GuideRooflights and skylights

Building Control notification for a new or replaced rooflight

When a new or replacement rooflight is notifiable work, what building control checks, who lodges the notice and the certificate you should keep.

Measuring a roof opening during a survey
Measuring a roof opening during a survey

Cutting a hole in a roof and putting glass in it touches two things the Building Regulations care about: the timbers that hold the roof up, and the layer that keeps the heat in. That is why a new rooflight, and usually a replaced one, counts as work the local building control service should know about. This guide covers what makes the job notifiable, what the notification records, who sends it, and the certificate you should hold at the end. It is written for homes around Basingstoke, where the answer shifts with the roof: a trussed 1970s estate roof in Brighton Hill and a cut rafter cottage roof in Old Basing raise different questions on paper as well as on the scaffold.

One distinction first, because it causes most of the confusion. Planning and Building Regulations are two separate systems run by two separate teams, and a skylight can be fine under one while still needing the other.

Planning and Building Regulations are different questions

Planning deals with how the house looks from outside, how it affects neighbours and whether a change suits its surroundings. In the town itself that is Basingstoke and Deane Borough Council's planning team, and in the wider radius it is whichever district, borough or national park authority covers the address. A roof window that stays within the permitted development limits on projection and height often needs no planning application at all; the permitted development guide sets out those limits, and the short answer on whether a skylight needs planning permission covers the exceptions such as conservation areas.

Building Regulations are national technical standards. They do not ask whether the rooflight looks right; they ask whether the opening is structurally sound, whether the glazing keeps enough heat in, and, in a habitable loft, whether the room is safe. A rooflight that is permitted development is therefore not automatically clear of building control. Treat the two as separate boxes to tick (our skylight and rooflight installation page shows where each fits in a job), and ask whoever quotes which of them applies to your roof and who deals with each.

Sizing a roof window to the truss bays On the left, a section through a pitched roof built from Fink trussed rafters, with W-shaped webs joined by nail plates, tiles on battens, and a roof window set in the slope. On the right, the same slope seen square-on: trusses at even 600mm centres with a narrow roof window sitting in the bay between two of them, so no truss is cut. A wider window outline, drawn dashed, crosses a truss and would need designed trimming. Section600mm centresSeen square-on12345678

Sizing a roof window to the truss bays

  1. Fink trussed rafter, factory made and designed to work as one whole frame
  2. W-shaped webs, joined at every node by pressed metal nail plates
  3. Tile covering on battens over the underlay
  4. Roof window set in the slope, fitted between trusses so the frame is untouched
  5. Narrow roof window sitting in the bay between two trusses
  6. Trusses at even 600mm centres along the roof
  7. No truss cut: the trusses either side of the window stay whole
  8. A wider window crosses a truss, so the cut needs designed trimming from an engineer or the truss maker

Which rooflight jobs are notifiable

The trigger is not the size of the unit. It is what the work does to the building. Replacement glazing in a roof is treated much like a replacement window in a wall, and a brand new opening is an alteration to the roof structure as well. The table sets out the common domestic cases.

Rooflight work and how the regulations treat it
The jobWhy the regulations applyHow it is usually recorded
New roof window in an existing pitched roofA new opening alters the roof structure and the thermal envelopeNotified to building control before the roof is opened
Replacement roof window in the same openingThe new unit is a controlled fitting and must meet the current energy standardNotified to building control, or self-certified by an installer registered with a competent person scheme
New unit on an existing flat roof kerbReplacement glazing in the roof, judged on its thermal performanceAs for a replacement roof window
Wider opening in a trussed rafter roofTrusses are altered, so the trimming has to be designed and justifiedNotified, with a structural design to support it
Rooflight within a loft conversion or extensionPart of a larger project with fire, escape and insulation requirementsCovered by the main project's own application

The detailed yes or no on whether skylights fall under the regulations at all sits in our short answer on Building Regulations. This page picks up after that: once the job is in scope, what actually happens.

Why your roof's build era changes the paperwork

On most estates built around the town since the 1960s the roof is made of factory trussed rafters at regular centres. A roof window chosen to drop between two trusses leaves every truss whole, so the structural side of the notification is simple: the opening is framed with noggins and the trusses are untouched. Ask for anything wider and at least one truss has to be cut and the load carried elsewhere. That is designed trimming, normally backed by a calculation, and building control will expect to see how the load path works before the saw comes out. The trade-offs of that route are laid out in going bigger in a trussed roof.

Older village and town centre houses usually have cut rafters, sized and fixed by hand. Trimming a cut rafter is a familiar carpentry detail, but it still changes the structure, so it is still recorded. What changes in those streets is the planning side, which is often the longer conversation where a conservation area applies.

Popley, Oakridge, Winklebury and Brighton Hill were built largely as volume estates on trussed rafter roofs, while Old Basing, Sherborne St John and Overton keep conservation area cores with cut rafter roofs. Two houses a few miles apart can need quite different supporting information for the same size of skylight.

What the inspector is actually looking at

A building control officer does not approve the brand of window. They check that the finished work meets a handful of technical parts of the regulations. For a domestic rooflight these are the ones that come up.

Structure

The opening must not weaken the roof. Between the trusses that means proper trimmers and fixings; through them, it means a designed solution built as drawn.

Energy

The new glazing has to meet the thermal standard in force when it goes in, which is higher than the one an old dome or timber window was made to. The unit's declared performance is what gets recorded, and it is one reason a like for like swap is rarely identical to what came out.

Moisture and ventilation

The lining around the window and any insulation in the reveal should avoid cold spots where condensation forms, and a room that relies on the rooflight for fresh air needs a way to open it.

Fire and escape

In a converted loft, a roof window can be the planned escape route, which sets rules on its clear opening and its height above the floor. That is decided with the loft conversion's design, not on the day of fitting.

Building notice, full plans, or a private approver

There is more than one way to tell building control about the work, and the right one depends on how complicated the roof is.

The rule: for a straightforward replacement or a new roof window that sits between existing rafters or trusses, a building notice is normally the simpler route, because the work is inspected as it goes rather than approved from drawings. The exception: where trusses are cut or an opening is enlarged, a full plans application or a structural design lodged in advance gives everyone certainty before the roof is opened.

The local authority is not the only option. A registered building control approver, the private sector alternative, can take on the same role for domestic work. Either way the principle is the same: the body you notify is the one that inspects and signs the work off, so the notice should be in place before anything is cut.

Loft room with a new roof window between trusses and fresh plaster reveals
A new opening framed between two trusses, ready for building control to see before the lining goes on

How the notification runs on an Everlight installation

Where the work is notifiable we submit the notification ourselves, so the owner is not left filling in forms about a roof they have never seen from above. The order below is the order it happens in.

  1. Survey. We look at the roof from inside and out, record the build era, the truss or rafter spacing and the covering, and note whether the job is a replacement, a new opening or a wider one. The rooflight survey guide explains what else is measured.
  2. Specification. The unit is chosen to fit the structure, and its thermal rating is written into the quote so it can be quoted back to building control.
  3. Notice lodged. The notification goes in before work starts, with any structural design attached where trusses are involved.
  4. Inspection. If the officer wants to see the opening framed before it is lined, the fitting day is arranged so they can.
  5. Sign-off. Once the work is complete the notice is closed and the completion certificate is issued to you as the owner.

Infographic

Planning and Building Control: the questions in order

  1. Is the house listed?

    Yes: listed building consent is needed before any rooflight goes in.

    No: next question.

  2. Is it in a conservation area, or a flat or maisonette?

    Yes: check with the council. A conservation-style rooflight is often the expected choice.

    No: next question.

  3. Will it sit within permitted development limits?

    Usually yes when it projects no more than 150mm from the roof plane and stays below the highest part of the roof.

    If not: a householder planning application.

  4. Is the work notifiable under the Building Regulations?

    A new rooflight, or a replacement that changes the structure, is. We notify Building Control for you.

    Either way the glazing must meet current thermal standards.

A general guide to the order of questions, not advice on a particular house. We check your position at the survey.

The completion certificate, and why it matters later

The certificate is the only part of the job you will ever need to find in a drawer, so put it somewhere you will find it.

A completion certificate, or the scheme certificate where a replacement was self-certified, is the written evidence that the rooflight was installed to the regulations in force at the time. It sits with the house records, and it comes back into view when the house is sold: a buyer's solicitor will ask for it for any recent alteration to the roof or glazing. A missing certificate rarely stops a sale outright, but it can slow one down while indemnity or retrospective routes are discussed. If a sale is on the horizon, replacing tired rooflights before selling covers timing.

Keep the certificate with the window's product paperwork and the guarantee document. Between them they answer the three questions a buyer or surveyor will ask: what was fitted, when, and whether it was signed off.

Replacing like for like is still in scope

It is tempting to think that swapping an old unit for a new one of the same size, in the same hole, sits outside the rules. It does not. A replacement roof window is treated as new glazing, and it has to meet today's energy standard rather than the one the original was built to. The regulations also expect the replacement not to make the building worse in other respects, such as fire escape from a loft room.

That has a practical upside. A modern unit in a 1970s or 1980s opening will almost always keep more heat in than what came out, and the paperwork records that improvement. Where a larger or different unit is being considered at the same time, the like for like or upgrade guide works through the choice, and whether a skylight counts as a window explains the classification in a sentence.

Unconverted lofts, extensions and outbuildings

A rooflight in a loft used only for storage still changes the roof, so the structural side still applies even though the room is not habitable. Whether it is sensible to put one in at all, and what it does to the insulation line, is covered in the answer on unconverted lofts.

In a new kitchen extension the rooflight or lantern is part of the extension's own building control application, so it is recorded there rather than separately. On a detached garage or garden room the position depends on the building's size and whether it is heated, which the survey notes before anyone assumes it is exempt.

A flat roof over a single storey rear extension on a 1980s estate house is a common place for a new skylight to go in after the fact. There the roof joists, not trusses, carry the load, and the kerb or upstand is part of what gets recorded, because it forms the join between the new glazing and the roof covering. The notification describes the opening, the unit and how the covering is made good around it.

Daylight falling into a loft room
Figure 3 Daylight falling into a loft room

What stays with you as the owner

Responsibility for compliance rests with the owner as well as the builder, which is why it pays to know who is submitting what before a date is booked. Four questions settle it: is this job notifiable, who is lodging the notice, which body is it going to, and who will the certificate be addressed to. Clear answers to those, in writing, are worth more than any verbal reassurance on the doorstep.

Separately from the regulations, our work carries a 10-year workmanship guarantee. It is not insurance backed, and it covers how the rooflight was fitted rather than the manufacturer's product warranty, so you end up with three documents: the certificate, the product warranty and our guarantee. For the wider picture of fitting a rooflight or skylight on a Basingstoke roof, or the specifics of a pitched roof window, those pages go further. If you would like the paperwork question answered for your own house, arrange a survey and it will be part of the written quote.

Free roof survey

Tell us about your roof

  • Survey before any quote
  • No obligation
  • Plain-English advice

Say what you have in mind and where. We survey the roof before we quote, then tell you plainly what fits.

Prefer to talk? 01256 213206

Request my survey