GuideRoof windows

Roof windows as a means of escape in a loft room

What a roof window must be to serve as a means of escape from a loft room: clear opening, sill height, top hung sashes and fitting between trusses.

A loft study lit by a top-hung roof window
A loft study lit by a top-hung roof window

Picture the loft room at night with the door shut and smoke on the landing below. The stairs are the way out you planned for, but if they are not usable, the only other opening in that room is the window in the roof. Whether that window can do the job depends on decisions made long before anyone sleeps up there: its size, the way the sash moves, how high it sits above the floor and where it lands on the slope. This guide walks through what a roof window has to be if it is going to serve as a means of escape, when the rules actually ask for one, and how that fits with the trussed roofs found on so many houses around Basingstoke.

It is written for owners planning a room in the roof, and for anyone who has been told by a designer or a Building Control surveyor that the new bedroom "needs an escape window" and wants to know what that means in practice before a single tile comes off. It sits alongside the rest of our roof window fitting advice for estate and village homes.

Escape, rescue and what the window is really for

People use "escape window" loosely, so it helps to separate two ideas. A means of escape is a route a person can use on their own to get away from a fire. A rescue opening is somewhere a person can wait, get fresh air and be reached by the fire service with a ladder. A skylight in a pitched roof is rarely a place anyone climbs down from unaided; its value is as a reachable, openable gap in the roof where somebody can be seen and helped.

That distinction explains why the guidance cares so much about a clear opening and a sensible sill height. The occupant must be able to get to the window quickly in the dark, open it fully without tools or a separate key, and put head and shoulders through it. Everything else in this guide follows from those three needs.

An escape window is judged by the hole it leaves when it is open, not by the size printed on the box.

How rooflights and roof windows open Four side sections. A centre-pivot roof window whose sash turns about its middle, and a top-hung roof window whose sash swings out from a hinge at the top, both in a pitched roof. Below them a fixed flat rooflight that does not open, and an electric flat rooflight lifted on a chain actuator with a rain sensor on the frame. Centre-pivot Top-hung Fixed Electric 1234 5678

How rooflights and roof windows open

  1. Centre-pivot sash, turns so the lower edge tips out and the top swings in, handy for cleaning from inside
  2. Pivot point, the hinge line across the middle of the sash
  3. Top-hung sash, swings outward clear of the opening for a wider view
  4. Top hinge, where the sash is hung from the head of the frame
  5. Fixed rooflight, glazing sealed to the upstand with no moving parts
  6. Electric opening rooflight, the glazed lid lifts from one edge for ventilation
  7. Motorised chain actuator, pushes the lid open and draws it closed
  8. Rain sensor, closes the rooflight automatically when it starts to rain

When the rules ask for an escape window in a roof room

In England the guidance sits in Approved Document B (fire safety), Volume 1, which covers dwellings. Its approach depends on the height of the floor above the ground. For habitable rooms on a storey no more than 4.5m above ground level, an escape window (or a door to a suitable exit) is one of the accepted ways to provide a way out. Once a new storey sits above 4.5m, as the floor of a loft conversion on a typical two-storey house does, the expected answer is a protected stairway running down to a final exit, because a window that high is not treated as a safe way down.

The rule: a loft conversion on a two-storey house relies on a protected stair, with fire doors onto it, as its main escape route. The exception: where a room in the roof sits on a lower storey, for example a chalet bungalow or a room-in-roof first floor, the window itself may be the route the design depends on. Which case you are in is a question for the designer and the Building Control body, and the answer shapes the window you order.

Even where the stair carries the escape strategy, many loft rooms are still given an escape-size roof window. It gives a rescue point and also gives the room a generous opening for airing and furniture. Whether it is required or simply sensible is worth settling early, because it changes the model, not just the handle.

The size and height figures an escape window must meet

Approved Document B sets out a small set of dimensions for an escape window. They apply to the clear opening you get with the sash open, which is why two windows with the same outer frame can give quite different results.

What Approved Document B asks of an escape window in a dwelling
MeasureGuidance figureWhat it means on a roof window
Unobstructed openable areaAt least 0.33 square metresMeasured through the open sash, clear of hinges, handles and the frame
Clear widthAt least 450mmThe gap between the side frames once the sash has swung out
Clear heightAt least 450mmMeasured along the slope, from the bottom of the opening to the sash above
Height of the bottom of the openingNo more than 1100mm above the floorSet by where the window sits on the slope relative to the finished floor
Opening methodOpenable without a removable keyA lockable handle is fine if the key stays in it or the lock is internal and keyless

Two things catch people out. First, a narrow frame can pass on area yet fail on width, so the width check comes first. Second, the 450mm minimums both have to be met at once: a long, thin opening does not qualify however much area it has. Manufacturers publish which of their sizes are rated for escape in each opening type, and those figures are the ones to check against, not the overall frame size. For the wider question of choosing a width for the room, see what size roof window you need.

Why the way the sash opens decides the outcome

A standard centre pivot roof window turns on a hinge halfway up the frame. Open it and the sash swings into the middle of the opening, so the top half tips out and the bottom half tips in. That is excellent for cleaning and ventilation, but the sash itself sits across the gap, and the clear opening left for a person is a fraction of the frame. Centre pivot windows are therefore not normally sold as escape units.

Escape roof windows are usually top hung: the sash is hinged at the head and swings outwards and upwards, clearing the whole opening. Many open to a set angle and then release further so the sash can be pushed well out of the way. Some combine top hung and pivot actions in one frame, giving a pivot for everyday cleaning and a top hung release when the whole gap is needed. The guide on how roof windows open covers the opening types in full; for escape, the question to ask is simply whether the unit you are buying is rated for it in the size you want.

Handles matter too. A low-mounted handle, or a bar along the bottom of the sash, is easier to reach from the floor than a bar at the top, particularly on a steep slope where the head of the window may be well above arm's reach.

Setting the sill height so the window can be used

The 1100mm figure is a maximum, not a target. The lower the bottom of the opening, the easier it is to climb towards, but on a pitched roof the bottom edge also sets how much of the sky, rather than the garden, you see from a chair. A roof window that meets escape rules and also frames a pleasant view from a bed or a desk is perfectly achievable; it just needs the height worked out against the finished floor level, including any new floor build-up the conversion adds.

That last point is easy to miss. A loft conversion often raises the floor with new joists, insulation and boarding, so a height measured from the old ceiling joists will be wrong. We set the window from the finished floor as drawn. The companion guide on setting a roof window at the right height for the view explains the trade-off between view, headroom and sill line in more depth.

At the other extreme, a very low opening sash in an upper storey can itself be a fall risk. Approved Document K deals with guarding at low windows, and the designer will want the escape height and any guarding need to agree with each other.

Fitting an escape-size window into a trussed estate roof

Here is where the Basingstoke housing stock comes into it. The 1960s to 1980s estates in Popley, Oakridge, Winklebury and Brighton Hill, and the later ones in Chineham and Hatch Warren, are mostly roofed with factory trusses, typically at 600mm centres. The clear gap between two trusses is less than that once the timber thickness is taken off, and the frame of the window has to fit inside it with room for the lining and insulation.

An escape opening needs at least 450mm of clear width once the sash is open, and the frame around that opening is wider still. In practice that makes escape-rated sizes the ones where the choice between "fits between the trusses" and "needs designed trimming" is most finely balanced. Some models will fit a standard gap; others, often the ones that give a comfortable margin over the minimum, will not. The table in roof window widths against 600mm truss spacing sets out the common widths against that gap.

Where the escape window has to be wider than the gap, a truss cannot simply be cut and the opening left. The roof needs a trimming design from a structural engineer or the truss manufacturer, with the load taken round the opening. The guide on when a wider roof window needs designed trimming explains that route, and the short answer to whether you can cut a roof truss to fit a roof window is worth reading before anyone reaches for a saw. On a full loft conversion the trusses are usually being altered anyway under an engineered scheme, so the escape window can be written into that design from the start rather than squeezed in afterwards.

Open top hung roof window in a converted loft bedroom above a trussed estate roof
A top hung sash lifts clear of the opening, leaving the full gap free in a loft room

Where on the slope the window should go

A rescue opening is only useful if it can be reached from outside. That points the window towards the lower part of the slope, nearer the eaves, where a ladder can get to it, and away from positions high up by the ridge. It also points it at a slope with clear ground below: a rear garden or a front path is more useful than a slope that finishes over a conservatory roof, a glass lean-to or a steep drop at the side of the house.

Inside, the route to the window must stay clear. A window above a fixed bed headboard, behind built-in storage or over a stairwell looks fine on a drawing but may not be easy to reach in the dark. The furniture plan for the room belongs in the same conversation as the window position. How far up the slope a window can sensibly sit is covered in how close to the ridge a roof window can go; for escape the answer is usually "much lower than the ridge limit".

On the front slope of an estate house, the size and position of an escape window will be visible from the street. That is rarely a planning issue outside a conservation area, but it is worth deciding deliberately, and a matching pair across the room can look more settled than one large unit.

Building Control, the designer and who signs it off

A new roof window in a loft conversion is part of notifiable building work, and the escape arrangements are one of the things the Building Control body checks. On a full conversion the architect or designer normally produces a fire strategy for the whole house, and the window specification should come out of that document rather than being chosen separately. Where we fit the roof window, we make the Building Control notification for the window work and make sure the unit, its size and its sill height match what has been drawn.

For the general position on approval, see whether roof windows need Building Regulations approval. If the project is a single window added to an existing loft room rather than a new conversion, the same size and height figures are a sensible benchmark even where the rules do not strictly apply, and it costs nothing to ask the question at the design stage.

How an escape window is planned and fitted

  1. Confirm the role. Establish with the designer whether the window is the escape route, a rescue opening alongside a protected stair, or simply a large window, because that decides the rating needed.
  2. Survey the roof. Measure the truss or rafter spacing, the pitch, the covering and the ground below each slope, and note where a ladder could stand.
  3. Choose the unit. Pick a top hung or combined escape model whose published clear opening meets the figures, and check its frame against the gap between the trusses.
  4. Set the height. Fix the bottom of the opening against the finished floor level in the drawings, with any guarding agreed.
  5. Frame the opening. Work between the trusses, or to the engineer's trimming design where the frame is wider than the gap.
  6. Fit and flash. Install the frame, the flashing kit for the tile or slate, and the sash; check it opens fully and releases as the maker intends.
  7. Line and hand over. Finish the reveals, show the occupants how the escape release works, and record the unit for the Building Control file.

Living with an escape window day to day

Once fitted, the window only works if nothing gets in its way. A blackout blind should be one that can be pushed aside or raised quickly; a fixed screen or a locked secondary panel defeats the purpose. The note on whether roof windows need blinds covers the types that suit a bedroom. If the window has a key-operated lock, leave the key in it, or choose a handle that locks without a removable key.

It is also worth showing everyone who sleeps in the room how the sash releases to its full opening. Top hung escape windows often stop at a comfortable ventilation angle first, and the second movement is not obvious to someone who has never tried it. A rehearsal in daylight means nobody discovers the mechanism for the first time in smoke.

Finally, escape planning is a whole-house job. Working smoke alarms on every level, fire doors kept shut on the stair and a clear route to the window matter as much as the rooflight itself.

A roof window in the slope of a loft room
Figure 2 A roof window in the slope of a loft room

Getting the window right for your loft

If a loft room is on the drawing board, the escape question is best settled alongside the rest of the roof window choices for an estate house loft conversion, and our roof window installation page explains how the work is carried out from survey to finish. We look at the roof itself before quoting, so the unit, the truss gap and the sill height are confirmed on your house rather than assumed. The fitting is covered by our 10-year workmanship guarantee (not insurance backed). When you are ready, ask us to survey the loft and we will measure it against the figures above.