Question answered · VELUX windows

What are the standard VELUX window sizes?

The short answer

VELUX makes its pitched roof windows in a fixed grid of sizes, each named by a code such as CK04 or MK06. The letter sets the outside frame width, from 55cm (C) up to 134cm (U), and the two digits set the height, from 70cm (01) up to 160cm (10). Not every width comes in every height, and on a trussed estate roof only the C width sits between the trusses untouched.

A blackout blind fitted to a roof window

Those codes are what a brochure, a merchant and a fitter all use, so it helps to know how to read them before you settle on a skylight for a loft room or a dark landing. This page lists the common sizes and says what each one means for the roof above you. Our VELUX window installation page covers the wider service, from survey to the finished lining.

How a VELUX size code is put together

A current size code has four characters. The first is a letter for the width of the outside frame. The second is K, which marks the present generation of frame sizes. The last two are digits for the height of the frame measured up the slope. So MK08 reads as the M width at the 08 height, and CK02 is the narrowest width at a short height.

The size code is only part of what is printed on the data plate inside the sash. Type letters such as GGL or GGU come before it and tell you the opening style and the finish. If you are looking at a plate on an existing roof window right now, what the code on a VELUX means decodes the whole line, including the older numbering found on earlier frames.

Sizing a roof window to the truss bays On the left, a section through a pitched roof built from Fink trussed rafters, with W-shaped webs joined by nail plates, tiles on battens, and a roof window set in the slope. On the right, the same slope seen square-on: trusses at even 600mm centres with a narrow roof window sitting in the bay between two of them, so no truss is cut. A wider window outline, drawn dashed, crosses a truss and would need designed trimming. Section600mm centresSeen square-on12345678

Sizing a roof window to the truss bays

  1. Fink trussed rafter, factory made and designed to work as one whole frame
  2. W-shaped webs, joined at every node by pressed metal nail plates
  3. Tile covering on battens over the underlay
  4. Roof window set in the slope, fitted between trusses so the frame is untouched
  5. Narrow roof window sitting in the bay between two trusses
  6. Trusses at even 600mm centres along the roof
  7. No truss cut: the trusses either side of the window stay whole
  8. A wider window crosses a truss, so the cut needs designed trimming from an engineer or the truss maker

The common sizes, width by height

The table gives the outside frame dimensions, which is the figure that matters when the tiles come off. The glass you see from inside is smaller, and the finished hole in the ceiling depends on how the lining is shaped. The range changes from time to time and some sizes are made only in certain models, so treat the list as the common core rather than a catalogue.

Common VELUX pitched roof window sizes (outside frame, width by height)
Width letterFrame widthCodes and heights
C55cmCK01 (70cm), CK02 (78cm), CK04 (98cm), CK06 (118cm)
F66cmFK06 (118cm), FK08 (140cm)
M78cmMK04 (98cm), MK06 (118cm), MK08 (140cm), MK10 (160cm)
P94cmPK08 (140cm), PK10 (160cm)
S114cmSK06 (118cm), SK08 (140cm), SK10 (160cm)
U134cmUK04 (98cm), UK08 (140cm), UK10 (160cm)

The height digits keep the same meaning across every width: 01 is 70cm, 02 is 78cm, 04 is 98cm, 06 is 118cm, 08 is 140cm and 10 is 160cm. That consistency is useful. Once you know that 06 means 118cm, you can picture an FK06 or an SK06 on the slope without looking anything up. At the top of the grid sit the widest and tallest frames, and the largest VELUX roof window answer looks at when one of those is worth the structural work it brings.

Which widths go between 600mm trusses

Most houses on the estates around Basingstoke, from the Popley and Oakridge townhouses to a Hatch Warren semi, have trussed rafter roofs set out at 600mm centres. Take the thickness of a truss away from that spacing and the clear gap left is a little under 600mm. Of the six widths, only C fits inside it.

The rule: on a trussed roof at 600mm centres, the C width is the size that leaves every truss whole, and any wider letter from F upwards crosses a truss. The exception is a wider frame fitted through an opening that a structural engineer or the truss designer has drawn up first, with the trimming specified before anything is cut.

Cut rafter roofs in older houses, such as a terrace in Reading or a cottage in Old Basing, follow a different logic: the rafter spacing varies and the width that fits is whatever the measured gap allows. Our guide to VELUX sizes that fit between 600mm trusses works through the bay by bay detail, including bracing, water tanks and the gap drifting along a slope.

What the height gives you

Height runs up the slope, parallel to the timbers, so it never meets a truss. That makes it the free choice once the width is fixed, and it is where a narrow C width earns its place. A CK06 carries far more glass than a CK02 while sitting in exactly the same bay.

The pitch of the roof is the main guide. On a steep slope the frame stands fairly upright and even a shorter window gives a view out. On a shallow slope the glass lies back towards the sky, so a taller frame is needed to bring the horizon into sight from a standing position. Every model also has a lowest pitch it is made for, and how shallow a roof a VELUX can go in gives that limit in a few lines.

The room matters too. A tall frame on a high slope can put a centre pivot handle out of reach, while a short frame low on a knee wall might leave you looking at plasterboard. Marking the top and bottom of a frame on the sloping ceiling with a tape is a simple way to test a size before committing to it. The full decision, room first and roof second, is set out in the guide to choosing the right VELUX size.

Sizes when an old roof window is replaced

An older VELUX in a 1970s or 1980s estate house often carries a code from an earlier generation of sizes. Many of those older frames correspond to a current size, which lets a new window go into the same opening with the tiles, battens and lining disturbed as little as possible. Where the old frame has no direct match, the opening is adjusted to the nearest current size, and on a trussed roof that adjustment has to stay within the gap the trusses allow.

Reading the old plate before anything is ordered saves guesswork. If the plate is missing or unreadable, measuring the outside of the frame from the roof side settles it.

Confirming the size on your roof

A size chart tells you what exists; the roof tells you what will work. Before quoting we survey the roof in person, measuring the truss or rafter spacing at the exact bay you have in mind, the pitch, and the covering, whether concrete tile, clay tile or slate, so the flashing suits it. The outcome is a named code rather than a range of maybes.

  1. Measure the bay. The clear gap between the timbers where the rooflight would sit, not the figure on a drawing.
  2. Check the pitch. Against the minimum for the model and against the view you want from the room.
  3. Name the code. A C width between the trusses, two narrow frames side by side, or a wider frame with a designed opening.

Where a structural change is involved, the Building Control notification is part of the job and dealt with on your behalf, and the finished work is covered by a 10-year workmanship guarantee (not insurance backed). If you already have a code in mind, or just a room that needs more light, ask us to check it on your roof.

Free roof survey

Tell us about your roof

  • Survey before any quote
  • No obligation
  • Plain-English advice

Say what you have in mind and where. We survey the roof before we quote, then tell you plainly what fits.

Prefer to talk? 01256 213206