GuideVELUX windows

VELUX sizes: choosing the right one for your roof

How to read a VELUX size code and pick a width the roof allows and a height that suits the pitch, the room and your reach.

A blackout blind fitted to a roof window
A blackout blind fitted to a roof window

A VELUX size gets chosen twice. The room chooses first: it wants a certain amount of daylight, a view out at a sensible height and a handle you can reach. The roof chooses second, and on a house built around Basingstoke in the last sixty years it usually has the final word, because the width of the opening is fixed by the timbers either side of it. The brochure hides all of that behind a grid of letters and numbers. This guide turns the grid into a decision you can make before anyone climbs a ladder.

Everything here applies to a pitched roof covered in tiles or slate. If you are still deciding between makers, or wondering whether a roof window is the right kind of rooflight at all, the VELUX window installation page sets out the whole service first.

What the letters and numbers on a VELUX size mean

Every current VELUX size code is two letters and two digits, such as MK06. The first letter is the width, the K marks the current generation of frame sizes, and the two digits are the height. Read that way, CK04 is the narrowest width at a middling height, and SK08 is a wide, tall window. The code sits on the data plate inside the sash along with the type letters (GGL, GPU and so on), and what the code on a VELUX window means walks through the whole plate if you are looking at one now.

The measurements below are the outside frame sizes, which is the figure that matters on the roof. The glass you see from the room is smaller, and the hole in the ceiling depends on how the lining is shaped.

VELUX width letters and what each one means on a 600mm trussed roof
Width letterOutside frame widthAgainst trusses at 600mm centres
C (CK02, CK04, CK06)55cmDrops into the clear gap between two trusses; nothing structural is cut
F (FK06, FK08)66cmWider than the gap; one truss is interrupted, so the trimming must be designed
M (MK04, MK06, MK08, MK10)78cmMeets a truss; a designed opening
P (PK08, PK10)94cmMeets a truss; a designed opening
S (SK06, SK08)114cmSpans more than one gap; a designed opening, usually drawn by an engineer
U (UK04, UK08)134cmSpans more than one gap; a designed opening, usually drawn by an engineer

The height digits run in steps: 01 is 70cm, 02 is 78cm, 04 is 98cm, 06 is 118cm, 08 is 140cm and 10 is 160cm. Not every width is made in every height, so a size that looks sensible on paper may not exist. The list of common codes, and which pairs of width and height are actually on sale, is kept in what are the standard VELUX window sizes?

Sizing a roof window to the truss bays On the left, a section through a pitched roof built from Fink trussed rafters, with W-shaped webs joined by nail plates, tiles on battens, and a roof window set in the slope. On the right, the same slope seen square-on: trusses at even 600mm centres with a narrow roof window sitting in the bay between two of them, so no truss is cut. A wider window outline, drawn dashed, crosses a truss and would need designed trimming. Section600mm centresSeen square-on12345678

Sizing a roof window to the truss bays

  1. Fink trussed rafter, factory made and designed to work as one whole frame
  2. W-shaped webs, joined at every node by pressed metal nail plates
  3. Tile covering on battens over the underlay
  4. Roof window set in the slope, fitted between trusses so the frame is untouched
  5. Narrow roof window sitting in the bay between two trusses
  6. Trusses at even 600mm centres along the roof
  7. No truss cut: the trusses either side of the window stay whole
  8. A wider window crosses a truss, so the cut needs designed trimming from an engineer or the truss maker

Width is the roof's decision

Look up through the loft hatch of a house in Popley, Brighton Hill or Chineham and you will usually find trussed rafters: factory-made triangles of timber, set at 600mm centres and braced together as one engineered roof. Take the thickness of a truss away from that spacing and what is left is the clear gap. The C width was made for it. A CK window sits in that gap with room for its brackets and insulation, and the trusses either side stay exactly as they were delivered.

The rule: on a trussed estate roof, start with the C width and change it only for a reason. The exception is a room that genuinely needs one wider frame, such as a loft bedroom whose escape window must be larger; then the truss that is in the way gets designed trimming, specified on paper before the tiles come off.

Older houses change the arithmetic. A Victorian terrace in Reading or a cottage in Old Basing has cut rafters, often at closer and less regular spacing, and the width that fits is whatever the measured gap allows. Some of those roofs take a rafter being trimmed quite happily, with the load carried on trimmers; others need thought. The full treatment of the between-the-trusses question, with the edge cases, is in VELUX sizes that fit between 600mm trusses.

Height is the pitch's decision

Once the width is settled, the height is where you have real choice, and the angle of the roof is what should guide it. A roof window sits in the plane of the slope. On a steep roof the glass stands fairly upright, so even a shorter window gives a decent vertical slice of view. On a shallow roof the same window lies back towards the sky: you get plenty of daylight but see mostly clouds unless you stand right underneath it.

So the flatter the slope, the taller the window you want to get a view out, and the steeper the slope, the more a shorter frame will do. A CK06 on a low-pitched bungalow roof can give a far better outlook than a CK04 in the same spot. Pitch also sets the limits of what can go in at all: every VELUX has a minimum pitch, and the flashing has its own range. If your roof is shallow, how shallow a roof a VELUX can go in gives the direct answer.

Tall narrow roof window in a shallow sloping ceiling above a bed, framing sky and treetops
On a lower pitch a taller frame brings the view back down to eye level

The room decides where the frame sits

Height is also about people. Stand in the room and picture three lines on the sloping ceiling: where your eyes are when you stand, where they are when you sit at a desk or lie in bed, and how high you can comfortably reach. The best size puts glass across the eye line you care about and keeps the handle within reach.

That handle is the detail people forget. A centre pivot VELUX has its control bar along the top of the sash. On a knee wall in a loft room that is perfect; set high up a tall slope it can end up out of reach without a pole or an electric motor. A top hung window is opened from a handle at the bottom and swings clear of your head, which suits a frame fitted low or one you want to lean out of. Which of the two suits your slope, and why, is covered in choosing between VELUX top hung and centre pivot.

A good test at home is to hold a tape against the ceiling slope and mark the top and bottom of the frame you are considering. It shows at once whether the bottom of a CK02 would leave you staring at plasterboard, or whether a CK06 would put the handle beyond your fingertips.

How much glass the room wants

Glass in the roof lets in more daylight than the same area of glass in a wall, because it faces the open sky rather than the houses opposite. That is why a modest skylight can transform a dark landing, and why a loft bedroom rarely needs the biggest frame in the range. Light also depends on where it lands: a window over the stairwell of a Hatch Warren semi lights the landing, the stairs and the hall below it, while the same frame over a wardrobe mostly lights a door.

For a room that feels dark, think about spreading the glass rather than enlarging one pane. Two narrow windows at either end of a long loft room light it more evenly than one wide frame in the middle, and on a trussed roof they avoid any structural change at all.

The best VELUX size is the one that suits the roof you have and the way you will stand in the room, not the largest one in the brochure.

Two narrow windows or one wide one

When one CK window is not enough, the next move on a trussed roof is usually a second CK in the next bay along, with a truss running between them. VELUX makes combination flashing kits so the pair shares one weathered unit outside, and from inside the truss reads as a slim lined mullion between two panes. Windows can also be stacked one above another in the same bay, which suits a tall slope where you want sky above and a view below.

A single wide frame still has its place. It gives an uninterrupted view, it can meet escape requirements that a narrow sash may struggle with, and on a cut rafter roof the trimming may be simple. The limits on pairs, rows and stacks are set out in can VELUX windows be fitted in a row or stacked?, and if you are wondering how far the range goes the other way, what is the largest VELUX roof window? has the answer.

Loft conversions: escape, headroom and the plan

A loft room used as a bedroom brings a rule that can override every preference above. Where the escape route relies on the window, Building Regulations set a minimum clear opening and a limit on how high the bottom of that opening can sit above the floor. A narrow centre pivot sash does not always give that clear opening, which is why escape windows on estate conversions are often a wider size or a top hung model chosen for the job. Can a VELUX be used as an escape window? explains how that is judged.

The good news is that in a trussed loft conversion the roof structure is being redesigned anyway, because the W webs that fill the loft have to go. That means the openings can be drawn into the new structure from the start, so a wider frame costs a line on the engineer's drawing rather than a change of plan later. VELUX windows in an estate house loft conversion sets out the order in which those decisions are made.

Swapping an old window for the same size

If there is already a VELUX in the roof, the size question may be answered for you. Older windows carry older size codes, but the current range maps onto them, so a like-for-like frame can go into the existing opening with the trimming, the battens and often the lining left as they are. That keeps the job small and the ceiling largely undisturbed.

Going up a size at the same time is possible, but it turns a straightforward swap into a new opening, with everything that means for the roof. Going down is rarely worth it. Upgrading an old VELUX to a current model in the same opening covers matching the old code and what changes with a newer frame.

Choosing a size in six moves

Put together, the choice runs in a fixed order. Doing it the other way round, by picking a window you like and then asking the roof to accept it, is how rooflight jobs grow expensive.

  1. Identify the roof. From the loft, decide whether the slope is trussed or cut, and measure the spacing where the window would go.
  2. Fix the width. On 600mm trusses that is the C width unless a reason, such as escape, points to a designed opening.
  3. Read the pitch. A shallow slope favours a taller frame; a steep one can use a shorter frame for the same view.
  4. Mark the room. Tape the top and bottom of the frame on the ceiling slope and check eye line and reach.
  5. Choose the opening type. Centre pivot for a knee wall, top hung for a low frame or an escape window, or electric where the handle would be out of reach.
  6. Decide one or two. If one narrow window is not enough light, add a second in the next bay before reaching for a wider size.
A new roof window fitted in an older tiled roof
Figure 2 A new roof window fitted in an older tiled roof

Where the survey comes in

You can get a long way with a torch and a tape, but the roof has the last say. Truss spacing drifts a little along a row, bracing and water tanks sit where you least want them, and the covering decides which flashing the chosen size will need. We survey the roof before we quote so the size you have in mind is checked against what is actually up there, and the written specification says whether it drops between the timbers or needs a designed opening.

Size is also one of the things that moves the price, along with the covering, access and whether trimming is involved; how much it costs to fit a VELUX window explains what shapes a quote without pretending to a figure. For flat roofs, lanterns and the wider range of skylight and rooflight work around the town, the homepage is the place to look. For the fitting itself, from flashing to finished reveal, and the 10-year workmanship guarantee that covers it, go back to our VELUX window service. Or skip the reading and ask us to measure your roof; you will leave the survey knowing the code that fits.

Free roof survey

Tell us about your roof

  • Survey before any quote
  • No obligation
  • Plain-English advice

Say what you have in mind and where. We survey the roof before we quote, then tell you plainly what fits.

Prefer to talk? 01256 213206

Request my survey