Question answered · Flat roof rooflights

Can a flat rooflight go on a flat roof dormer?

The short answer

Yes, in most cases. A flat roof dormer is a small flat roof like any other, so a flat rooflight can sit on it on a raised kerb, angled to shed water. What decides it is room: the dormer roof has to be big enough for the kerb, a clear margin to every edge and the fall to the gutter, and the opening has to land between the dormer joists or be trimmed to a design.

A flat-roofed dormer with a rooflight

Dormers are common on the loft conversions of Basingstoke's estate houses and on older cottages in the villages around it, and a dormer roof is often the only flat surface up there. Putting glass into it brings daylight straight down into the part of the loft room the dormer window itself cannot reach. The general method is set out on our flat roof rooflight installation page; this answer covers what is particular to a dormer.

Why a dormer roof works for a rooflight

The front window of a dormer lights the floor near the front face and very little behind it. A rooflight in the dormer top lets sky light fall vertically into the middle of the room, over a bed, a desk or the head of a loft stair. On a dormer that faces north, or one overlooked by a neighbouring house, that overhead light can be the brighter of the two, because a skylight sees the open sky rather than the building opposite.

The dormer roof is also usually easy to reach from the room below once the ceiling is opened, and its covering (felt, GRP or EPDM on most conversions) takes a kerb and a flat rooflight in the same way a single storey extension roof does, with the membrane dressed up the kerb sides.

Flat rooflight on an insulated upstand A section through a flat roof. Joists carry firrings, a deck, insulation and a waterproof membrane that falls towards a gutter at the edge. Around the opening an insulated timber upstand rises above the roof, the membrane is dressed up it and sealed under the rooflight frame, and the double glazed rooflight sits on top with a slight fall so rain runs off the glass. Inside, plasterboard lines the reveal of the opening down to the ceiling of the room below. OutsideRoom below12345678

Flat rooflight on an insulated upstand

  1. Double glazed rooflight, set to a slight fall so rain runs off the glass
  2. Upstand (kerb): a timber kerb with insulation on its outer face
  3. Membrane dressed up the upstand and over the top, sealed under the rooflight frame
  4. Waterproof membrane covering the roof, falling towards the gutter outlet
  5. Insulation laid over the deck, keeping the structure warm
  6. Roof deck on tapered firrings, which create the fall
  7. Joists, trimmed around the opening with trimmer joists
  8. Plasterboard reveal lining the opening, meeting the ceiling below

The three things a dormer can limit

Where a dormer roof sets the limits for a flat rooflight
LimitWhy it matters on a dormerWhat the survey measures
Roof areaThe kerb needs clear roof round it, and the dormer top is bounded by the main slope, two cheeks and the front edgeThe usable flat area once the abutment with the main roof and the edge trims are allowed for
Joist direction and spacingThe opening either fits between two joists or needs trimmers carrying the cut joistWhich way the dormer joists run, their depth and the actual gap between them
Fall and drainageWater has to run round the kerb and off the front edge without pooling against the main roofThe existing fall, where the water leaves the dormer and where the kerb can sit clear of that path

The joist question has a plain answer. If a standard size fits between two joists, no timber is cut. The widths that suit common joist gaps are listed in joist spacing and the flat rooflight sizes that fit between. If the opening is wider, the joist it interrupts is trimmed, and on a dormer that trimming is designed, not improvised, because the dormer roof often carries the load of the cheek walls and the front frame too.

Where on the dormer the glass should go

Placement is where a dormer differs most from a larger flat roof. Keep the rooflight too close to the junction with the main pitched roof and the kerb sits in the corner where water and debris gather, next to the flashing that seals the dormer to the slope. Push it too far forward and it crowds the front edge, the gutter and the fascia.

The rule: set the kerb in the middle band of the dormer roof, clear of the back abutment and the front edge, with the water able to run past it on both sides. The exception is a dormer so shallow front to back that no middle band exists; there a smaller unit, or a different source of light such as a roof window in the main slope beside the dormer, is the honest recommendation.

The kerb also has to lift the glass enough for rain to clear it. A flat rooflight is always fitted at a slight angle; the figure and the reasons sit in our answer on the minimum pitch for a flat rooflight.

Inside the loft room

A dormer ceiling is often close to head height already, so the depth of the shaft between the roof deck and the ceiling is shallow. That is good for daylight, since a short shaft loses little light, but it leaves limited room for insulation around the lining, and the insulation line has to run unbroken from the roof into the kerb. Splayed reveals can widen the pool of light on a low ceiling. The sequence for cutting into a finished room and making good afterwards is covered in adding a flat rooflight to an existing flat roof.

Loft bedroom under a flat dormer roof with daylight from a rooflight above the bed
A flat rooflight in a dormer top lights the middle of a loft room

Getting the answer for your dormer

  1. Look from inside. Note how far the dormer ceiling runs front to back and where you want the light to land.
  2. Survey. We measure the roof area, joist direction and spacing, the fall and the condition of the covering before any quote is written.
  3. Specify. One of three outcomes: a unit that fits between the joists, a smaller unit to suit a shallow dormer, or a wider opening trimmed to a design.
  4. Install and seal. The kerb is formed, the covering is dressed up it and the rooflight fixed, with the lining finished inside.

The workmanship on the finished dormer carries a 10-year guarantee (not insurance backed). If you are concerned about the roof itself, will a flat rooflight weaken my flat roof? deals with that directly. To find out whether your dormer top has room for glass, arrange a survey of the dormer and we will measure it before suggesting a size.

Free roof survey

Tell us about your roof

  • Survey before any quote
  • No obligation
  • Plain-English advice

Say what you have in mind and where. We survey the roof before we quote, then tell you plainly what fits.

Prefer to talk? 01256 213206

Request my survey