Glass you can stand on gets all the attention, but the part of a walk-on rooflight that decides whether the room below stays dry is a narrow strip nobody looks at once the job is finished: the few centimetres where the roof membrane turns up, under or into the rooflight frame. This guide is about that strip. It covers where water tries to get past a walk-on unit, how each common flat roof covering is joined to the frame, why a flush unit asks more of the detail than one on a raised kerb, and what to check once the terrace is in use.
It assumes the glass and the supporting structure are already settled. If those are still open questions, the walk-on rooflight installation hub sets out the whole job, and the pages on load and structure sit alongside this one.
Where water tries to get in
A walk-on skylight is a hole in a flat roof that people then walk across, put planters beside and hose down. Water does not arrive from one direction. It runs across the deck towards the outlets, it sits in any shallow dip, it is driven sideways by wind against the frame, and on a terrace it is pushed along by feet and brooms. The weak points are always junctions, never the middle of a sheet of membrane or the middle of the glass.
On a walk-on unit there are four junctions to think about. The first is membrane to kerb or frame, where the roof covering stops being horizontal and has to climb or tuck. The second is the frame to the glass, which the manufacturer seals in the factory and which should not be disturbed on site. The third is the corners, where two upturns meet and the membrane has to be folded, welded or reinforced without a gap. The fourth is anything the terrace adds: paving pedestals, decking bearers, drainage channels and edge trims that sit against or near the frame.
A walk-on rooflight rarely lets water in through its glass; it lets water in where the roof meets it.
How a walk-on rooflight sits in a terrace
- Anti-slip fritted top surface, so the glass is safe to walk on when wet
- Laminated glass: several layers bonded with interlayers, so it stays in place if a layer breaks
- Sealed cavity between the laminated glass and the inner pane
- Inner pane, completing the insulated unit
- Frame carrying the glass, sealed at the edges
- Kerb around the opening, bedded to the roof structure
- Waterproofing dressed up the kerb and under the frame
- Paving on pedestals, finished level with the glass
Kerb height and the finished surface
The single decision that shapes every other detail is how high the frame stands above the waterproof layer. A rooflight on a raised kerb lets the membrane turn up the side of the kerb and finish well above any water that could pond or be blown against it. The glass then sits a step above the terrace, which some owners like as a visual edge and others trip over.
A flush walk-on unit puts the top of the glass level with the finished walking surface. That looks clean and feels safe underfoot, but the membrane still needs an upturn somewhere, so the upturn is hidden below the walking surface rather than removed. On a paved terrace the paving is raised on pedestals and the real waterproof layer sits lower down, with water running beneath the slabs to the outlets. The upturn is then measured from the membrane, not from the top of the paving. The comparison is covered in more depth in flush or upstand walk-on rooflights; here the point is only that a flush look does not mean a flush waterproof detail.
The rule: the waterproof upturn is measured from the membrane, and it has to finish above the highest water level the roof could ever hold. The exception: a system tested by its maker as a flush, fully bonded detail with its own drainage channel can finish lower, but only as that maker specifies, never as a site improvisation.
How each flat roof covering meets the frame
Around Basingstoke the flat roofs that end up carrying walk-on glass are usually rear kitchen extensions, garage roofs turned into terraces, and balconies on newer townhouses. The covering on them varies with age and builder, and each one joins a rooflight frame in its own way. The survey identifies which covering is there and whether it is sound enough to work into, or whether a new covering around the opening is the better plan.
| Roof covering | How it meets the frame | What to watch |
|---|---|---|
| EPDM rubber | Dressed up the kerb and bonded, with pre-formed or site-formed corner pieces and a termination bar at the top | Corners folded tightly with no loose flap; adhesive suited to the kerb material |
| Single-ply PVC or TPO | Hot-air welded to itself around the upturn, often onto a membrane-coated metal trim | Every weld probed along its length; welds at the corners need the most care |
| Reinforced bitumen (torch-on felt) | Layers taken up the kerb with an angle fillet at the base and a capping sheet over | Heat kept clear of the rooflight frame and glass; laps overlapping in the direction water runs |
| GRP (fibreglass) | Laminated up the kerb with corner reinforcement and a topcoat | Laminate fully bonded to the kerb; trims fixed before the topcoat, not after |
| Liquid-applied membrane | Brushed or rolled up the kerb with a reinforcing fleece embedded at the base and corners | Even thickness all round; compatibility with the frame manufacturer's primer |
Mixing coverings is where trouble starts. A mix of old felt, a new rubber collar and a liquid coating at the joins relies on three materials agreeing with each other. Where the existing roof is near the end of its life, it is usually cleaner to renew the covering over the whole deck, or a clear section of it, so that one system runs continuously to the rooflight.

Falls, outlets and where the water goes next
A flat roof is never truly flat. It is laid to a fall so that water runs to an outlet, a gutter or a scupper through the parapet. Cutting in a walk-on rooflight puts a raised box, or a flush frame, in the middle of that flow. Water arriving at the upslope side of the frame has to be able to get round it, otherwise it sits against the upturn every time it rains.
Three things help. The rooflight is positioned so that it does not sit across the main line of fall, where the geometry allows. Where the frame does interrupt the flow, a shallow cricket (a small raised saddle) on the upslope side splits the water and sends it either side. And on a flush unit, a drainage channel around the frame takes water down to the membrane layer and away. None of these work if the outlets downstream are blocked with leaves, which is why outlet access matters as much as the rooflight detail itself.
A terrace adds a further layer. Paving on pedestals or decking on bearers hides the membrane, so water runs beneath the finish rather than across it. The frame detail has to be designed for that hidden layer too. How the edge of the glass meets the paving or boards is set out in where a walk-on rooflight meets decking or paving.
Insulation, the kerb and condensation
The kerb is also a thermal junction. A walk-on unit sits within a warm or inverted flat roof build-up, and the insulation has to run up to the frame without a cold gap. If the kerb is left as bare timber or a thin metal box, it becomes the coldest surface in the ceiling below, and warm moist air from the kitchen condenses on it. From inside, that damp can look very like water coming through from outside, even when the membrane is perfect.
So the waterproofing and the insulation are detailed together: insulated kerb or insulated upstand, vapour control layer lapped to the frame on the warm side, and the membrane over the top on the cold side. The daily behaviour of the glass itself is covered in do walk-on rooflights get condensation, and the thermal side of rooflights generally sits under energy efficient rooflights.
The sequence on the day
Order matters more on a walk-on unit than on almost any other rooflight, because the terrace finish goes on top and the membrane below it will not be seen again. The work follows a fixed sequence, and each stage is checked before the next covers it.
- Opening and structure. The opening is formed and trimmed as designed, with the support for the frame fixed level. The structural side is set out in the structure a walk-on rooflight sits on.
- Kerb or upstand. The kerb is built or the manufacturer's insulated upstand is fixed, true and square, at the height the detail calls for above the finished membrane.
- Vapour control and insulation. The warm-side layer is lapped onto the kerb and the roof insulation is run tight up to it.
- Membrane upturn. The roof covering is taken up the kerb, corners are formed or reinforced, and the top edge is terminated with a bar, trim or capping as that covering requires.
- Test before cover. Welds are probed, bonded laps checked by hand, and the area around the frame is flood tested or hosed where the roof allows, with someone watching the ceiling below.
- Rooflight fixed. The glazed unit is bedded and fixed to the kerb exactly as its manufacturer specifies, with its own gaskets undisturbed.
- Terrace finish. Pedestals, paving, decking or channels go in last, set so that none of them bears on the membrane upturn or blocks the drainage path.
Walk-on rooflights in older and newer flat roofs
Most of the walk-on skylights planned around Basingstoke go into extensions rather than original roofs. A flat-roofed rear extension on a 1970s Brighton Hill or Oakridge house may still carry its first felt covering, now brittle at the edges, and cutting an opening into it is a natural moment to renew the deck. A recent single-storey extension on a Chineham or Beggarwood home will usually have a newer single-ply or rubber covering, and the question becomes whether the new upturn can be welded or bonded to the existing sheet as a continuous system. Where the house or extension is recent, it is worth checking any housebuilder or roofing warranty before the roof is opened, as some carry conditions about who alters the covering.
Whether an existing deck can take a walk-on unit at all, before waterproofing is even discussed, is a separate question answered in can a walk-on rooflight go into an existing flat roof. A roof with a planted layer brings its own drainage and root barrier needs, set out in can a walk-on rooflight sit in a green roof.
Terraces, balconies and what gets put on them
Once the roof becomes somewhere to sit, the waterproofing takes wear it was never asked to take on a plain flat roof. Planters shed soil and water against the kerb. Metal chair legs scrape at a membrane upturn that was left exposed. Barbecue ash, leaf litter and pot saucers collect in the drainage channel around a flush frame. None of this defeats a well detailed junction, but it is the reason exposed upturns on a terrace are usually protected with a trim or capping, and why nothing heavy is set down against the frame.
How a walk-on rooflight is planned into a terrace used as outdoor space, including where furniture sits, is covered in a walk-on rooflight in a roof terrace or balcony.
On a terrace over a kitchen extension, the membrane around the rooflight is protecting the one room in the house with the most steam in it and the most expensive ceiling to disturb. That is why the test before cover is never skipped.
Building Control and paperwork
A walk-on rooflight in a new or altered flat roof is building work, and the thermal and structural sides of it fall under Building Regulations; the roof covering around it is part of the same job. Where the work is notifiable, Everlight deals with the notification to Building Control as part of the installation, so the waterproofing detail, the insulation and the structure are recorded together rather than left to be explained later. The wider regulation question is answered in do walk-on rooflights need Building Regulations.
The workmanship on the installation, the membrane junction included, carries a 10-year guarantee; it is not insurance backed. The manufacturer's warranty on the glazed unit sits alongside that and depends on the unit being fitted to its instructions, which is one more reason the frame and its gaskets are left exactly as supplied.
Looking after the detail once it is in
A good waterproofing detail needs very little from its owner, but it does need a few minutes a season. The checks below are all visual and none of them involve lifting paving or cutting anything.
- Clear leaves and grit from outlets, gutters and any drainage channel around a flush frame, especially after autumn.
- Look at the corners of the upturn for any lifting edge, split or loose trim.
- After heavy rain, look for water standing against the upslope side of the frame for longer than the rest of the roof.
- Keep planters, stores and heavy furniture off the frame and off exposed upturns.
- Inside, watch for damp marks at the ceiling edge of the opening and note whether they appear after rain or after cooking and showers, as that tells a roofer which side of the detail to look at.
Cleaning the glass itself, and what to use on it, is covered in how do you keep walk-on glass clean.
Planning the junction for your roof
The waterproofing around a walk-on unit is decided at the survey, not on the day. The survey identifies the covering, the fall and the outlets, looks at how the terrace will be finished and used, and sets the kerb height and the membrane detail before a quote is written. If you are still weighing a walk-on unit against other glazing for the flat roof, the flat roof rooflight options sit alongside the walk-on glass installation hub, and the main Everlight rooflight pages cover the rest of the range. When you want someone to stand on the roof and work out the detail with you, arrange a survey of the flat roof.