Felt garage roofs, felt kitchen extensions and felt-covered link blocks between semis are all familiar sights on the estates around Basingstoke, and each can take a skylight. How the whole flat roof job is planned, from the opening in the deck to the finish inside, sits on our flat roof rooflight installation page. This answer stays with one question: what changes when the covering you are cutting into is bitumen felt.
Felt is a family, not one material
"Felt roof" covers several generations of bitumen roofing, and they behave differently when a new opening is formed in them. The older kind is built up from layers of bitumen felt laid in hot bitumen, usually finished with stone chippings or a mineral cap sheet. The newer kind is a reinforced bitumen membrane, laid as a base layer and a cap sheet, often torched on or bonded with adhesive. Both are waterproof sheets that bond to bitumen, so both can be dressed up an upstand and lapped properly.
| Covering | How to recognise it | What it means for the rooflight |
|---|---|---|
| Older built-up felt | Layers of felt, often with loose or bedded chippings on top | Chippings are cleared back from the opening so new felt bonds to a clean surface, then the upstand is felted in layers to match |
| Mineral cap sheet felt | Sheet finish with a gritty, coloured surface and visible laps | New cap sheet is lapped onto the existing sheet around the upstand, keeping laps shingled with the fall |
| Reinforced bitumen membrane | Thicker, flexible modern sheet in two layers, neat welded laps | The easiest felt to work with: base layer and cap sheet are both carried up the kerb and bonded |
Flat rooflight on an insulated upstand
- Double glazed rooflight, set to a slight fall so rain runs off the glass
- Upstand (kerb): a timber kerb with insulation on its outer face
- Membrane dressed up the upstand and over the top, sealed under the rooflight frame
- Waterproof membrane covering the roof, falling towards the gutter outlet
- Insulation laid over the deck, keeping the structure warm
- Roof deck on tapered firrings, which create the fall
- Joists, trimmed around the opening with trimmer joists
- Plasterboard reveal lining the opening, meeting the ceiling below
How the felt meets the rooflight
A flat skylight is never bedded straight onto the felt surface. It sits on an upstand, either a timber one built on the deck or a factory kerb, so the glass is raised clear of standing water and the felt has a vertical face to turn up. The felt runs up that face and over the top edge, and the rooflight frame then covers the top of the felt so the lap is shielded from rain. Whether a timber upstand or a factory kerb suits your roof is weighed up in our guide on timber upstand or factory kerb, and the short case for having one at all is in does a flat rooflight need a kerb?
- Open the covering. The felt is cut back neatly around the marked opening and the deck is cut between the joists.
- Form the upstand. The timber upstand is built, or the kerb fixed, and any insulation for the kerb goes in.
- Felt the upstand. New felt is bonded to the existing sheet and dressed up the upstand, with corners folded and sealed so no seam faces the fall.
- Fit the rooflight. The frame is fixed down over the felted upstand, covering the top edge of the felt.
- Finish inside. The opening is lined and made good, ready for decoration.
When the age of the felt changes the answer
New felt bonds well to sound felt. It bonds badly to felt that is brittle, blistered, crazed or lifting from the deck, because the weak point simply moves from the old sheet to the join between old and new. So the survey looks hard at the covering within reach of the opening, and at the deck underneath where it can be seen from inside.
The rule: a rooflight goes into felt that is sound around the opening, lapped into it directly. The exception: if the covering is near the end of its life, the better plan is to fit the rooflight at the same time as the roof is re-covered, so the upstand is felted in as part of one new, continuous membrane.
That second route is often the sensible one on a 1970s or 1980s garage or extension roof, where the felt may well be original. Timing the two together also means the fall of the new covering can be set to carry water past the upstand, which is covered in our guide to drainage falls around a flat rooflight.
Felt compared with the other flat roof coverings
Felt is not harder to work with than GRP fibreglass or EPDM rubber; each simply has its own way of being turned up an upstand. GRP is laminated up the kerb in resin, EPDM is dressed up with a compatible trim and adhesive, and felt is bonded in bitumen. What matters is that the upstand is finished in the same material family as the roof, so the two bond to each other. The detail for all three, side by side, is set out in fitting a flat rooflight to GRP, felt and EPDM roofs.

What to check on your own roof first
Before the survey, a quick look from an upstairs window or a ladder at the eaves tells you a lot. Note whether the surface has chippings, a gritty cap sheet or a smooth modern membrane. Look for bubbles, splits along the laps and places where water stands after rain; ponding can be a sign the deck has sagged, and our answer on why water sits on a flat rooflight explains how the kerb and fall deal with it. If you are unsure whether the joists can take an opening, will a flat rooflight weaken my flat roof? covers the structure.
None of that needs to be settled by you. We look at the felt, the deck and the joist spacing in person before any figure is written down, then say whether the rooflight laps into the existing covering or is better timed with a new one. For the wider picture of daylight on houses across the borough, our rooflight and skylight installation in Basingstoke page is the starting point. To find out which route your felt roof suits, arrange a survey of the roof.