That is the planning side only. Building Regulations are a separate test, and a roof window almost always involves them. Both questions get settled during our VELUX window installation survey, but it helps to know which rules apply to your house before anyone talks sizes.
What follows walks through the permitted development conditions in plain terms, the situations that take a house outside them, and how to get certainty from the council when the position is unclear.
Permitted development: the conditions in plain words
Permitted development rights let a householder make certain changes without applying for consent. Roof alterations that are not extensions, which includes putting a roof window into an existing slope, are covered as long as a short list of limits is respected.
| Condition | What it means for a VELUX |
|---|---|
| Projection | The window may stand no more than 150mm proud of the roof plane. A standard flashed VELUX sits well inside that; a recessed fitting sits lower still. |
| Height | No part may rise above the highest point of the existing roof, so nothing breaks the ridge line. |
| Side elevations | A window on a slope facing a neighbour's side must be obscure glazed and fixed shut, unless the opening part is more than 1.7m above the floor of the room. |
| Type of property | The rights belong to houses. Flats and maisonettes do not have them. |
On a typical estate semi or terrace with a pitched tiled roof, a single roof window on the rear slope meets every one of those conditions. The detail that most often needs a second look is the side-facing slope on a detached house or the end of a terrace, where the privacy condition can decide the glazing and the opening type.
Sizing a roof window to the truss bays
- Fink trussed rafter, factory made and designed to work as one whole frame
- W-shaped webs, joined at every node by pressed metal nail plates
- Tile covering on battens over the underlay
- Roof window set in the slope, fitted between trusses so the frame is untouched
- Narrow roof window sitting in the bay between two trusses
- Trusses at even 600mm centres along the roof
- No truss cut: the trusses either side of the window stay whole
- A wider window crosses a truss, so the cut needs designed trimming from an engineer or the truss maker
When a VELUX does need planning permission
The general rule gives way in a handful of specific cases, and each one depends on the property rather than on the window.
- Flats and maisonettes. With no householder permitted development rights, any external change to the roof of a flat needs an application, and usually the freeholder's agreement too.
- Listed buildings. Listed building consent is needed for works affecting the building's character, and a new opening in a historic roof is plainly one of those.
- Article 4 directions. A council can withdraw specific rights in a defined area, often to protect the roofscape of a conservation area. Where one covers roof alterations, an application is needed.
- Removed rights on newer estates. The permission that approved an estate can carry a condition removing permitted development rights for its homes. It is worth reading the original consent, not assuming.
The rule: in a conservation area, a roof window on a house is still generally allowed under permitted development. The exception: an Article 4 direction may remove that right, typically for slopes that face a road, so the council's records decide it street by street.
Conservation areas and historic roofs around Basingstoke
The borough has conservation areas in its villages and older centres, including Old Basing, Kingsclere and Overton, and each has its own appraisal. Where a front slope is protected, the council looks at whether a proposal keeps the character of the roof, and a flush, slim-framed window generally sits better against old clay tile or slate than a standard profile. Consent is judged against those policies, never promised in advance.
Where a heritage roof is involved, the product choice and the paperwork tend to go together. Our guide to the VELUX conservation window explains the glazing bar, the low profile and the sizes, and that is the page that owns the detail. For a listed or protected building needing a heritage-grade rooflight in cast iron or steel, see conservation rooflight installation.
Houses across Basingstoke and Deane come under Basingstoke and Deane Borough Council as the planning authority. Its conservation area appraisals and any Article 4 directions are published by the council and are the place to check a specific address.
Planning versus Building Regulations
These two get confused because both involve the council, but they ask different things. Planning is about appearance and the effect on neighbours. Building Regulations are about how the work performs: the structure of the roof around the opening, the thermal performance of the new glazing, and, in a converted loft, fire escape. A skylight that needs no planning permission can still need Building Control, and on a trussed estate roof where a truss is to be altered, it certainly does.
The notification for a roof window is something our team takes on as part of the installation, so the paperwork lands with the council without you chasing it. How competent person schemes fit alongside that is set out in the answer on whether a FENSA certificate is needed for a VELUX.
How to check before any work starts
- Look at the property type. A house has permitted development rights to begin with; a flat or maisonette does not.
- Check listing and conservation status. The council's online maps show conservation area boundaries, and the national heritage list shows whether the building is listed.
- Check for restrictions. Ask the planning team whether an Article 4 direction applies, and read the planning consent for your estate for any condition removing rights.
- Get certainty if you want it. A Lawful Development Certificate confirms in writing that a proposal is permitted development, which is useful when a sale or remortgage is on the horizon.
On the newest estates there is one more document to read: a housebuilder warranty may set its own terms for alterations to the roof, so check it before booking. Our answer on fitting a VELUX into a new build roof covers that situation.
Infographic
Planning and Building Control: the questions in order
Is the house listed?
Yes: listed building consent is needed before any rooflight goes in.
No: next question.
Is it in a conservation area, or a flat or maisonette?
Yes: check with the council. A conservation-style rooflight is often the expected choice.
No: next question.
Will it sit within permitted development limits?
Usually yes when it projects no more than 150mm from the roof plane and stays below the highest part of the roof.
If not: a householder planning application.
Is the work notifiable under the Building Regulations?
A new rooflight, or a replacement that changes the structure, is. We notify Building Control for you.
Either way the glazing must meet current thermal standards.
Where the window goes on the roof
Position matters as much as permission. A rear slope is the usual choice for privacy and, on many estates, for the view over gardens rather than the street. If one window will not bring enough daylight, a pair side by side on the same slope stays within the same planning position; the layout options are in the answer on fitting VELUX windows in a row or stacked. The survey confirms which slope suits both the room and the rules, and whether the rooflight you have in mind sits between the trusses or needs a designed opening.
Want a straight answer for your own house? Arrange a survey and we will check the roof, the slope and the planning position together before you commit to anything.