Look down from an upstairs window at the back of a house built around Basingstoke in the 1970s or 1980s and there is a fair chance you will see one: a pale bubble of plastic sitting on a flat roof, over a kitchen extension, a garage, a utility room or the link between house and garage. When it was new it was clear or softly milky. Decades later it may be yellow, chalky, crazed with fine lines or gone brittle at the edge. This guide is about that plastic rooflight dome: how to judge whether it has had its day, what the frame and roof underneath it decide, and the choices for what goes back in.
The dome itself is the easy part. The questions worth asking are about the timber kerb it sits on and the flat roof around that kerb, because those decide whether the job is a straight swap or something slightly bigger.
What went onto flat roofs in that era
Flat roofs were a normal part of the house types built in the town's expansion years. The terraces and townhouses on estates such as Popley, Oakridge and Brighton Hill were built alongside flat-roofed garages, porches, rear extensions and linking sections, and later owners added more flat-roofed kitchens and garden rooms of their own. Where those spaces had no window wall, a moulded plastic dome was the standard way to get daylight in.
The domes of the period share a simple build. A shaped sheet of acrylic or polycarbonate has a flat flange around its edge, and that flange is screwed down onto a raised frame, the kerb, which lifts the dome above the roof surface. Some were a single skin of plastic; others had a second or third skin inside, trapping air between the layers. Some had a small opening vent, many were fixed. Inside, a plasterboard or timber shaft runs from the kerb down to the ceiling, so the dome becomes a bright square in the room below.
Acrylic and polycarbonate both age in sunlight. Acrylic tends to stay clear longer but is the more brittle of the two; polycarbonate is tougher against knocks but can yellow and go cloudy. Either way, a dome that has sat through several decades of summers is near the end of what the material can give.
Flat rooflight on an insulated upstand
- Double glazed rooflight, set to a slight fall so rain runs off the glass
- Upstand (kerb): a timber kerb with insulation on its outer face
- Membrane dressed up the upstand and over the top, sealed under the rooflight frame
- Waterproof membrane covering the roof, falling towards the gutter outlet
- Insulation laid over the deck, keeping the structure warm
- Roof deck on tapered firrings, which create the fall
- Joists, trimmed around the opening with trimmer joists
- Plasterboard reveal lining the opening, meeting the ceiling below
Reading the signs on your own dome
You can tell a lot from indoors and from an upstairs window, without climbing onto anything. The table sets out what to look for and what each sign usually points to.
| What you notice | What it usually means | Where it points |
|---|---|---|
| Yellow or brown tint | The plastic has broken down in sunlight and lets through less light | A new dome or glazed unit; the kerb gets checked at the same time |
| Fine crazing or a chalky surface | The outer skin is losing strength and will keep getting worse | Plan the replacement before a cold snap or a knock finds the weak spot |
| Cracks at the screw holes | The flange has gone brittle where it was fixed down | The dome cannot be refixed; the kerb top is inspected under it |
| Drips of water indoors on cold mornings | Condensation on a single-skin dome over a warm, damp room | A multi-skin dome or a glazed unit with better insulation |
| Stains on the shaft or ceiling | Could be condensation, or water getting past the kerb or the roof edge | A close look at the kerb and the flat roof covering at the survey |
| Soft or dark timber around the shaft | The kerb or the deck edge has been wet for some time | A new kerb, and possibly new deck boards around the opening |
If the only complaint is a tired, tinted dome, the choice is mostly about what you want next. If there are stains or soft timber, the answer depends on what is found under the flange. Our answer to when a rooflight should be replaced gives the short version of that judgement.
The kerb decides more than the dome
On roofs of this age the kerb was usually built on site from timber, boxed up from the deck, with the roof covering dressed up its sides and the dome screwed to its top. Later units often came with factory-made kerbs in plastic or glass-reinforced plastic, with insulation built in. The difference matters, because the kerb is the part that has spent decades under the edge of the covering.
A sound timber kerb that is the right size for a standard replacement dome can be reused. The old dome comes off, the top of the kerb is checked and cleaned, and the new dome goes down onto it. A kerb that is soft, split or out of square is taken out and replaced, which means lifting and remaking the roof covering around the opening. A kerb that is sound but an odd size can sometimes be adapted, or a dome can be ordered to suit it.
The rule: the new unit is never fixed to a kerb that has not been seen with the old dome off. The exception is when there is no choice to make: if the whole roof is being re-covered anyway, the old kerb comes out as part of that work and a new one goes in with the new covering.
Timber kerbs from this period are also short on insulation. That is part of why the edges of the shaft feel cold and why condensation forms at the base of the dome even when the plastic is multi-skin. A new insulated kerb deals with that at the same time.
The flat roof around it
A dome can only perform as well as the flat roof it sits in. Flat roofs from the 1970s and 1980s were usually finished in built-up felt or, on some, asphalt, laid over chipboard or timber boards on joists. Many have since been re-covered in newer felt systems, single-ply membranes or glass-reinforced plastic. Knowing roughly when yours was last covered helps plan the dome work.
- Recently re-covered. The dome is replaced on its own, and the covering is carefully cut and remade around the kerb only if the kerb has to change.
- Covering in fair order but ageing. The dome can be replaced now, with the kerb detail done so it can be picked up cleanly when the roof is re-covered later.
- Covering near the end of its life. Doing the dome and the roof together saves disturbing the same edge twice and lets the kerb be rebuilt properly from the deck up.
That third case has its own guide: replacing rooflights while the roof is being re-covered explains how the order of work runs and who does which part.

What can go back in
A replacement does not have to be another plastic dome. The opening in the roof is already there, which makes this one of the easier points in a house to change the kind of daylight a room gets. The options below are the ones that suit an existing flat-roof opening.
| Option | What it is | Kerb | Suits |
|---|---|---|---|
| New plastic dome, multi-skin | A modern double or triple skin dome in the same shape as the original | Existing kerb if sound and a standard size, otherwise new | Garages, utility rooms and anywhere a quick, simple swap is the aim |
| Flat glass rooflight | A sealed glazed unit in a slim frame, looking almost flush with the roof | Usually a new insulated kerb with the fall built in | Kitchens and living spaces where the view up matters |
| Opening or vented unit | A dome or glazed rooflight that opens by hand or electrically | Kerb sized to the opening unit | Kitchens and bathrooms that need fresh air as well as light |
| Roof lantern | A framed glazed structure standing up from the roof, pitched on each side | A new, larger kerb; the opening may be widened | Larger extensions and rooms that are to be opened up |
Which one is right depends on the room as much as the roof. A garage or store may be well served by a new multi-skin dome. A kitchen used every day often gains more from glass. The trade-offs between keeping the same type and moving up are set out in like for like or upgrade.
From plastic dome to flat glass
Changing a dome for a flat glass skylight is the natural upgrade on these older extensions, and it changes the room more than you might expect: the view up is clear sky rather than a milky bubble, and a sealed glazed unit keeps the room warmer than the old plastic. It does need a kerb built for it, because a flat glass unit relies on a fall to shed rain, and that fall is usually built into the upstand rather than the roof. Our flat roof rooflight installation page covers the glazing, kerb and finish choices in detail.
Sizes are worth a quick word. Old domes were made to a range of kerb sizes that do not always line up with current glazed units. Where they differ, the new kerb is built to the new unit, and the opening in the deck is trimmed to match, which on a flat roof of this age is usually straightforward joinery between the joists.
The opening is already in the roof; the choice is what kind of daylight comes through it next.
Condensation, warmth and the room below
A single-skin plastic dome over a kitchen or bathroom is a cold surface above a room full of warm, damp air, so water forms on the inside and runs down or drips. That is a property of the dome, not a sign that it is failing, and it is one of the best reasons to replace it. Our answer on why skylights get condensation goes through the causes and what helps.
Multi-skin domes and sealed glazed units both cut the problem back, and an insulated kerb stops the cold running down the shaft. Ventilation in the room still matters. If your worry is heat loss rather than drips, do skylights make a room cold? answers that directly.
Inside, the old shaft is usually kept and refreshed: new plasterboard where it has stained or softened, a clean edge at the ceiling, and a decorated finish. If the kerb changes size, the shaft is rebuilt to line up with it so the light falls straight into the room.
Building Control and planning, briefly
Replacing a rooflight can bring Building Regulations into play, mainly on insulation, and a change to the opening or the structure brings in more. On these jobs we look after the Building Control notification where the work is notifiable, so you have the paperwork when you sell. The general position is in do skylights need Building Regulations approval?
Planning is rarely the issue for a like-for-like replacement on a rear flat roof. A roof lantern that stands higher than the old dome, a house in a conservation area, or a front-facing roof can change that, and those cases are checked with the council before anything is ordered.
How the swap is done
Most dome replacements follow the same order, whatever goes back in. The survey settles which version of this list applies to your roof.
- Survey. We look at the dome, the kerb, the covering around it and the shaft below, and measure the opening. You get a written quote that says what is being reused and what is new.
- Protect the room. Floors and worktops under the shaft are covered before anything is unscrewed.
- Old dome off. The fixings are removed and the dome lifted clear, which shows the true condition of the kerb top.
- Kerb. A sound kerb is prepared for the new unit; a poor one comes out and a new insulated kerb is fixed to the deck.
- Weathering. The roof covering is dressed up the kerb and sealed to suit the covering on your roof.
- New unit. The dome, glazed rooflight or lantern is fixed down to the manufacturer's method.
- Inside. The shaft is made good and the room is cleaned before we leave.
A straight dome swap on a sound kerb is short work. A new kerb, a glazed unit or a lantern takes longer, and a re-cover alongside longer again. For a sense of timing, see how long it takes to replace a skylight.
Choosing what comes next
An old plastic dome has done its job if it has kept a flat-roofed room light for decades. The replacement should suit how that room is used now: a store or garage may want nothing more than a clear new dome, while a kitchen or family room may be the place to move to glass or a lantern. The roof covering and the kerb set the practical limits, and both are seen properly only with the old dome off.
If you are weighing this up across a whole house, including pitched roof windows from the same decade, our guide to old roof windows by era puts the flat-roof domes alongside everything else that went into 1970s and 1980s roofs. For the wider picture of how we approach rooflight replacement around Basingstoke, the homepage sets out the survey, the fit and our 10-year workmanship guarantee, which covers our work and is not insurance backed.
When you would like someone to look at the dome, the kerb and the roof together, arrange a roof survey and you will get a written answer on what can stay, what should change and what goes back in. You can also start from the Everlight homepage if you want to see the other ways we bring daylight into older estate houses.