Question answered · Rooflights and skylights

Can a skylight go in a lean-to extension roof?

The short answer

Usually, yes. A lean-to extension roof takes a skylight well, provided the slope is steep enough for the window you choose and the rafters leave room for it. A tiled lean-to at a reasonable pitch takes a pitched roof window between its rafters. A shallow or nearly flat lean-to suits a rooflight on an upstand instead. The survey decides which, by measuring the pitch and the timbers.

A rear extension with rooflights

A lean-to is the single slope that runs off the back wall of the house: the kitchen extension on a 1970s semi, the garden room on a bungalow, the utility at the side of a village cottage. Because the room under it is often the darkest in the house, it is one of the first places owners around Basingstoke think about opening up. Our skylight and rooflight fitting work across Basingstoke covers this roof as often as any main roof, and the answer turns on three things you can partly check yourself.

Pitch decides the kind of skylight

Every pitched roof window has a minimum pitch set by its maker, and the flashing kit for a tiled roof has its own limits too. A lean-to built with a decent fall, finished in the same tile or slate as the house, normally sits comfortably within them. The trouble comes with the shallow lean-to, built low so it clears the bedroom window above, where the slope is too gentle for a standard roof window and its flashing to shed water as designed.

On that kind of roof the better choice is usually a flat-roof style rooflight fixed on a raised kerb, with the roof covering dressed up the sides of the kerb. That is a different product with a different detail, and it is the right one for the slope rather than a compromise. You can see how that route works on our flat roof rooflight installation page.

Lean-to roof types and the skylight each one suits
Lean-to roofUsual choiceWhat gets checked
Tiled or slated, good fallPitched roof window between the raftersPitch against the window maker's minimum, rafter spacing, tile profile for the flashing
Tiled, very shallow fallRooflight on an upstand, or a low-pitch roof window where the maker allows itWhether the tiles themselves are laid within their own limits
Felt, membrane or single-ply, near flatFlat rooflight on a kerbDeck condition, fall to the gutter, how the covering will be dressed to the kerb
Polycarbonate or glazed sheetOften better as a solid, insulated roof firstWhether the frame is a structure that can carry a window at all
Sizing a roof window to the truss bays On the left, a section through a pitched roof built from Fink trussed rafters, with W-shaped webs joined by nail plates, tiles on battens, and a roof window set in the slope. On the right, the same slope seen square-on: trusses at even 600mm centres with a narrow roof window sitting in the bay between two of them, so no truss is cut. A wider window outline, drawn dashed, crosses a truss and would need designed trimming. Section600mm centresSeen square-on12345678

Sizing a roof window to the truss bays

  1. Fink trussed rafter, factory made and designed to work as one whole frame
  2. W-shaped webs, joined at every node by pressed metal nail plates
  3. Tile covering on battens over the underlay
  4. Roof window set in the slope, fitted between trusses so the frame is untouched
  5. Narrow roof window sitting in the bay between two trusses
  6. Trusses at even 600mm centres along the roof
  7. No truss cut: the trusses either side of the window stay whole
  8. A wider window crosses a truss, so the cut needs designed trimming from an engineer or the truss maker

The rafters in a lean-to

Unlike the main roof on an estate house, a lean-to is rarely built from factory trusses. It is usually cut on site: rafters running from a wall plate fixed to the house down to the outer wall, sometimes with a timber ceiling below and sometimes open to the room. That makes it a more forgiving roof for a skylight, because a single rafter can be trimmed in the traditional way, with doubled rafters and trimmers carrying the load round the opening.

What you cannot know from the garden is how far apart those rafters sit or how deep they are. A builder working on a small extension sets them to suit the span and the covering, so they vary from house to house. If the spacing matches a standard window width, the window drops between two rafters with nothing cut. If not, a short trimmed opening is normal carpentry on a lean-to. Our answer on whether a skylight can go in any roof covers the wider picture, including the trussed main roofs where the rules are stricter.

Where the lean-to meets the house

The top edge of a lean-to runs into the back wall of the house, and that junction is protected by a lead or similar abutment flashing tucked into the brickwork. A skylight placed too close to it crowds that detail and makes both harder to weather properly. The usual answer is to keep the window a sensible distance down the slope from the wall, which also tends to throw the daylight further into the room rather than onto the wall.

The rule: keep the rooflight clear of the wall abutment and of the gutter line at the bottom of the slope. The exception is a very short lean-to where there is only one sensible position; the survey then works out the flashing so both details are made properly, rather than squeezing one into the other.

Headroom matters as well. The low end of a lean-to can be tight inside, and an opening window placed there may swing into the space you walk through. Our answer on the best place for a skylight goes through how position changes the light and the way the room is used.

Insulation and the ceiling underneath

Many older lean-tos were built with thin insulation, or none, between the rafters. Cutting in a skylight means opening the ceiling, so it is a natural moment to look at what is up there. The new window needs lined reveals and insulation packed round the frame, and where the existing ceiling is poorly insulated the survey will say so plainly. Where a lean-to is open to the rafters with a boarded finish, the lining is matched to that rather than a plastered reveal.

Building Control and planning for a lean-to

Putting a new opening in a roof is building work that normally has to be notified, because it touches the structure and the thermal performance of the roof. We make that notification as part of the job, so you are not left filling in the paperwork. Our answer on whether skylights need Building Regulations explains what is looked at.

On planning, rooflights on a house generally sit under permitted development, within limits on how far they stand proud of the slope and where they go. Those limits and the exceptions, such as a conservation area or a listed building, are set out in our guide to skylight permitted development rules. In a conservation village, check the position with the council before anything is ordered.

How the survey settles it

  1. Measure the fall. The pitch of the lean-to is taken on the roof itself, because it decides between a roof window and a rooflight on a kerb.
  2. Look at the timbers. From inside or through the ceiling, the rafter size and spacing are checked where the window would go.
  3. Read the covering and the abutment. The tile, slate or membrane and the flashing against the house decide the flashing kit or the kerb detail.
  4. Agree the size and position. The window is sized to the room and the roof, not to the largest unit that would fit.

After that you get a written quote describing the product, the opening and the finish inside, and the fitting carries our 10-year workmanship guarantee. What happens on the day and what gets recorded is covered in what happens at a rooflight survey. If your kitchen or garden room sits under a lean-to and needs more daylight, ask us to measure the roof and we will tell you which kind of skylight it takes.

Free roof survey

Tell us about your roof

  • Survey before any quote
  • No obligation
  • Plain-English advice

Say what you have in mind and where. We survey the roof before we quote, then tell you plainly what fits.

Prefer to talk? 01256 213206

Request my survey