GuideWalk-on rooflights

Walk-on rooflight load ratings explained

How to read the spread and point load figures on a walk-on rooflight, why the support shares the rating, and how to match it to the way a roof is used.

A basement room lit from walk-on glass above
A basement room lit from walk-on glass above

A walk-on rooflight arrives with a line on its data sheet that reads something like "imposed load" or "pedestrian load", followed by a figure in kilonewtons. That short line carries more weight than the glass colour, the frame finish or the brand on the label, because it tells you what the unit has been designed and tested to hold. This guide reads that line for you: what the units mean, the difference between a load spread over the glass and a load pressed onto one small spot, why the frame and the timbers underneath share the rating, and what to ask before a roof terrace, a balcony or a flat roof over a kitchen gets glass you can stand on.

No figure on this page is a promise about any product. The numbers belong to the manufacturer of the specific unit, and the right number for your roof depends on how the space will be used. What follows is how to make sense of them.

What a load rating is really describing

A rating is a statement from the maker: this assembly, installed to our detail, will carry this much force without failing and without bending more than we allow. It is not a measure of how tough the glass feels, and it is not a claim that the unit is unbreakable. It is an engineering limit, set with a margin, for a stated kind of use.

That last part matters. A rooflight rated for occasional maintenance access and one rated for everyday foot traffic may look almost identical from above. The difference sits in the glass build-up, the frame section and the test the maker ran. Our parent page on walk-on rooflight installation around Basingstoke covers the whole job; here the focus is only on the rating and how to read it.

Two quantities appear on a proper data sheet. One is a load spread across an area, given in kilonewtons per square metre (kN/m²). The other is a load concentrated on a small area, given in kilonewtons (kN). A kilonewton is roughly the force a mass of about a hundred kilograms exerts under gravity, which is a handy way to picture the unit without pretending to more precision than a data sheet gives.

How a walk-on rooflight sits in a terrace A section through a flat roof terrace with a walk-on rooflight set level with the paving. The glass is several laminated layers with an anti-slip fritted top, over a sealed cavity and an inner pane, held in a frame on a kerb bedded to the roof deck. The waterproofing runs under the paving and is dressed up the kerb and under the frame, and daylight passes down into the room below. Terrace Room below 1234 5678

How a walk-on rooflight sits in a terrace

  1. Anti-slip fritted top surface, so the glass is safe to walk on when wet
  2. Laminated glass: several layers bonded with interlayers, so it stays in place if a layer breaks
  3. Sealed cavity between the laminated glass and the inner pane
  4. Inner pane, completing the insulated unit
  5. Frame carrying the glass, sealed at the edges
  6. Kerb around the opening, bedded to the roof structure
  7. Waterproofing dressed up the kerb and under the frame
  8. Paving on pedestals, finished level with the glass

Spread loads and point loads are different tests

People standing, walking and gathering on a roof terrace spread their weight over the whole panel. That is the uniformly distributed load, often shortened to UDL. It governs how much the glass and frame deflect across their span and whether the bearing edges hold.

A chair leg, the heel of a shoe, the foot of a planter or a ladder foot does something else entirely. It pushes a lot of force through a tiny area, and glass is far less forgiving of that than of an even load. The concentrated load figure tests exactly this: a set force applied through a small pad at the worst place on the panel, usually near the middle or near an unsupported edge.

The two load figures on a walk-on rooflight data sheet
FigureUnitWhat it stands for on a terrace
Uniformly distributed loadkN/m²People standing, walking or gathering, their weight spread across the panel
Concentrated (point) loadkNA single heavy foot, a table or chair leg, a planter foot pressing on a small spot
Snow loadkN/m²Settled snow resting on the glass, set by site and altitude rather than by use
Impact performanceTest class, not a loadA dropped object or a fall onto the glass, and how the panel behaves if a pane breaks

A unit can meet a generous spread load and still be the wrong choice if its point load figure is modest and the plan is to put a dining table on it. That is why the two figures are read together, never one alone. The furniture question has its own short answer in can furniture sit on a walk-on rooflight?

Flush walk-on rooflight set into a paved roof terrace above a kitchen extension
Walk-on glass sits level with the terrace, so its rating has to match the floor around it

Where the target figures come from

In the UK, the imposed loads a floor, balcony or accessible roof should be designed for are set out in the structural Eurocode for actions on structures, BS EN 1991-1-1, with its UK National Annex. It sorts spaces into use categories (domestic rooms, balconies, roofs used only for maintenance, roofs used as terraces) and gives each a spread load and a point load. A structural engineer designing a roof terrace works from those categories, and the rooflight in the terrace is expected to meet at least the same figures as the surface around it.

So the right question is not "is this glass strong?" but "what category is this part of the roof, and does the unit meet that category's figures?" A flat roof that only a roofer ever walks on sits in a lighter category than a terrace reached from a bedroom door. The guide on when a roof actually needs the walk-on rating works through that decision from the other end.

The rule: match the rooflight's spread and point figures to the use category of the roof around it, as the engineer or Building Control has set it. The exception is a roof that changes use later. Glass chosen for a maintenance-only roof does not become terrace-grade because someone adds a door and some decking, so the future use is decided before the unit is ordered.

Why the frame and the roof below share the rating

A manufacturer tests the glass in its frame, sitting on a support of a stated size, fixed in a stated way. The rating belongs to that whole arrangement. Change the bearing width, drop the packers, sit it on a kerb of a different section or on joists that flex more than the test rig did, and the stated figure no longer describes what is on your roof.

This is the part a homeowner cannot see once the job is finished, and it is where a load rating most easily stops meaning anything. The timbers or steel under the opening have to carry the rooflight, the people on it and the surrounding terrace build-up, and they have to stay stiff enough that the glass does not bend beyond its design. Trimming joists around a new opening is designed work, just as it is for a roof window cut between the trusses of an estate house. The full picture of that support sits in the structure a walk-on rooflight sits on.

The glass carries the people; the roof carries the glass; the rating is only true if both do their share.

Laminated layers and what happens after a break

Walk-on glass is laminated: several sheets of toughened or heat-strengthened glass bonded together with a tough interlayer. The reason is not only strength. If the top sheet is cracked by a dropped pot or a hard knock, the layers below keep carrying the load and the interlayer holds the broken pieces together, so nobody falls through and nothing drops into the room.

A serious data sheet therefore talks about post-breakage behaviour as well as the headline load. It will say which sheets are sacrificial (often the upper one, which also carries the grip finish) and which are counted on to hold the stated load. That detail is part of the rating, not an extra. How the sheets, interlayers and the sealed unit fit together is set out in the glass build-up in a walk-on rooflight, and the direct answer on depth is in how thick is walk-on rooflight glass?

Reading a data sheet before you order

A trustworthy specification gives you enough to check the unit against the roof. Work through it in this order and gaps show up quickly.

  1. Find both load figures. Look for a spread load in kN/m² and a point load in kN. A sheet that offers one without the other, or a loose phrase such as "suitable for foot traffic", has not told you enough.
  2. Check the test size. Ratings are proven on a panel of a given size. A larger panel of the same glass carries less, so confirm the figure applies to the size you want. How large can a walk-on rooflight be? covers the size side.
  3. Read the support conditions. Note the bearing width, the kerb or upstand section and the fixing method the rating assumes, then compare them with the opening on your roof.
  4. Look for post-breakage and impact information. The sheet should say how the panel behaves with a broken ply and what impact test it has passed.
  5. Confirm deflection. Glass that is safe can still feel springy underfoot. A deflection limit tells you how much movement to expect when someone walks across it.
  6. Match it to the use. Put the figures next to the category the roof has been designed for. If they fall short, choose a different unit or a smaller one, never an optimistic reading.

Snow, rain and the loads nobody stands on

Weather adds its own load. Settled snow can sit on a flat walk-on rooflight for days, and the design snow load depends on where the building is and how high above sea level, not on how the terrace is used. Around the Basingstoke area, towns on the higher ground of the North Wessex Downs, such as Kingsclere, sit higher than the Loddon valley villages, and the engineer's figure reflects that. For a walk-on unit the snow figure is almost always lighter than the pedestrian figures, yet it is still checked, because snow sits at the same time as ponding water and drifts against a parapet. The short answer is in can snow sit on a walk-on rooflight?

Standing water matters too. A flush unit on a roof with poor falls can hold a shallow pool at its edge, and that water adds weight and keeps the seals wet. Falls and drainage are a waterproofing subject more than a load one, but they are designed at the same time.

Everyday use that tests a rating hardest

Most of the time a walk-on panel is simply walked across. The loads that come closest to its limits tend to be the ones nobody thinks of as loads.

Common terrace uses and which figure they test
UseFigure it leans onWhat to decide
Dining table and chairsPoint loadWhether furniture sits on the glass or beside it; wide feet or pads spread the force
Heavy plantersPoint load and spread load togetherKeep large planters on the solid roof; a saturated pot is heavier than it looks when dry
Ladder for window cleaningPoint loadPlace ladder feet off the glass, or on a spreader board if they must stand on it
A gathering on the terraceSpread loadConfirm the terrace category covers a crowd, not just a couple of people
Children and petsImpact and gripJumping is a dynamic load; grip finish matters as much as strength

Hot tubs are the one use that sits well outside a pedestrian rating. A filled tub is a very heavy object on a small footprint, and it belongs on a structure designed for it, clear of the glass. Families weighing up the jumping and the grip side can read are walk-on rooflights safe for children and pets?

Rating words that mean less than they sound

Some wording on product pages sounds reassuring and tells you little. "Heavy duty", "load bearing" and "walkable" have no fixed meaning. "Trafficable" is a proper trade term for a surface made for foot traffic as normal use, and what does trafficable mean for a rooflight? explains it, but even that word needs the figures behind it. "Suitable for maintenance access" means someone can kneel on it carefully to clean it, which is a different thing from a terrace floor.

A flat skylight sold for a non-accessible roof is a perfectly good product for that roof. The trouble only starts when it ends up under chairs because the roof changed use. If a quotation for a walk-on rooflight gives you a brand and a size but no load figures, ask for the data sheet before you agree anything.

A walk-on glass rooflight set into a terrace
Figure 2 A walk-on glass rooflight set into a terrace

How the rating fits into the survey and the paperwork

At the survey we look at what the space will be used for, what sits under the proposed opening and how the roof is built, then choose a unit whose published figures fit that use at the size you want. Where a terrace or a new opening is part of wider building work, the engineer's design and the Building Control officer's view of the use category set the target, and the rooflight is specified to meet it. Where the rooflight work itself is notifiable, the notification is arranged as part of our job, so the load paperwork and the building record stay together.

Once the unit is chosen, the data sheet is kept with the job, alongside the 10-year workmanship guarantee (a written guarantee on the fitting, not an insurance policy). If you later sell the house, a buyer's surveyor asking what the glass is rated for gets an answer on paper rather than a shrug.

Planning a terrace over an extension or a new opening in a flat roof? Ask us to survey the roof and we will match the rating to how you mean to use it. For the wider picture of how we fit rooflights on every kind of roof, start at rooflight and skylight installation in Basingstoke, or go back to the walk-on rooflight service page.

Free roof survey

Tell us about your roof

  • Survey before any quote
  • No obligation
  • Plain-English advice

Say what you have in mind and where. We survey the roof before we quote, then tell you plainly what fits.

Prefer to talk? 01256 213206

Request my survey