Question answered · Rooflights and skylights

Do skylights make a room cold?

The short answer

A modern, well fitted rooflight should not make a room noticeably colder. Cold rooms under a skylight almost always trace back to something else: an old single-skin plastic dome or tired double glazing, a gap in the insulation around the opening, or cold air sliding down from glass that sits well below room temperature. Fix the unit and the lining, and the chill usually goes with them.

Daylight falling into a loft room

Glass will always lose more heat than a well insulated ceiling, so a skylight is a trade: daylight in exchange for a small area of roof that holds warmth less well. Whether you notice that trade depends on what was fitted and how. The page on skylight installation and replacement around Basingstoke sets out how we specify a unit for the roof it goes into; this answer deals with the narrower worry of a cold room and where the cold really comes from.

Where the chill actually comes from

People describe a cold skylight in different ways, and each description points at a different cause. Separating them matters, because the remedy for one does nothing for another.

What you feel under a skylight, and what is usually behind it
What you noticeLikely causeWhere to look
A cold spot directly under the glassCool air falling off a glass surface that runs colder than the roomThe glazing itself: its age, its number of panes, whether the seal has gone
A draught around the frameAir moving through gaps between the frame, the lining and the roofThe reveal inside and the junction between the frame and the ceiling
The whole room never warms upMissing or thin insulation around the shaft or kerbThe loft side of the lightwell, or the upstand on a flat roof
Wet glass on winter morningsWarm, damp room air meeting a cold inner paneVentilation in the room and the performance of the glass

That last row overlaps with a separate question, and our answer on why skylights get condensation covers it in full.

Sizing a roof window to the truss bays On the left, a section through a pitched roof built from Fink trussed rafters, with W-shaped webs joined by nail plates, tiles on battens, and a roof window set in the slope. On the right, the same slope seen square-on: trusses at even 600mm centres with a narrow roof window sitting in the bay between two of them, so no truss is cut. A wider window outline, drawn dashed, crosses a truss and would need designed trimming. Section600mm centresSeen square-on12345678

Sizing a roof window to the truss bays

  1. Fink trussed rafter, factory made and designed to work as one whole frame
  2. W-shaped webs, joined at every node by pressed metal nail plates
  3. Tile covering on battens over the underlay
  4. Roof window set in the slope, fitted between trusses so the frame is untouched
  5. Narrow roof window sitting in the bay between two trusses
  6. Trusses at even 600mm centres along the roof
  7. No truss cut: the trusses either side of the window stay whole
  8. A wider window crosses a truss, so the cut needs designed trimming from an engineer or the truss maker

Old units are the usual culprit

Around Basingstoke, a cold room under a rooflight is very often a room under an original unit. The 1970s and 1980s estates were finished with single-skin or twin-skin plastic domes on flat roofs over kitchens, garages and porches, and with early timber roof windows in pitched roofs. Neither was built to today's thermal standards, and decades of sun break down plastic and seals alike.

A misted double glazed pane is a useful clue. The mist means the seal between the panes has failed, and once it has, the gap no longer insulates as intended, so the inner pane runs colder than it should. Our guide to old roof windows by era helps you date what is in your roof, and the guide on replacing plastic domes on flat roofs covers the flat roof version of the same story.

A skylight that makes the room cold is usually telling you its age, not its type.

The opening matters as much as the glass

A high performing unit set into a badly finished opening still leaves a cold room. Heat escapes wherever insulation stops short: behind the plasterboard lining of the lightwell in a pitched roof, around the timber kerb of a flat roof rooflight, or at the point where the new frame meets the old ceiling. Air leaks there too, and a thin line of moving cold air is what people feel as a draught.

The rule: insulation has to run continuously from the roof into the reveal and up to the frame, with no bare timber or open gap between them. The exception is where a vapour control layer or ventilation path is specified by the maker, which is fitted to their detail rather than packed with extra material.

This is why replacing only the glass sometimes disappoints. If the lining and the insulation around the old frame were poor, the new unit inherits the weakness. When we replace a rooflight, the reveal comes off where needed so the junction can be insulated and sealed properly before it is finished again.

What a modern specification changes

Current roof windows and flat roof rooflights use sealed double or triple glazing with low emissivity coatings, insulated frames and, on flat roofs, insulated upstands. The inner pane stays much closer to room temperature, so there is less cold air falling off it and less surface for condensation to form on. The specifics of glazing options and thermal ratings belong on our energy efficient rooflights page, which compares them properly.

A replacement unit is also held to Building Regulations thermal requirements, so the new one has to meet a standard the original never had to. That is one reason why, on houses where the old unit has failed, the question of whether replacing old skylights is worth it tends to answer itself.

Rooms where it matters most

A little heat loss overhead is barely noticed in a hallway or on a landing, where people pass through. It matters more where people sit still or sleep. A bedroom in a loft conversion or a chalet bungalow sits right under the roof, with the rooflight close to the bed, so a cold pane there is felt more than one over a staircase. Our answer on whether a skylight is a good idea in a bedroom looks at blinds, ventilation and placement for that room in particular.

Blackout and thermal blinds help on winter nights by trapping a layer of air against the glass, and they are worth considering for bedrooms and nurseries. They are an addition to a good unit, not a cure for a failed one.

How to check yours before calling anyone

  1. Look at the glass. Mist between the panes, crazed or yellowed plastic, or a single sheet with no second layer all point to the unit.
  2. Feel the frame edges. On a cold, windy day, run the back of your hand around the reveal. Moving air means a gap in the finish.
  3. Look from the loft if you can. In a pitched roof, check whether insulation reaches right up to the sides of the lightwell or stops short of it.
  4. Note when it happens. Chill only on clear nights suggests the glazing; chill in wind suggests air leakage around the frame.

Those notes help at a survey, where we check the unit, the lining and the roof around it before writing a quote. If your rooflight is making a room colder than it should, arrange a survey and we will tell you which part is letting the warmth out.

Free roof survey

Tell us about your roof

  • Survey before any quote
  • No obligation
  • Plain-English advice

Say what you have in mind and where. We survey the roof before we quote, then tell you plainly what fits.

Prefer to talk? 01256 213206