GuideFlat roof rooflights

Adding a flat rooflight to an existing flat roof

How a flat rooflight is added to a flat roof that is already built: reading the covering, finding the joists, joining the kerb to old membrane.

A flat rooflight over a single-storey kitchen extension
A flat rooflight over a single-storey kitchen extension

An extension roof that has been dry for years is a finished thing. Its deck is boarded, its covering is bonded down, its falls have been sending rain to the same gutter since the day it went on. Putting a flat rooflight into it means opening that finished surface, fitting a kerb, and closing the covering back around the kerb so tightly that the roof carries on behaving as one sheet. None of that is exotic, but it has a different order of questions from a rooflight drawn into a roof that is still being built.

This guide follows those questions in the order a surveyor asks them on an existing roof: what the covering is and how much life it has left, which way the joists run, where the insulation sits, how the new kerb joins the old membrane, and what happens to the ceiling underneath. The flat roof rooflight installation service page covers the whole job; this page is only about retrofitting into a roof that is already there.

New roof or existing roof: why the order changes

When a flat roof is being built, the rooflight position is set on the drawing. The joists are laid out around it, the trimmers go in with everything else, the insulation board is cut to the kerb and the covering is laid in one go over the top. Nothing is disturbed because nothing was there yet.

On an existing roof every one of those steps runs backwards. The covering is cut first, the deck is opened, the joists are found where they actually are rather than where a drawing says, and the new work is then built back up to meet the old. The skill is in the joins. A rooflight on a new roof is one layer among several; on an old roof it is the only new thing in a surface that has already settled, weathered and been walked on.

On an existing flat roof, the rooflight is only as sound as the join between the new kerb and the old covering.

Flat rooflight on an insulated upstand A section through a flat roof. Joists carry firrings, a deck, insulation and a waterproof membrane that falls towards a gutter at the edge. Around the opening an insulated timber upstand rises above the roof, the membrane is dressed up it and sealed under the rooflight frame, and the double glazed rooflight sits on top with a slight fall so rain runs off the glass. Inside, plasterboard lines the reveal of the opening down to the ceiling of the room below. OutsideRoom below12345678

Flat rooflight on an insulated upstand

  1. Double glazed rooflight, set to a slight fall so rain runs off the glass
  2. Upstand (kerb): a timber kerb with insulation on its outer face
  3. Membrane dressed up the upstand and over the top, sealed under the rooflight frame
  4. Waterproof membrane covering the roof, falling towards the gutter outlet
  5. Insulation laid over the deck, keeping the structure warm
  6. Roof deck on tapered firrings, which create the fall
  7. Joists, trimmed around the opening with trimmer joists
  8. Plasterboard reveal lining the opening, meeting the ceiling below

Reading the roof before anything is cut

The first visit is mostly looking. From outside, the surveyor checks the covering for blistering, splits, crazing, ponding and tired edge trims, and notes where the outlets and gutters are. From inside, the ceiling is checked for staining, and where there is a hatch or a light fitting the void is looked into to see the joist direction and depth. The aim is to know the roof well enough to say whether it will take a kerb as it stands.

What the survey looks at on an existing flat roof
CheckWhat it tells usWhy it matters for a rooflight
Covering typeFelt, GRP or EPDM, and whether it is bonded or loose laidEach covering is dressed up a kerb in its own way
Covering conditionHow much service life the membrane has leftA tired covering may be better renewed with the rooflight than joined to
Joist direction and spacingWhich way the timbers span and how far apart they sitSets the widths that fit between joists without trimming
Deck and build-upBoard type and whether the roof is a warm or cold deckDecides how the kerb is insulated and ventilated
Falls and outletsWhere rain runs and where it leaves the roofThe kerb must not sit across a line of water
Room belowCeiling finish, lights, beams and furniture positionsDecides where the light lands and how the reveal is finished

None of these checks involves opening the roof. They are enough to say whether the idea is straightforward, whether it needs a trimmed opening, or whether the covering itself is the real question.

The covering decides more than the glass

Homeowners usually start by choosing the unit. On an existing roof the membrane matters more, because the new kerb has to be welded, bonded or laminated into it. Felt, GRP and EPDM each take a kerb well when they are sound, and each has its own detail at the upstand, which our guide to fitting a flat rooflight to GRP, felt and EPDM roofs sets out layer by layer. If the specific worry is an older felt extension, the short answer on whether a flat rooflight can go on a felt roof is a good place to begin.

What changes on a retrofit is age. A new membrane bonds cleanly to a new membrane. A covering that has spent years in sun and frost has become less flexible, may have lost its surface finish, and may already be lifting at the edges. Joining fresh material to it is possible, but the join is only as durable as the older side.

The rule: if the covering is sound, the kerb is cut in and the membrane is dressed up it. The exception is a covering near the end of its life, where cutting a hole and joining to it spends effort on a surface that will need renewing soon anyway; then the sensible order is to renew the covering and fit the rooflight in the same visit.

That judgement is made on the roof, and it is given as a choice with reasons, not as an upsell. A sound covering takes a kerb without any wider work.

Finding the joists you actually have

Flat roof joists are not trusses, but the principle from the estate pitched roofs still applies: size the opening to the structure where you can. Joists on a flat roof extension are laid side by side at regular centres and span from wall to wall, or from a wall to a beam. A rooflight whose kerb sits between two of them leaves every joist whole.

On an existing roof the joist positions are found, not assumed. A builder may have spaced them to suit a board length, doubled one under a partition, or turned the span to suit the walls, and none of that shows from the top of the covering. The survey locates them from inside where possible, and the opening is marked out from the real positions once the deck is exposed. Our guide to joist spacing and the flat rooflight sizes that fit between has the width table for that step.

Where the rooflight you want is wider than the gap, one or more joists are cut and the ends are carried on trimmers. That is ordinary carpentry, but on an existing roof it is done from above through an open deck, with the loads worked out first. If the concern is strength, the answer page on whether a flat rooflight will weaken a flat roof covers it directly.

Warm deck, cold deck and the kerb in between

An older extension around Basingstoke may be a cold deck: insulation laid between the joists at ceiling level, a ventilated void above, and the deck and covering on top. A newer one, or a roof re-covered more recently, may be a warm deck, with rigid insulation board laid over the deck and the membrane over that.

The difference matters at the kerb. On a warm deck the kerb has to be insulated up to the level of the board so there is no cold strip around the frame. On a cold deck the opening passes through the ventilated void, so the sides of the shaft need lining and insulating, and the ventilation path around the opening has to stay open. Either can take a rooflight; they just need different details. Our guide on insulation at the kerb explains where condensation forms when that detail is missed.

Sometimes the survey finds a roof with very little insulation at all. Adding a skylight is a natural moment to raise that, and it is the owner's decision whether to deal with it now or later.

Upstand or ready-made kerb on an old roof

A flat rooflight sits on a raised kerb so that rain on the roof never reaches the glass seal. On a retrofit the kerb is either a timber upstand built on site to the opening, or a factory kerb that arrives insulated and is fixed down over the cut. Both lift the frame clear of the finished roof surface and give the membrane something to climb.

The choice on an existing roof often comes down to what is found once the deck is open: an out-of-square opening between old joists is simpler to meet with a timber upstand, while a clean opening at a standard size suits a factory kerb. The trade-offs are compared in timber upstand or factory kerb for a flat rooflight.

How the work runs on the day

A retrofit is planned so that the roof is open for as short a time as possible and never left open overnight. A typical sequence looks like this.

  1. Protect the room. Floor and furniture below the opening are covered, and the work area inside is sheeted before any cutting starts.
  2. Mark and cut the covering. The opening is set out from the joist positions and the membrane is cut back neatly, leaving enough sound material to join to.
  3. Open the deck. The boards are cut, the joists are exposed, and the opening is checked against what the survey expected.
  4. Trim if needed. Where the design calls for it, joists are cut and carried on trimmers before the opening goes any wider.
  5. Build or fix the kerb. The upstand is built or the factory kerb is fixed down, with insulation brought up to meet the roof build-up.
  6. Dress the membrane. The covering is taken up the kerb and bonded, welded or laminated to the existing roof so the join is continuous.
  7. Fit the unit. The rooflight is set on the kerb and fixed, and the roof is weathertight from this point.
  8. Finish inside. The shaft is lined, the ceiling edge is made good and the room is cleaned.

Some rooflights can be fitted largely from inside once the opening exists, which helps where outside access is awkward; whether a flat rooflight can be fitted from inside covers where that works.

Single storey rear extension with a flat rooflight set on a new kerb in an existing felt roof
A new kerb joined into an existing flat roof covering on an estate extension

Falls, outlets and where the kerb should sit

An existing flat roof already has its falls, even if they are gentle. Water runs from the high edge to a gutter or outlet, and any kerb standing in that path makes the water divide around it. On a new roof the falls can be designed around the rooflight. On an old one the rooflight is placed to suit the falls.

In practice that means keeping the kerb out of the main run to an outlet, and away from the lowest corner where water collects after heavy rain. Where the room below really needs the light in an awkward spot, a small tapered build-up on the high side of the kerb can turn water around it. Where the roof already ponds, that is worth sorting as part of the job rather than building a kerb into a puddle.

Inside the room: ceiling, reveal and light

The part of the job the household sees every day is the ceiling. Cutting a new opening through an existing plasterboard ceiling means a neat new edge, a lined shaft up to the frame, and a finish that matches the rest of the room. The shaft can be square or splayed; a splay spreads daylight more widely across the room, which suits a deep extension where the light has to travel. The options are in splayed or square reveals under a flat rooflight.

Lights, speakers and smoke detectors already in the ceiling sometimes sit where the opening wants to go. The survey notes them, and the position is chosen either to miss them or to move them as part of the work.

Building Control on a retrofit

Cutting a new opening in an existing roof changes the structure and the thermal envelope, so the work falls under the Building Regulations. Everlight notifies Building Control where the job is notifiable, and trimmed openings are carried out to the calculated details. Planning is a separate question and usually a simple one for a flat extension roof, but position, height and the house's own status all play a part. The fuller answer on whether flat rooflights need Building Regulations approval goes through the detail.

A flat rooflight on a single-storey rear extension
Figure 2 A flat rooflight on a single-storey rear extension

What to decide before the survey

You do not need a specification before anyone visits, but a few thoughts help the survey go further. Where in the room do you want the light to fall? Do you want the rooflight to open for air, or is it purely for daylight? Is the roof covering one you already had doubts about? And is there anything planned for the room below, such as a new kitchen layout, that might move where the light is most useful?

With those answers, the visit can go straight to whether the idea fits between your joists, what the covering will take, and whether renewing it at the same time is worth considering. The written quote that follows sets out the rooflight, the kerb, any trimming and the finish inside, and the installation is covered by our 10-year workmanship guarantee, which is not insurance backed.

For pitched roofs elsewhere on the house, the skylight installation overview for the Basingstoke area shows the other routes. For this roof, arrange a survey of the existing roof and we will tell you what the covering and joists will take before any work is priced. The flat rooflight service page has the rest of the picture.

Free roof survey

Tell us about your roof

  • Survey before any quote
  • No obligation
  • Plain-English advice

Say what you have in mind and where. We survey the roof before we quote, then tell you plainly what fits.

Prefer to talk? 01256 213206

Request my survey