A lightwell is a hole with a purpose. It is the open shaft cut down beside a basement so that a window at the bottom can see the sky, or the gap left between a new extension and the old house so that a middle room keeps some daylight. It works, but it takes floor away from the garden or terrace above it, it collects leaves, and it needs a railing or a grille to stop someone stepping into it. Put walk-on glass over the top and the ground comes back while the daylight keeps falling. This guide is about that one job: capping a lightwell with glass you can walk across, and the handful of decisions that make it go well.
It sits under our walk-on rooflight installation service, which covers the whole family of trafficable glass. Here the focus is narrower: the shaft itself, what happens to the space underneath once it is covered, and why a cover over a lightwell is a different animal from a walk-on skylight set into a flat roof.
Where lightwells turn up around Basingstoke
Lightwells follow cellars and basements, and cellars follow age. The Victorian and Edwardian terraces of Reading and Caversham, and the older villas in Aldershot, are the local houses where a front area or a cellar window below ground level is part of the original design. The post-war estates that make up so much of Basingstoke itself were built on slabs and suspended floors with no cellar at all, so a lightwell on a Popley or Brighton Hill house is almost always something new: a basement dug under an extension, or a courtyard gap designed into a rear addition.
That split matters because the two situations start from different places. An old front area has walls that have stood for a long time, a drain at the bottom that may or may not still work, and neighbours on either side whose walls it may share. A new lightwell is being designed now, so its walls, its drainage and the frame the glass will sit on can all be drawn together from the start. The glass and the fitting are similar in both cases; the groundwork before it is not.

How a walk-on rooflight sits in a terrace
- Anti-slip fritted top surface, so the glass is safe to walk on when wet
- Laminated glass: several layers bonded with interlayers, so it stays in place if a layer breaks
- Sealed cavity between the laminated glass and the inner pane
- Inner pane, completing the insulated unit
- Frame carrying the glass, sealed at the edges
- Kerb around the opening, bedded to the roof structure
- Waterproofing dressed up the kerb and under the frame
- Paving on pedestals, finished level with the glass
Open below or enclosed below: the first decision
Before anyone talks about glass thickness, one question settles the specification: once the glass is on, is the shaft underneath still outside, or has it become part of the house?
If the lightwell stays external, the glass is a weather cover and a floor. Rain is kept off, but the air in the shaft is still outdoor air, the basement window at the bottom is still an external window, and the walls of the shaft are still external walls. If instead the lightwell is being enclosed, so that the basement room extends into it or the shaft becomes a glazed void inside the building, the glass is now part of the thermal envelope and has to insulate like any other rooflight. That second route usually means an insulated walk-on unit and a thermally broken frame, and it changes how Building Control looks at the work.
| Question | Lightwell stays external | Lightwell enclosed into the house |
|---|---|---|
| What the glass is doing | Carrying foot traffic and shedding rain over an outdoor void | Carrying foot traffic and forming part of the insulated roof of a room |
| Glass type | Laminated walk-on glass; an insulated unit is optional | Insulated walk-on unit with a laminated structural lower layer |
| Frame | Galvanised or stainless steel, or a proprietary walk-on frame | Thermally broken frame tied into the insulation of the surrounding floor or roof |
| Air in the shaft | Needs to keep moving; vents or gaps stop it going stale and damp | Heated room air, so the glass surface temperature matters |
| Water at the bottom | Wind-driven rain and splash still reach the floor of the shaft; its drain stays in use | The shaft floor becomes an internal floor; any old drain is sealed or diverted |
| Regulations in play | Safety of the walking surface and any effect on escape or ventilation from the basement | All of that plus thermal performance of the new roof element |
There is no wrong answer here, only a choice to make early. A cover over an open shaft is simpler. Enclosing the shaft buys floor area inside, at the cost of a more demanding glazed unit and more detail at the edges.
What the glass sits on
A lightwell cover rests on the walls of the shaft, so those walls are now carrying a floor. On a new basement they will have been designed for it, or can be. On an older front area, the retaining walls were built to hold back soil, not to take a bearing along their top edge, so the survey checks what is there: the thickness and condition of the brickwork, the state of any coping, and whether a new concrete or steel bearer is needed to spread the load evenly around the opening.
The frame itself is usually a steel angle or a proprietary walk-on frame set level on that bearing, with packers and a resilient strip so the glass never touches hard metal or masonry. Across a wide lightwell the glass may be split into panels over a steel intermediate beam, which keeps each pane within the size its load rating allows. Our guide to the structure a walk-on rooflight sits on goes through the bearing details in full; for a lightwell the short point is that the shaft walls are the structure, so they are looked at first.
The rule: the glass is only as sound as the edge it bears on, so the walls of the shaft are checked before a pane is ordered. The exception: where a structural engineer has already designed the lightwell as part of a new basement, the bearing is drawn on the plans and the survey confirms it matches what was built.
Level with the ground, or raised on a kerb
The usual aim is a lightwell cover that disappears into the path, patio or terrace around it, with nothing to trip over. That is possible, and it is the reason walk-on glass is chosen over a grille. A flush cover needs the frame recessed so the top of the glass finishes level with the surrounding paving, a gap or channel at the edge to catch surface water, and a slight fall in the paving away from the glass so rain does not pool on it.
A raised cover, with the glass sitting on a low kerb above the surrounding ground, keeps water out more easily but becomes a step. In a front garden that may be fine if the cover sits beside the path rather than in it. On a terrace it is usually the wrong answer. The trade-offs are set out in our guide to flush or upstand walk-on rooflights, and at ground level the paving contractor and the glazing installer need to agree the finished levels before either starts.
A lightwell cover is judged by the path around it: if you notice the edge, it was set at the wrong height.
Water, air and the bottom of the shaft
Covering a lightwell changes the way water and air move through it. With an open shaft, rain falls in and runs to a gully at the bottom. With glass over the top, the rain is shed across the surface instead, so it has to go somewhere: into a slot drain, into the paving falls, or onto a bed that soaks it away. That route is planned before the frame goes in.
The shaft does not become bone dry once capped. Wind still drives rain through any ventilation gaps, splash from the paving still reaches the edges, and moisture from the ground still comes through old walls. So the drain at the bottom of an external lightwell stays in service and needs to be reachable. The shaft also needs air: a sealed box over damp masonry gathers condensation on the underside of the glass and on the basement window. Ventilated edges or a small permanent vent in the frame keep it breathing. If the space below is enclosed and heated, the concern shifts to the inside face of the glass, and our answer on whether walk-on rooflights get condensation covers why the insulated unit and room ventilation deal with it.
For the seal where the frame meets the paving or roof finish, the detail depends on what surrounds the glass; our waterproofing guide owns that subject.
Escape, ventilation and the basement below
This is the part of a lightwell job that is easy to overlook. A basement room with a window into a lightwell may rely on that window for fresh air, and in some layouts for a way out in a fire. A fixed sheet of glass over the top of the shaft can take away both. Building Regulations deal with means of escape from habitable rooms, and a basement bedroom or living room is where that question bites hardest.
There are several ways to keep both. The cover can be part fixed and part openable, with a hinged or lifting panel that can be pushed up from below. The shaft can keep permanent ventilation gaps at its edges. Or the escape route can be provided elsewhere, which is a design decision for the whole basement rather than the glass alone. What matters is that the question is asked before the cover is specified. Our answer on whether walk-on rooflights need Building Regulations explains how notification works for this kind of glazing; where the work is notifiable, we submit it to Building Control ourselves.
- Look at the room below. What is the basement used for, and does its window into the lightwell open?
- Check what that window does. Is it the room's ventilation, its escape route, or only its daylight?
- Choose the cover to match. Fixed glass where the window only brings light; an opening or ventilated panel where it does more.
- Agree it with Building Control. The notification describes how escape and ventilation are kept.
Load, grip and what walks across it
A lightwell cover at the front of a house may take more than foot traffic. Bins get wheeled across front paths, and a delivery trolley may use the same route. The load rating is set by what will realistically cross the glass, and the manufacturer designs the laminated build-up to that rating. The ratings and the classes they are expressed in are explained in our guide to walk-on rooflight load ratings, and if you want the short version, our answer to can you really stand on a walk-on rooflight puts it in a paragraph.
Grip matters more at ground level than on a roof terrace, because a front path is used in all weather, often in a hurry, in shoes carrying mud and leaves. A textured or fritted top surface is the usual answer, and the choice between patterns is set out in our guide to slip resistance on walk-on glass. A lightwell cover next to a front door also faces the street, so a patterned surface does double duty: it grips, and it softens the view down into the basement from the pavement.
How large a lightwell can be covered
A narrow front area can often take a single pane. A deep courtyard lightwell beside an extension may need several panes over intermediate steels, because every walk-on unit has a maximum size for its rating and a single sheet gets very heavy to lift into place. More panes mean more joints, and every joint is a line that has to be sealed and kept clean, so the layout balances pane size against the number of joints. Our answer on how large a walk-on rooflight can be covers the limits in general terms; for a lightwell, the shaft width and the access to lift glass in are what usually decide the split.

Keeping the glass and the shaft clean
A glass lid on a lightwell has two faces to keep clean, and the lower one is at the bottom of a shaft. From above, walk-on glass cleans like any hard floor: sweep off grit before it gets trodden in, then wash with water and a soft brush. The underside of an external cover gathers cobwebs and dust in the damp air of the shaft, and the gully at the bottom collects whatever blows through the vents. So a lightwell cover works best with a way in: a lifting panel, a hinged section, or a removable pane on a frame designed to be opened with the right tools. Our answer on how to keep walk-on glass clean has the routine for the top face.
Planning and the front of the house
A cover over a rear lightwell is usually a quiet change. A cover in a front garden is visible from the street, and in a conservation area, or on a listed building, the local planning authority may take an interest in anything that alters the front of the house. The Victorian terraces in Reading and Caversham fall under Reading Borough Council, and the village cores around Basingstoke sit in conservation areas under their own councils. Whether consent is needed depends on the house and where it stands, and any application is judged by the council on the proposal in front of it. The survey notes whether the property sits in a conservation area so the question can be put to the council early.
From survey to finished cover
The order on site follows the decisions above. The survey measures the shaft, looks at the walls, the drain and the basement window, and asks what the room below is used for. That produces a specification: open or enclosed below, fixed or partly openable, flush or raised, one pane or several, and the load and grip the cover needs. The glass is made to order, so the bearing, drainage channel and any steels are prepared while it is being made. On fitting day the frame is set level, the panes are lowered in on protected bearings, the edges are sealed and the surrounding finish is made good to the new levels.
Because the glass is manufactured to measured sizes, nothing is ordered until the shaft has been surveyed; a written quote follows that visit. The installation is backed by our 10-year workmanship guarantee, which is not insurance backed. If your lightwell sits over a flat roof rather than at ground level, the flat roof rooflight hub is a useful companion, and for everything else on trafficable glass, head back to the walk-on rooflight service. When you are ready for someone to look down the shaft with you, arrange a survey of the lightwell.