Put your hand flat against the inside face of a rooflight shaft on a cold January morning. If the plaster feels noticeably colder in a band just below the frame than it does a hand's width lower, you have found the cold line. It is invisible from the room and it does not show up in the glazing specification, but it decides whether the shaft stays dry and clean or grows a grey stripe of mould along the top of the reveal. This guide is about that band: where the insulation of a flat roof stops, where the rooflight frame begins, and what has to happen at the kerb so the two meet without a gap.
The glass gets the attention when people compare units. The kerb is where the heat goes.
Why the kerb is the weak point, not the glass
A modern double or triple glazed flat rooflight has a sealed unit designed to hold heat, and a frame built to sit on a raised base. That base, the kerb or upstand, lifts the glass above the roof so rain runs off and the waterproofing can be dressed up its sides. The trouble is that the kerb pokes up through the insulated layer of the roof and stands in the open air on three sides: outside face, top edge and, inside the room, the shaft face. Anything that crosses from warm to cold like that is a candidate for a thermal bridge, a route by which heat slips round the insulation instead of through it.
On a solid timber upstand, the timber itself carries heat far better than the insulation beside it. Warm air in the room meets the inside face of the kerb, the kerb conducts some of that warmth out to the cold outside face, and the inner surface ends up cooler than the ceiling around it. The glazing may be excellent, yet the frame sits on a cold collar. The purpose of kerb insulation is to wrap or fill that collar so its inside face stays close to room temperature.
Flat rooflight on an insulated upstand
- Double glazed rooflight, set to a slight fall so rain runs off the glass
- Upstand (kerb): a timber kerb with insulation on its outer face
- Membrane dressed up the upstand and over the top, sealed under the rooflight frame
- Waterproof membrane covering the roof, falling towards the gutter outlet
- Insulation laid over the deck, keeping the structure warm
- Roof deck on tapered firrings, which create the fall
- Joists, trimmed around the opening with trimmer joists
- Plasterboard reveal lining the opening, meeting the ceiling below
Warm deck and cold deck: which roof you are standing under
Where the insulation already sits in the flat roof decides where the kerb insulation has to go. There are two common arrangements around Basingstoke, and a third that turns up on older garages and back additions.
| Roof build-up | Where the insulation is | What the kerb has to do |
|---|---|---|
| Warm deck | Rigid boards laid on top of the timber deck, under the waterproofing | Rise through the board layer with insulation lapped against its outer face so the roof insulation and the kerb insulation touch |
| Cold deck | Between the joists, below the deck, with a ventilated void above | Carry insulation down its inner lining to meet the joist-level insulation, while the roof void stays ventilated around the opening |
| Uninsulated deck | None, common on older garages and link roofs | Match the room below: if the space is heated, the roof around the rooflight usually needs upgrading at the same time |
| Inverted roof | Boards laid above the waterproofing, often under ballast | Stand tall enough to clear the boards and ballast, with its own insulation running up past them |
Knowing which one you have is a question of looking. From inside, a cold deck usually shows vents at the fascia or soffit and a deep joist zone. From outside, a warm deck roof often sits noticeably higher above the wall head than an older roof on the same street. The survey settles it by opening the ceiling at the proposed position or by lifting a section of the roof edge, and the flat roof rooflight installation service page describes how that survey is run.
The cold line, traced from outside to in
Think of the insulation in a roof as a blanket. The cold line is any place where the blanket has a gap. At a rooflight there are four such places to check, in order from outside to in.
- The outer face of the kerb. On a warm deck, the roof boards stop at the kerb. If they are cut short, or the cut is ragged, there is a strip of timber or deck exposed to cold with nothing against it.
- The top of the kerb, under the frame. The rooflight frame bears on the top of the kerb. If the frame has its own thermal break, the joint between frame and kerb needs to be continuous and sealed so no cold air runs under it.
- The inner lining of the shaft. Between the kerb and the ceiling there is a short tunnel of lining. Plasterboard alone on bare timber leaves this surface as cold as the timber behind it.
- The junction with the ceiling. Where the shaft lining meets the room ceiling, the roof insulation and the shaft insulation should overlap, not stop short of each other with a joist in between.
Miss any one of the four and the cold line reappears there. That is why kerb insulation is best thought of as one continuous wrap, not a single product fitted at one point.

Factory insulated kerbs and site-built upstands
Many flat rooflights are now offered with a factory kerb: a hollow or foam-filled upstand made to suit the frame, with insulation built in and a lip for the waterproofing to dress over. A site-built timber upstand is the traditional alternative and is still the right call where the opening is an unusual size or the kerb has to be taller than the factory range. The comparison between the two is covered in full in timber upstand or factory kerb for a flat rooflight. For insulation the point is narrower.
A factory kerb brings its insulation with it, tested with the frame, so the inner face should already be warm. It still has to be bedded onto an insulated deck, and the roof boards still have to meet it cleanly. A timber upstand arrives as bare timber, so the insulation has to be added: rigid board against the outside face before the waterproofing goes on, and an insulated lining on the inside face before the plasterboard. Neither choice gets you out of the junctions described above.
The rule: insulate the upstand on the face that sits within the roof's insulated zone and carry it up to the underside of the frame. The exception: on an inverted roof the waterproofing is below the boards, so the kerb insulation sits outside the membrane and has to be the type made to stay wet.
Condensation: what the cold line actually does
Warm indoor air carries moisture. When it touches a surface cooler than its dew point, some of that moisture comes out as water. On a rooflight, the coldest surfaces are the glass edge, the frame and, if nothing has been done about it, the top of the shaft. Kitchens and bathrooms, which are exactly the rooms that get flat rooflights on the backs of estate houses, produce the most moisture.
A small amount of misting on the glass edge on the coldest, dampest mornings is normal physics and clears as the room warms. Water forming on the shaft lining is different. It soaks into paint and plaster, feeds mould, and over successive winters stains the reveal in a line that follows the timber behind it. That tidy horizontal stripe, sitting just below the frame, is the cold line made visible.
If the stain follows the shape of the kerb, the problem is the kerb, not the glass.
The answers to that are ventilation in the room, which the rooflight can help with if it opens, and a warm shaft, which only insulation delivers. Triple glazing will not rescue a cold kerb; the page on whether a flat rooflight can be triple glazed explains where extra panes do and do not change the picture.
Vapour control around the opening
Insulation keeps the surface warm. A vapour control layer keeps moist room air out of the roof build-up where it could condense on colder timber unseen. In a warm deck roof it sits on top of the deck, under the insulation boards; in a cold deck roof it sits on the warm side of the joist insulation, just above the ceiling.
A rooflight opening cuts a hole through that layer. The layer then has to be turned up the kerb, or taped to the shaft lining, so that there is no open edge for air to slip past. On an existing roof this is the part most easily lost, because the original layer is hidden and has to be found, cut back cleanly and lapped. It is quiet, unglamorous work, and it is a large part of why fitting into a finished roof takes longer than fitting into a new one. Adding a flat rooflight to an existing flat roof walks through the sequence on a roof that is already built.
Lining the shaft so the reveal stays warm
The shaft is the short tunnel between the ceiling and the rooflight. On a thin warm deck roof it may be barely deeper than the kerb; on a cold deck with deep joists it can be a noticeable box. Either way, its inside face is the one you see and the one that shows condensation.
The usual approach is insulated plasterboard, a board with a layer of rigid insulation bonded to its back, fixed to the kerb and trimmers and taped at the joints. It adds warmth where bare plasterboard adds none. The shape of the shaft matters too: a splayed reveal, angled wider at the ceiling, lets more light spread into the room and changes the geometry of the lining, so the insulation has to follow the splay without leaving a wedge of bare timber at the top. The trade-off is set out in splayed or square reveals under a flat rooflight.
Corners are where lining goes wrong. Each internal corner of the shaft is a meeting of two boards, and each outer corner is a meeting of the shaft and the ceiling. Boards cut short at either, or fixed with a gap filled only with plaster, bring the cold line back in miniature.
How high the kerb stands, and why it affects the insulation
Kerb height is usually discussed in terms of water: the upstand has to lift the frame far enough above the finished roof for the waterproofing to be dressed up and for standing water to stay clear of the frame seal. The answer on whether a flat rooflight needs a kerb covers that side of it.
Height matters for warmth as well. On a warm deck roof the kerb has to rise past the full depth of the insulation boards and then clear the finished surface. When a roof is re-covered with thicker boards to bring it up to modern standards, an old kerb that was tall enough can end up barely peeping above the new build-up. That leaves too little upstand for the waterproofing and puts the frame junction right at the cold edge of the insulation. On a re-roof, the kerb is often raised or replaced for this reason alone.
On a flat roof over a Basingstoke estate kitchen or garage, the depth of the existing insulation is rarely known until the deck is opened. Measuring it at survey is what sets the kerb height, not the rooflight catalogue.
Building Regulations and the kerb
Fitting a rooflight into a roof is work to a thermal element, and the rules for heat loss through roofs and windows apply. The answer on flat rooflights and Building Regulations sets out when the work is notifiable and what an inspector looks at. Two points bear directly on the kerb.
First, the rooflight itself has to meet the performance required for new windows and rooflights, and that figure is for the whole unit including its frame, not just the centre of the glass. A factory kerb supplied and tested with the unit helps show that. Second, the work around the opening must not leave the roof performing worse than before. A cold kerb bolted into a well insulated roof undoes part of that roof's work. For notifiable jobs Everlight looks after the Building Control notification, and the insulation detail at the kerb is part of what that paperwork describes.
The wider question of glazing choice, coatings and whole-unit figures belongs to energy efficient rooflights; this guide stays at the junction.
What the survey checks at the kerb
Most of what decides kerb insulation cannot be seen from the room below, so the survey looks for it deliberately, in roughly this order.
- Roof build-up. Warm, cold, inverted or uninsulated, found by opening a small section or by looking at the roof edge and soffit.
- Insulation depth. Measured, because it sets the minimum height of the kerb.
- Joist direction and spacing. Which way the opening can run without trimming, and where the shaft lining will fix.
- Vapour control layer. Whether there is one, where it is, and how it will be lapped to the kerb.
- The room below. Kitchen, bathroom or living space, since that sets how much moisture the shaft will meet.
- Kerb choice. Factory kerb or insulated timber upstand, sized to the build-up that was found.
That list is why the quote comes after the survey. Two rooflights of the same size on two neighbouring extensions can need quite different kerb work, simply because one roof was re-covered with a warm deck and the other was not.
Keeping the cold line closed after fitting
Once the kerb is wrapped and lined, the job of keeping it warm is mostly done. What remains is the room: run the extractor when cooking or showering, open the rooflight or a window for a short spell after, and keep heavy blinds from trapping damp air tight against the glass for hours at a time. If a stripe of condensation does appear on the shaft in a well used room, it is worth noting where it sits. On the glass edge only, it is usually room humidity. Along the lining in a neat band, it points back to the junctions in this guide.
Every rooflight Everlight installs carries a 10-year workmanship guarantee, which is not insurance backed, and the kerb detail is part of the workmanship it covers. If you are weighing up a new rooflight or skylight for a flat roof in Basingstoke, or replacing an older one sitting on a bare timber upstand, the first step is a look at the roof itself. When you are ready, arrange a survey of your flat roof and the kerb gets measured along with everything else. More on the full service is on the flat roof rooflight page.