurance backed. The window itself comes with its manufacturer's product guarantee, and we give you the details of both at handover.
If you have a VELUX window in mind, a skylight you want in a dark room, or an old roof window you would like upgraded, book a roof survey. You can also call 01256 213206. We will tell you what fits your roof and why before we ask you to commit to anything.
How a job runs
Roof survey
We inspect your roof and recommend what will fit and perform.
Installation
Our team installs with care, keeping your home protected.
Sign-off and guarantee
We complete the sign-off and issue your 10-year workmanship guarantee.
VELUX window guides
-
VELUX sizes
-
VELUX sizes that fit between 600mm trusses
-
VELUX flashing types for tiles, slates and recessed fitting
-
VELUX glazing options for comfort, energy and noise
-
VELUX windows in an estate house loft conversion
-
The VELUX conservation window and where it fits
More guides
- VELUX INTEGRA electric and solar windows
- VELUX CABRIO balcony windows on a loft conversion
- Choosing between VELUX top hung and centre pivot
- Recessed installation, linings and the VELUX finish inside
- Upgrading an old VELUX to a current model in the same opening
- VELUX blinds and shutters for heat and blackout
Questions answered
- What does the code on a VELUX window mean?
- What are the standard VELUX window sizes?
- Do VELUX windows need planning permission?
- How shallow a roof can a VELUX go in?
- Can a manual VELUX be made electric?
- How long does fitting a VELUX take?
- What is the difference between VELUX GGL and GGU?
- Can a VELUX go on a flat roof?
- Why does condensation form on a VELUX?
- How much does it cost to fit a VELUX window?
- Is a VELUX suitable over a shower or bath?
- Can a VELUX go into a new build roof?
- Do I need to double up rafters for a VELUX window?
- Can VELUX windows be fitted in a row or stacked?
- Can a VELUX be fitted in a slate roof?
- Is a FENSA certificate needed for a VELUX window?
- Can a VELUX be used as an escape window?
- What are the disadvantages of VELUX windows?
- Can a roofer fit a VELUX window?
- What is the largest VELUX roof window?
Frequently asked questions
What VELUX size fits between 600mm trusses?
The C width, as in CK02, CK04 and CK06, is made to sit between trusses or rafters at 600mm centres with no structural change. It comes in several heights, so a taller window gives more light in the same bay. VELUX sizes that fit between 600mm trusses lists them.
Can a manual VELUX be made electric?
Often, yes. VELUX makes conversion kits that add an electric or solar motor to many existing manual windows, depending on the model and its age. The data plate on the window tells you which kit suits. Can a manual VELUX be made electric? explains how to check.
Do VELUX windows need planning permission?
Usually not for a house, because roof windows generally fall within permitted development when they sit close to the roof slope and below the ridge. Conservation areas, front slopes, flats and listed buildings can change that, and any application is assessed on merit. Do VELUX windows need planning permission? sets out the checks.
Can an old VELUX be replaced without changing the opening?
In most cases, yes. Current VELUX windows are made to fit the openings of the older sizes, so the old window comes out and a current model goes into the same opening with a new flashing. Upgrading an old VELUX to a current model explains how the size codes match up.
Which is better over a bathroom, GGL or GGU?
GGU, the white polyurethane finish, is the usual choice in a bathroom or kitchen, because its moulded surface copes well with steam and needs little upkeep. GGL, in painted pine, suits most other rooms. What is the difference between VELUX GGL and GGU? compares them.

Free roof survey
Tell us about your roof
- Survey before any quote
- No obligation
- Plain-English advice
Say what you have in mind and where. We survey the roof before we quote, then tell you plainly what fits.