Look down from an upstairs window at the back of a Basingstoke house and the flat roof below will be one of three things: black or grey mineral felt, a smooth, slightly glossy skin of fibreglass, or a matt sheet of synthetic rubber. Each of those coverings keeps water out in its own way, and each one meets a flat rooflight in its own way. The glass unit you choose matters less at this point than the join between that covering and the kerb the rooflight stands on, because the join is where rain is tested every time it falls.
So this guide starts from the membrane, not the product brochure. It explains how to tell which one you have, how a felt, GRP or EPDM roof is turned up and sealed around a rooflight, what changes when the covering is tired, and what we check on a survey before we write down a specification.
Three coverings, three ways of keeping water out
Felt, GRP and EPDM all do the same job, but they are made and laid in quite different ways, and that difference follows them right up the side of a skylight kerb. Felt is built up in layers of bitumen sheet bonded to each other. GRP is a resin and glass matting laminate that cures on the roof into one rigid shell. EPDM is a single sheet of rubber, glued to the deck, with its joins made by tape and primer rather than heat.
What that means for a rooflight is simple to state. With felt the upstand gets its own layers, lapped into the field of the roof. With GRP the laminate carries on up the kerb as one continuous piece, finished with trims. With EPDM the sheet is either folded up the kerb or joined to a separate upstand strip, and the corners are formed with preformed pieces or careful folds. None of these is better in every case; the right detail is the one that suits the roof already there.
Flat rooflight on an insulated upstand
- Double glazed rooflight, set to a slight fall so rain runs off the glass
- Upstand (kerb): a timber kerb with insulation on its outer face
- Membrane dressed up the upstand and over the top, sealed under the rooflight frame
- Waterproof membrane covering the roof, falling towards the gutter outlet
- Insulation laid over the deck, keeping the structure warm
- Roof deck on tapered firrings, which create the fall
- Joists, trimmed around the opening with trimmer joists
- Plasterboard reveal lining the opening, meeting the ceiling below
How to tell which covering your roof has
You can usually tell from a first floor window or from the top of a ladder, without walking on the roof. The table sets out the signs and how each covering behaves once a rooflight goes in.
| Covering | What you see | How it meets the kerb | Weather it needs |
|---|---|---|---|
| Mineral felt (built up or torch on) | Grainy surface with stone chippings or mineral finish, visible laps where the sheets overlap | Layers dressed up the upstand and lapped onto the roof, with a capping sheet over the top | A dry deck; torch on work also needs a hot works plan near timber |
| GRP fibreglass | Smooth, hard coloured topcoat with plastic or aluminium trims at the edges | Matting and resin laminated up the kerb as one piece, then a topcoat | Dry and not too cold, so the resin cures properly |
| EPDM rubber | Matt black sheet, often one piece, with a slightly soft feel and flat trims | Sheet or upstand strip bonded up the kerb, corners formed and seams taped | Dry surfaces for the adhesive and primer |
| Older mixed roofs | Felt with later coatings, or a newer membrane laid over old felt | Decided at survey, once the layers under the surface are known | Depends on the covering chosen |
Garages and 1970s and 1980s extensions on the estates around the town are often felt. Newer extensions tend towards GRP or EPDM. That is a pattern, not a rule, which is why the survey looks at the edge trims and, where needed, a lap or a trim from close up.
Felt roofs: the traditional lapped detail
A felt roof is waterproof because of its layers. The field of the roof has an underlayer and a cap sheet, sometimes with a middle layer, and each one is bonded to the one below. Around a rooflight those layers are carried up the kerb: an angle fillet softens the corner at the base so the felt is not folded sharply, the upstand layers are bonded to the timber, and the cap sheet is lapped over them and down onto the roof so water always runs over a joint rather than into it.
Torch on felt is laid with a gas flame, which suits the bitumen but asks for care near timber kerbs, fascia boards and anything that can char. A good installer plans the heat work, keeps the flame away from exposed timber and stays on site after the torch goes out to watch for smouldering. Cold applied and self adhesive felt systems avoid the flame altogether and are often a sensible choice around a new kerb.
A felt roof does not rule out a flat skylight. If you only want the direct answer, can a flat rooflight go on a felt roof? gives it in a few paragraphs. The judgement lies in the age of the felt: new layers bond well to sound felt, and poorly to felt that has dried out and cracked.
GRP roofs: laminating the kerb into one shell
A fibreglass roof is one continuous laminate. That is its strength around a rooflight, because the kerb can be made part of the same shell. The deck and the timber upstand are prepared, a corner trim or fillet goes in at the base, and glass matting is wetted out with resin across the roof and up each face of the kerb, so there is no seam where the flat meets the vertical. Once it has cured, a coloured topcoat seals the surface.
The difficulty comes when the rooflight is added to an existing GRP roof. The old laminate has to be cut cleanly around the new opening, the surface keyed and cleaned, and new matting overlapped onto it. Resin bonds best to fresh, properly prepared laminate; a rushed join between old and new is the weak point. Cold, damp days slow the cure, so GRP work is timed around the weather rather than squeezed into it.
GRP is also rigid. If the deck under it moves, the laminate can craze at the corners. That is one reason we look closely at the deck boards and at how the kerb is fixed before choosing to laminate into the old surface.

EPDM roofs: bonding rubber to an upstand
An EPDM roof is usually a single sheet, cut to size and glued to the deck. Around a rooflight there are two common approaches. On a new roof, the sheet can be folded up the kerb and bonded, with the corners formed by folds that keep the membrane in one piece. On an existing roof, the sheet is cut back and a separate strip is bonded up the kerb, joined to the field of the roof with seam tape and primer, and finished with preformed corners.
The rubber itself is stretchy and handles small movement well, which is useful at a kerb. What decides the outcome is the preparation: clean, dry surfaces, the right primer for the membrane, pressure rolled seams and a trim or termination at the top of the upstand so the edge of the sheet is covered by the rooflight frame. EPDM does not like solvents or bitumen products left on it, so the choice of sealants matters too.
The rule at every kerb, whatever the covering
Whichever membrane is on the roof, the same principle governs the join. We explain the choice between a kerb built on site and one made in a factory in timber upstand or factory kerb for a flat rooflight, and the short version of whether you need a kerb at all is in does a flat rooflight need a kerb?
The rule: the waterproof covering is carried up the full height of the kerb and finishes under the rooflight frame, so the frame overlaps the membrane and rain runs over the top of the joint. The exception is a factory kerb supplied with its own collar or flange, where the maker's detail sets how the covering is joined and the installer follows it.
Getting that order right means water arriving at the kerb meets the frame, then the membrane, then the roof, and never finds an open edge.
Fitting a rooflight into an existing covered roof
Most flat rooflights around Basingstoke go into roofs that are already covered, over a kitchen extension, a garage or a link between the two. The sequence is broadly the same for all three coverings, with the membrane work in the middle changing to suit felt, GRP or EPDM. Adding a flat rooflight to an existing flat roof covers the structural side; this is the covering side.
- Mark and check. The opening is set out between joists, clear of outlets and edge trims, and checked from inside against the room below.
- Cut back the covering. The membrane is cut back around the opening, leaving enough sound material for the new layers or laminate to lap onto.
- Form the opening. The deck is cut, trimmers fitted where the design calls for them, and the kerb fixed to the structure.
- Weather the kerb. Felt layers, GRP laminate or EPDM upstand strips are taken up the kerb and joined to the existing roof in the way that membrane demands.
- Fit the rooflight. The unit is bedded and fixed to the kerb so its frame covers the top of the membrane.
- Finish inside. Insulation, lining and plaster go in around the opening, and the ceiling is made good.
When the covering is near the end of its life
Sometimes the honest answer at the survey is that the covering will not take a new join well. Felt that has blistered, lost its chippings or cracked along the laps, GRP that has crazed across the surface, or EPDM with lifting edges all make a poor base for fresh work. Tying a new skylight into a tired roof puts the newest part of the roof next to the oldest.
In that case the sensible option is often to recover the roof and fit the rooflight at the same time, so the kerb is weathered into a new membrane from the start. It is also a good moment to look at insulation, because a warm deck roof built over the joists changes the height of the kerb needed. How long each part lasts is covered in how long does a flat rooflight last?
The glass gets the attention, but it is the join between membrane and kerb that keeps the room dry.
Water, falls and the uphill side of the kerb
A kerb is a small dam on a flat roof. Water running down the fall reaches the uphill side and has to find its way round, so the membrane there takes the most work. Keeping the rooflight clear of outlets and the lowest point of the roof, and making sure the fall carries water past the kerb rather than into a pond against it, protects the covering whichever type it is. Our guide to drainage falls that move water past a flat rooflight covers this in full.
Water standing on the glass itself is a separate matter from water standing on the roof. It comes down to the angle of the glazing rather than the covering, which is why why a flat rooflight is never actually flat is worth reading alongside this page, and why does water sit on a flat rooflight? answers the everyday question.
What we look at before we write the specification
The survey settles which of these details your roof gets. From the ground, a ladder and inside the room, we identify the covering and its condition, look at the edge trims and outlets, check the fall, and find the joist direction and spacing below. From that we can say whether the rooflight is weathered into the existing membrane or whether recovering the roof first is the better route, and write it down before any price is agreed.
Around Basingstoke the flat roofs over estate garages and rear extensions span several decades of building, so a felt garage roof and a newer GRP or EPDM kitchen roof can sit side by side on one property. Each is treated as its own roof.
Notification to Building Control, where the work needs it, is part of our job rather than yours, and the workmanship on the kerb and membrane is covered by our 10-year guarantee, which is not insurance backed.
Choosing the next step
If your flat roof is sound, almost any of the three coverings will take a well made rooflight kerb; the work is in matching the detail to the membrane. If it is tired, fitting the rooflight alongside a new covering is usually the better use of the day on the roof. The flat roof rooflight installation service sets out the whole job from structure to finish, and the wider picture of skylight installation in Basingstoke starts on our home page.
When you would like someone to look at the covering itself and tell you which detail suits it, arrange a survey of your flat roof and you will have the answer in writing, along with the specification for your flat rooflight.