Planning is a fair first question when you want daylight in a loft, a landing or an extension, and on a typical Basingstoke estate house the answer is reassuringly short. The detail below sets out when that short answer holds, when it does not, and who decides. If you are weighing up the whole job rather than just the paperwork, our skylight installation around Basingstoke page shows how we approach a roof from the survey onward.
One point before the rules: planning permission and Building Regulations are separate systems. Planning asks whether the change to how the house looks is acceptable. Building Regulations ask whether the work is structurally sound, weathertight and thermally adequate. A rooflight can be free of the first and still fall within the second.
The permitted development conditions, in plain terms
Householder permitted development in England lets you alter a roof in some ways without applying to the council. Rooflights come under the class that covers other alterations to the roof, and the test is about shape and position rather than size or number of windows.
| Condition | What it means on the roof | Where it tends to matter |
|---|---|---|
| Projection | The glazing and frame must not stand more than 150mm beyond the plane of the roof slope | Raised kerbs and lanterns on flat extension roofs |
| Height | No part may rise above the highest part of the existing roof | Rooflights placed close to the ridge |
| Side slopes | A window in a roof slope facing the side boundary must be obscure glazed and non opening unless the opening part is over 1.7m above the floor | Semis and detached houses with hipped ends |
| House type | The rights belong to houses, so flats and maisonettes sit outside them | Converted buildings and purpose-built blocks |
A modern low-profile roof window sits well within the projection limit on tiles or slate, which is why a between-the-trusses loft window on a 1970s or 1980s semi rarely raises a planning question at all. The fuller wording, including how the measurements are taken, is in our guide to skylight permitted development rules.
Sizing a roof window to the truss bays
- Fink trussed rafter, factory made and designed to work as one whole frame
- W-shaped webs, joined at every node by pressed metal nail plates
- Tile covering on battens over the underlay
- Roof window set in the slope, fitted between trusses so the frame is untouched
- Narrow roof window sitting in the bay between two trusses
- Trusses at even 600mm centres along the roof
- No truss cut: the trusses either side of the window stay whole
- A wider window crosses a truss, so the cut needs designed trimming from an engineer or the truss maker
When a planning application or consent comes into it
Permitted development is a default, and several things can take it away or add a separate layer of consent on top.
- Listed buildings. Listed building consent covers works to a listed house inside and out, whether or not planning permission is needed, so a new rooflight on a listed cottage goes to the council first.
- Article 4 directions. A council can withdraw specific permitted development rights in a defined area, and some conservation areas carry a direction that brings roof alterations back under control.
- Estate conditions. Some newer estates were approved with a planning condition removing permitted development rights for the houses on them. The original planning permission for the estate shows whether that applies.
- Flats and maisonettes. With no householder rights, a new rooflight in a flat roof above a flat needs an application.
- Flat roof lanterns. A lantern or a tall kerb can exceed the 150mm allowance; the difference between a flush rooflight and a lantern is explained in skylight or roof lantern: what is the difference?
Being in a conservation area on its own does not remove the rooflight allowance, but councils often expect a flush, low-profile unit on a visible slope, and the conversation is worth having before anything is ordered.
Villages, conservation areas and the councils around Basingstoke
The borough and its neighbours hold two very different kinds of roof. The post-war and newer estates, Popley, Brighton Hill, Chineham, Hatch Warren and Beggarwood among them, are trussed rafter roofs on ordinary houses where the permitted development route is usually the one that applies. The older villages and town centres, Old Basing, Overton, Kingsclere, Odiham and Hartley Wintney for example, contain conservation areas and listed buildings where the check comes first.
Which council you ask depends on where you live, not on the Basingstoke postcode. Basingstoke and Deane Borough Council covers the town and villages such as Old Basing and Overton, Hart District Council covers Hook, Odiham and Fleet, and West Berkshire Council covers Berkshire places such as Aldermaston, Thatcham and Newbury.
For a period roof in one of those villages, a conservation rooflight, with slim frames and a central glazing bar that sits down into the tiles, is the usual starting point for a proposal. Our conservation rooflight service covers how those units are specified and fitted.
How to check your own house
A few minutes of checking avoids the one situation nobody wants: a window fitted and then questioned.
- Confirm the building. Is it a house, and is it listed? The Historic England list can be searched by address.
- Look at the council map. Each council publishes its conservation area boundaries and any Article 4 directions on its website.
- Read the estate permission. On a newer home, the council's planning search shows the original approval and any condition on permitted development.
- Measure the idea against the table. Projection, height and side slope decide the rest.
- Ask for certainty if you want it. A Lawful Development Certificate from the council confirms in writing that the work is permitted development, which some owners like to hold when they come to sell.
Owners of recently built homes have a second document to read besides the planning file: the housebuilder warranty. That question is covered in can you add a skylight to a new build house?
Planning is one question, Building Control is another
Even where no planning permission is needed, a new rooflight usually involves Building Regulations, because cutting an opening alters the roof structure and the new glazing must meet thermal standards. On a trussed roof, a window chosen to fit between the trusses keeps the structural side simple, while a wider opening needs designed trimming. The regulations side is answered in do skylights need Building Regulations approval?, and the notification process itself in our guide to Building Control notification for rooflights, which is paperwork we take off your hands on notifiable jobs.
The rule: no planning permission does not mean no rules. The exception runs the other way too: a like-for-like replacement in the same opening often needs neither a planning application nor a structural change, though the glazing standard still applies.
Infographic
Planning and Building Control: the questions in order
Is the house listed?
Yes: listed building consent is needed before any rooflight goes in.
No: next question.
Is it in a conservation area, or a flat or maisonette?
Yes: check with the council. A conservation-style rooflight is often the expected choice.
No: next question.
Will it sit within permitted development limits?
Usually yes when it projects no more than 150mm from the roof plane and stays below the highest part of the roof.
If not: a householder planning application.
Is the work notifiable under the Building Regulations?
A new rooflight, or a replacement that changes the structure, is. We notify Building Control for you.
Either way the glazing must meet current thermal standards.
What we do about it at the survey
At the survey we look at the house type, the roof slope the window faces, the pitch and covering, and whether the property sits in a village centre or on an estate. We tell you which of the conditions above apply to your idea and which unit keeps it inside them. Where the answer rests with the council, because the house is listed, in an Article 4 area or under an estate condition, we say so plainly and give you the product details a planning officer will want to see. The decision itself belongs to the council, and we never promise an outcome.
If you would like the roof itself checked against these rules, arrange a survey of your roof and we will go through the planning position with you on the day, before any quote is written.