People want this for different reasons: daylight to find things by, a brighter space to work in when the tanks or the wiring need attention, or a first step towards a conversion later. Whatever the reason, the same roof-first thinking behind our rooflight and skylight fitting across Basingstoke applies here. Start with what the loft is built from, then choose a window that suits both today's use and whatever the space might become.
What an unconverted loft changes about the job
In a converted loft or a bedroom with a sloping ceiling, a roof window has to be lined, insulated around and finished to the standard of a living room. In a loft that is still open timbers, most of that disappears. The installer works from inside, between the rafters or trusses, with the underside of the roof in plain view. The window sits in the slope, the covering outside is opened up and closed around a flashing kit, and inside there is often no more than a simple timber lining or none at all.
What does not disappear is the need to work safely up there. Ceiling joists in an unconverted loft are not a floor, so boards are laid across them before anything else happens, and the loft hatch sets a limit on the size of window that can be passed up from below. Where the hatch is small, the unit may go in from outside instead, which is one of the things a survey settles early.

Sizing a roof window to the truss bays
- Fink trussed rafter, factory made and designed to work as one whole frame
- W-shaped webs, joined at every node by pressed metal nail plates
- Tile covering on battens over the underlay
- Roof window set in the slope, fitted between trusses so the frame is untouched
- Narrow roof window sitting in the bay between two trusses
- Trusses at even 600mm centres along the roof
- No truss cut: the trusses either side of the window stay whole
- A wider window crosses a truss, so the cut needs designed trimming from an engineer or the truss maker
Trusses or rafters: what decides the width
Most houses around Basingstoke built from the 1960s onwards have trussed rafter roofs, and in an open loft you can see them for yourself: slim timbers in a repeating triangle, joined by flat metal plates, usually at 600mm centres. In that roof the sensible choice is a window narrow enough to sit between two trusses, so every truss stays whole. A wider opening is only made to a written trimming design, never by cutting a web or a chord to see what happens.
Older houses in the villages and town centre streets tend to have cut rafter roofs, built on site from separate rafters, purlins and a ridge. The spacing there varies, and trimming a rafter is a familiar carpentry job, but it is still measured and planned first. If you are not sure which kind of roof sits above your ceiling, our answer on whether a skylight can go in any roof explains the signs.
| Loft roof | Usual first choice | When more light is wanted |
|---|---|---|
| Trussed rafters at 600mm centres | A narrow roof window that fits between two trusses, left uncut | A taller window of the same width, or a second one in the next bay |
| Cut rafters, spacing varies | A width chosen to suit the measured gap between rafters | A wider opening with planned trimmers either side |
| Low pitch or shallow loft | A window rated for that pitch, confirmed at survey | A second unit rather than a larger one, where headroom is tight |
A cold loft and a glass unit
In most houses the insulation is laid on the ceiling of the rooms below, which leaves the loft itself unheated. A rooflight in that space is therefore not keeping warmth in so much as keeping weather out, and heat loss through the glass matters less than it would over a bedroom. What matters more is moisture. Warm, damp air from the house finds its way up through the hatch and around downlights and pipes, and it can condense on the coldest surface it meets. A modern double glazed unit runs warmer on the inside face than single glazing or an old plastic dome, which helps.
The rule: keep the existing loft insulation and ventilation working as they were, and do not let the window become a route for warm air to pour in and sit against cold glass. The exception is a loft you expect to convert soon, where it can make sense to choose a unit and a lining that will suit a warm room later.
Keeping the hatch closed and sealed, and not blocking the eaves vents when boards go down, does as much as the window itself. The causes and the fixes are set out in our answer on why skylights get condensation.
Planning ahead for a conversion
If there is any chance the loft becomes a room, place the window as if it already had. A skylight fitted purely for storage light can end up in the wrong bay once a staircase, a dormer or a new floor level arrives, and moving it later means a second opening and a second set of flashings. Think about where a bed or desk would go, where the head height will be once a floor is built up over the joists, and which slope gets the best daylight for the room you picture.
A converted loft also brings rules an unconverted one does not, such as fire safety and escape routes, which the conversion designer and Building Control deal with as part of that project. A window fitted now will not settle those questions on its own, but choosing a sensible size and position keeps the options open. Which window shapes suit which house types, from estate semis to chalet bungalows, is covered in our guide to skylights by house type.
Permission and Building Control
A roof window in the slope of an ordinary house is usually treated as permitted development, as long as it stays within the projection limit and the house is not in a conservation area or otherwise restricted. The Building Regulations side is separate from planning: adding a new rooflight is controlled work, and where it needs notifying, that paperwork is part of our job rather than yours. Our answer on whether skylights need Building Regulations approval goes through when it applies, and the projection and height limits are explained in the permitted development guide.
How the fitting runs in an open loft
- Look first. We survey the roof before quoting: the timbers, the spacing where you want the window, the pitch, the covering and how the unit will get up there.
- Make the loft safe. Boards go across the joists around the work area, and anything stored nearby is moved clear.
- Open the roof. Tiles or slates are lifted, the felt and battens are cut back to the opening, and the frame is fixed between the timbers.
- Weather it. The flashing kit suited to your covering goes on and the tiles are laid back around it.
- Finish inside. A simple lining or trim to suit a storage loft, or a fuller finish if a conversion is planned, then the loft is swept and cleared.
The work is covered by a 10-year workmanship guarantee, which is not insurance backed. For a closer look at the roof window side of the job, see our roof window installation page, and when you want to know what your own loft allows, arrange a survey of the roof and we will measure it with you.