Question answered · Conservation rooflights

Are conservation rooflights warm enough?

The short answer

Yes, for a heated attic room, provided the whole opening is specified and fitted with heat in mind. A new conservation rooflight carries sealed double or triple glazing and has to meet the same thermal requirement under Building Regulations as any other replacement or new rooflight. What decides how warm the room feels is the frame, the insulation around the lining and where the unit sits on the slope, more than the heritage styling.

A conservation rooflight in a clay tile cottage roof

The worry is understandable. The slim black frame looks like the Victorian cast iron originals, and anyone who has slept under one of those remembers a cold draught and drips on the pillow. Our conservation rooflight installation page covers choosing and fitting these units on the older roofs around Basingstoke; this answer deals only with warmth, and with the parts of the job that decide it.

Where the heat goes around a rooflight

Heat leaves an attic room through a rooflight in three places: through the glass, through the frame, and through the timber and plaster around the opening. The glazing gets the attention, yet the other two are where period roofs catch people out. A cut rafter roof in Old Basing or Overton is often shallow in depth, so the insulation between the rafters is thin to begin with, and the reveals formed around a new opening are easy to leave bare.

A steel frame is also a better conductor than timber or PVC. Makers deal with that using a thermal break inside the frame section, and some models add an insulated inner lining or upstand. The detail differs from one product to the next, so the data sheet for the exact model is what we check, not the brochure headline.

Heat loss paths at a conservation rooflight
PathWhat limits itWhat to ask about
GlazingSealed unit with a low emissivity coating and gas fillThe whole-unit U-value, not a centre-pane figure
FrameA thermal break between the outer and inner metalWhether the frame section is broken, and how the inner face is finished
Reveals and liningInsulation carried right up to the frame on all four sidesHow the lining is formed and what fills the gap behind it
Air leakageSeals on the opening sash and a sealed junction to the vapour control layerHow the membrane is taped to the frame inside
How a sealed rooflight unit works and fails Two close-up edge sections of a double-glazed rooflight unit. On the left a healthy unit: two panes held apart by a warm-edge spacer bar filled with desiccant, primary and secondary seals, a dry sealed cavity and a low-emissivity coating on one inner face. On the right the edge seal has broken, moist air has got in and mist sits between the panes; a small inset shows condensation on the room-side face of the glass instead, which is a ventilation issue, not a failed unit. Healthy unit Failed seal 1234 5678

How a sealed rooflight unit works and fails

  1. Outer and inner glass panes, with the outer pane facing the weather
  2. Low-emissivity coating on one inner face, reflecting heat back into the room
  3. Warm-edge spacer bar holding the panes apart, filled with desiccant to soak up trace moisture
  4. Primary seal against each pane, backed by the secondary seal around the edge
  5. Dry sealed cavity, the insulating layer between the panes
  6. Broken edge seal: moist air gets in and the desiccant becomes saturated
  7. Mist and droplets trapped between the panes; they cannot be wiped off and the sealed unit needs replacing
  8. Inset: condensation on the room-side face of the glass is a ventilation or humidity issue, not a failed unit

Reading the U-value properly

A U-value describes how readily heat passes through something; the lower the figure, the warmer the element. For a rooflight the number that counts under the regulations is the whole unit, frame and glass together, measured at the pitch it is installed. A figure for the glass alone will always look better than the complete window, so comparing a centre-pane number on one product with a whole-unit number on another tells you nothing.

Conservation models are tested and declared in the same way as standard roof windows, and the makers publish them per size and glazing option. Heat loss standards in general are set out on our energy efficient rooflights hub, so we will not repeat them here. The practical point is simple: choose the glazing option for its declared whole-unit value and check it clears the requirement before the order is placed.

The rule: a new conservation rooflight in a heated room must meet the thermal requirement, and we submit the Building Control notification that confirms it. The exception sits with listed buildings, where the conservation officer may ask to keep an original frame and the thermal standard is balanced against the protected fabric before anything is agreed.

How a slim frame affects comfort

The feature that makes a conservation rooflight acceptable to a planning officer, a low profile lying close to the tiles, has a thermal side too. A unit that sits down in the roof plane has less frame standing proud in the wind. The flip side is that the frame edge sits close to the rafters and battens, so the fit inside has to be tidy: the lining should meet the frame cleanly, with insulation packed behind it, rather than leaving a cold gap where the plaster stops short.

Why the low profile matters in planning terms is explained in our guide to flush fitting and the low profile. In the loft, the same detail is simply a question of careful carpentry around the frame.

Attic bedroom under a clay tile roof with a slim conservation rooflight and insulated lining
Insulated reveals carried up to the frame keep the edge of a conservation rooflight from feeling cold

Double or triple glazing for warmth

Whether a conservation skylight is double glazed at all is covered in are conservation rooflights double glazed? On warmth alone, the choice comes down to the room. Triple glazing earns its extra weight and depth over a study or bedroom used through the winter, on a north facing slope, or where the rooflight is large relative to the room. For a landing or a stair that you pass through, a good double glazed unit is usually the sensible specification.

A blind helps as well. A close fitting blind on the room side cuts the chill felt on winter evenings and the heat gain on summer afternoons; the options for these frames are set out in can a conservation rooflight have a blind?

What we do on site to keep the room warm

  1. Measure the roof depth. At the survey we note the rafter depth and the insulation already there, because a shallow cut rafter roof leaves less room to insulate around the reveal.
  2. Choose the glazing. We match the declared whole-unit value to the room and its use, then confirm the size suits the rafter spacing.
  3. Seal the opening. The vapour control layer is taped to the frame so warm, moist air cannot reach the cold timbers behind.
  4. Insulate the reveals. Insulation goes in on all four sides before the lining is fixed and finished.
  5. Hand over. The work is notified to Building Control and covered by a 10-year workmanship guarantee, which is ours and is not insurance backed.

None of these steps is peculiar to a period roof, yet they take more care in one, which is part of why some owners ask whether conservation rooflights are harder to fit.

Condensation on a winter morning

A modern sealed unit keeps the inner pane far warmer than single glass, so the dripping of the old cast iron skylight is not the normal experience. Water can still form on the metal edge of the frame in a humid bedroom or beside a shower room, which points to moisture in the room rather than a fault in the unit. Brief ventilation each morning, through the opening sash or a trickle vent where the model has one, keeps it in check.

The fuller treatment of the unit and the cut rafter work lives in the guide to fitting a conservation rooflight in a cut rafter roof. To have the warmth question settled for your own attic, from a cottage in Kingsclere to a villa in Odiham, arrange a survey and we will specify the glazing and the lining together. For newer estate houses, see our wider rooflight installation around Basingstoke.

Free roof survey

Tell us about your roof

  • Survey before any quote
  • No obligation
  • Plain-English advice

Say what you have in mind and where. We survey the roof before we quote, then tell you plainly what fits.

Prefer to talk? 01256 213206

Request my survey