Look at a flat rooflight from the garden and you see the glass. Look at it from a ladder and you see what it is standing on: a low box, a few inches proud of the roof, with the covering dressed up its sides. That box is the upstand, and it can be made in one of two ways. A carpenter can build it from timber on the roof, or the rooflight maker can supply it ready made as a factory kerb. Both carry the same skylight. They behave differently when the covering is dressed to them, when the roof is cold, and when the unit on top is eventually changed.
This guide sets the two side by side for the kinds of flat roof found on houses around Basingstoke: the single storey kitchen extension, the flat roofed garage beside a 1970s semi, the link between house and garage on a later estate. It explains what each kerb is good at, where each one struggles, and how the choice is settled on a real roof rather than in a brochure. It sits under our wider page on flat roof rooflight installation, which covers the whole job.
What the upstand is there to do
An upstand has three jobs, and it is worth naming them before comparing the two types, because every difference between timber and factory kerbs comes back to one of them. First, it lifts the glazed unit clear of the roof surface, so rain running across the deck passes around the frame instead of pooling against its seal. Second, it gives the roof covering a vertical face to turn up against and finish on, which is how the joint between roof and rooflight is made watertight. Third, it forms the top of the shaft that daylight travels down into the room, so it is part of the thermal envelope and part of what you see from below.
A kerb that does all three well is invisible once the job is finished. A kerb that does one of them badly tends to show it, as a damp shadow on the reveal, a membrane that has pulled away at a corner, or a frame that never quite sits level. For the plain yes or no on whether a kerb is needed at all, see does a flat rooflight need a kerb? The rest of this page assumes it does, and asks which kind.
Flat rooflight on an insulated upstand
- Double glazed rooflight, set to a slight fall so rain runs off the glass
- Upstand (kerb): a timber kerb with insulation on its outer face
- Membrane dressed up the upstand and over the top, sealed under the rooflight frame
- Waterproof membrane covering the roof, falling towards the gutter outlet
- Insulation laid over the deck, keeping the structure warm
- Roof deck on tapered firrings, which create the fall
- Joists, trimmed around the opening with trimmer joists
- Plasterboard reveal lining the opening, meeting the ceiling below
The timber upstand: built to the opening on site
A timber upstand is a rectangular frame of treated softwood fixed around the opening in the deck, usually onto the trimmed joists or onto the deck and into the joists below. The carpenter cuts it to the size of the opening and the rooflight, sets its height, and can plane or pack the top so that it slopes gently in one direction. Its outer faces are then boarded so the roof covering has a continuous surface to run up, and its inner faces are lined, insulated and plastered to join the ceiling below.
The strength of timber is that it answers to the roof, not to a catalogue. An opening can be any width the joists allow. The height can be raised on a roof where the deck has been built up with new insulation, or where a thick layer of stone ballast or a green roof needs clearing. The top can be set to a fall that suits the direction water already takes across that particular roof. And because it is ordinary carpentry, it can be matched to an existing opening when an old dome or flat unit is being changed and the kerb underneath is sound enough to keep.
Its weakness is the other side of the same coin. Everything about a timber upstand depends on who builds it: the grade and treatment of the timber, how square the corners are, how the insulation is fitted inside it, and how the covering is dressed over its top edge. Timber on its own is a poor insulator compared with the foam cores used in factory kerbs, so a timber upstand has to be lined with insulation board on the inside, the outside or both, or it becomes the coldest part of the ceiling.
The rule: a timber upstand is only as good as its insulation and its top edge. The exception is a kerb that is being kept under a replacement unit, where the upstand already exists and the question becomes whether it is dry, square and warm enough to carry the new frame, which the survey checks by opening it up at the edges.
The factory kerb: made for the unit that sits on it
A factory kerb is a prefabricated upstand supplied by the rooflight maker, or designed alongside a particular range. Depending on the maker it may be moulded from GRP or uPVC, or built as an insulated composite, often with a rigid foam core. It arrives at the size of the rooflight, frequently with its top already angled so the glass sheds water, and with a flange or skirt at its base that lies on the deck and is bonded into the covering.
Because the kerb and the frame are made to go together, the fit on top is exact. The frame locates on the kerb as the maker intended, the seal between them is the one the maker tested, and the height and angle are fixed at the factory rather than by a spirit level on a windy roof. On a new flat roof, where the opening can be formed to suit, that makes the finished job consistent and quick to complete, and it keeps the thermal performance of the upstand close to what the maker states for it.
The limits are also built in. A factory kerb comes in the sizes the range offers, so the opening has to follow the kerb, not the other way round. Its base flange has to be compatible with the roof covering it is bonded to, which is not a given across every membrane. And on an existing roof, the kerb still needs something solid to sit on: trimmed joists or a timber sole frame, which means some site carpentry happens anyway, only lower down.

Timber upstand and factory kerb compared
Neither type is the better one in every case. The table puts them next to each other on the points that actually decide the choice on a house roof.
| Point | Timber upstand | Factory kerb |
|---|---|---|
| Size of opening | Any size the joists and trimming allow, including bespoke units | The sizes offered in that rooflight range |
| Height and angle | Set by the carpenter to suit the roof build-up and its fall | Fixed at the factory, often with the angle built into the top |
| Insulation | Added on site with insulation board, inside, outside or both | Usually an insulated core as part of the kerb |
| Joint with the covering | Covering dressed up boarded faces and over the top edge | Base flange bonded into the covering; flange and membrane must be compatible |
| Fit of the frame | Depends on the kerb being built square and true | Frame and kerb made to locate together |
| On an existing roof | Can match or reuse an existing opening | Opening formed or adjusted to the kerb size, on a solid base |
| Later unit change | A new frame of the same footprint can go back on the same kerb | Best matched by a unit from the same range |
Read down the columns and a pattern appears. Timber wins where the roof is irregular or the size is unusual. A factory kerb wins where the opening is new and the rooflight is chosen from a standard range.
How the roof covering meets each kind of kerb
The joint between the covering and the upstand is where a flat rooflight either stays dry or does not, so it deserves a close look. On a timber upstand, the covering simply keeps going: the GRP laminate, the felt layers or the EPDM sheet are turned up the boarded sides, taken over the top edge and finished under the frame of the rooflight, which then clamps or covers the termination. Done properly, there is no separate joint at all, just the same waterproof skin changing direction.
On a factory kerb, the covering usually stops at the flange. The flange is bonded down and the covering is dressed over it, or a membrane collar supplied with the kerb is lapped into the roof. That works well where the maker has confirmed the collar suits the covering, and it is worth checking before anything is ordered: a flange intended for a liquid applied system is not automatically suited to torch-on felt, and EPDM has its own adhesives and primers. The full detail by covering is in fitting a flat rooflight to GRP, felt and EPDM roofs, and the short answer for felt sits in can a flat rooflight go on a felt roof?
Height, angle and where the water goes
Two measurements matter on any upstand: how high its top sits above the finished roof, and whether that top is level or tilted. The height keeps the frame seal above any water that sits on the deck after heavy rain or snow melt, and it has to be taken from the finished surface, not the bare boards, because new insulation and a new covering add depth. The rooflight maker states the minimum it wants in the fitting instructions for the unit.
The angle is about the glass rather than the roof. A glazed unit laid dead level holds a film of water and collects dirt where it dries. A small tilt, built into a factory kerb or cut into a timber one, lets rain run off the glass towards the roof fall. Why that tilt matters, and how it is set, is explained in why a flat rooflight is never actually flat, and the figure makers quote is covered in what is the minimum pitch for a flat rooflight?
The kerb is measured from the roof you will have when the job is finished, not the boards you can see on the day.
Keeping the kerb as warm as the roof around it
Any upstand pokes up through the insulation layer of the roof, which makes it a place where heat can find a short route out. On a warm deck roof the insulation sits above the boards, and the kerb has to be insulated up to meet it with no gap at the joint. On an older cold deck roof, with insulation between the joists below, the inner faces of the shaft need their own lining so the plaster inside the reveal does not end up colder than the ceiling around it.
A factory kerb brings its own insulated core, which covers most of the height. A timber upstand relies on board fixed to it on site. Either way, the weak spot is usually the joint between the kerb and the roof insulation, not the kerb itself. That hidden line is the subject of insulation at the kerb and the cold line you cannot see, which is worth reading before choosing a kerb for a kitchen extension where the reveal will be in plain view.
When the roof you already have makes the decision
On a new extension, the builder forms the opening, and either kerb can go on. On an existing flat roof the choice is often narrower. An older garage or rear extension on a 1960s or 1970s estate may already carry a timber upstand under a tired plastic dome. If that upstand is dry, sound and the right size for a modern unit of the same footprint, keeping it can be the tidiest route, with fresh insulation and the covering dressed back up to it. If it is soft, out of square or too low for the new roof build-up, it comes out, and the new kerb is chosen afresh.
Joists matter too. A factory kerb in a standard size may not line up with the joist spacing, which can mean trimming a joist that a bespoke timber upstand would have avoided. Where the roof is being opened up for the first time, the sequence and the checks are set out in adding a flat rooflight to an existing flat roof, and the structural side is answered in the parent page on flat rooflights for extensions and garages.
How the kerb is chosen at the survey
No quote is written until the roof has been looked at, and the kerb is one of the decisions the visit settles. The order is the same whichever way it goes.
- The covering. Identify the roof finish and its condition, since that decides how any kerb will be sealed in and whether a factory flange suits it.
- The deck and build-up. Check whether the insulation is above or below the boards, and how deep the finished roof will be, to set the kerb height.
- The joists. Find the joist direction and spacing below the chosen position, so the opening can be sized between them or trimmed by design.
- Any existing upstand. Open up an existing kerb at its edges to see if the timber is dry and true enough to keep.
- The unit. Match the rooflight you want to a kerb: a factory kerb from its range, or a timber upstand built to its footprint.
- The written specification. Set down which kerb, its height, its angle and how it is insulated, so the choice is visible before any work is booked.
That way you are not choosing between two words on a quote. You are choosing between two ways of building something you can picture, with the reason written next to it.
Building Control and the kerb
A new opening in a roof, with a new rooflight in it, is building work that Building Control takes an interest in, chiefly for the structure around the opening and for the heat lost through the unit and its surround. The kerb is part of that surround, so its insulation matters for the paperwork as well as for comfort. Where the job is notifiable, Everlight deals with the notification, and the kerb specification forms part of what is recorded. For the direct answer on approval, read do flat rooflights need Building Regulations approval?
Picking the kerb that suits your roof
If the opening is new, the rooflight is from a standard range and the covering suits its flange, a factory kerb tends to be the neat, predictable choice. If the size is bespoke, the roof has been built up, the joists fight a standard size or a sound old upstand is already there, timber is usually the better fit. Either kerb can make a good flat roof; what matters is that the kerb was chosen for that roof.
The same thinking runs through all of our rooflight and skylight work around Basingstoke: find out how the roof was built, then specify to it. Every installation carries a 10-year workmanship guarantee, not insurance backed, and a written quote follows the survey. When you want to know which kerb your extension or garage needs, ask us to survey the roof and we will show you on the roof itself.