GuideRoof lanterns

Condensation, ventilation and Part F under a roof lantern

Why a roof lantern mists up, which parts of the glazing, kerb and roof decide it, and how Part F ventilation applies to the room below.

A roof lantern over an open-plan kitchen extension
A roof lantern over an open-plan kitchen extension

On a cold morning a new roof lantern can look as though it is weeping. Beads gather along the glazing bars, a few drops fall onto the worktop, and the natural fear is that something has gone wrong with the roof. It usually has not. What you are seeing is water that was already in the air of the room, meeting the coldest surface it can find. This guide explains where that moisture comes from, which parts of a lantern and its kerb decide how cold the inside faces get, and how Approved Document F (Part F, the ventilation part of the Building Regulations) shapes the way a room under a lantern should breathe.

It is written for owners of single storey rear extensions around Basingstoke, where a lantern over a kitchen diner or a family room is the usual reason for putting glass in a flat roof. If you are still deciding on the lantern itself, the roof lantern installation service page covers the whole job; this page stays on the one question of damp air and cold glass.

Why glass overhead collects water first

Warm air holds more water vapour than cool air. When room air touches a surface below its dew point, the vapour turns back into liquid on that surface. In a room with a lantern, the glass and the frame are the parts nearest the outside temperature, and they sit at the top of the room where the warmest, wettest air rises and collects. A window in a wall has the same physics, but the air at the top of a room is where steam from a pan or a shower ends up, so glazing in the ceiling meets that air first.

There is a second reason. A lantern faces the open sky. On a clear night the outer pane loses heat by radiation to the sky much faster than a wall window facing a fence or a neighbouring house, so the inner pane runs a little colder too. That is why a lantern can show condensation on a still, starry night when the wall windows in the same room stay clear.

None of this means the unit has failed. Moisture on the room side of the glass is a sign of room humidity against surface temperature. Moisture trapped between the panes is a different matter entirely, and is covered further down.

How a roof lantern sits on a flat roof A roof lantern drawn in elevation above a flat roof, with the roof cut away in section below. The glass panels are held by glazing bars running up to a central ridge, with hip bars at each end and a perimeter frame along the eaves. The frame sits on an insulated kerb, the flat roof covering is dressed up the kerb, and a plastered reveal lines the well that opens into the room below. Outside Room below 1 2 3 4 5 6 7 8

How a roof lantern sits on a flat roof

  1. Ridge, where the glazing bars meet at the top
  2. Hip bar, closing each sloped end of the lantern
  3. Glazing bar, holding the edges of the glass
  4. Glass panel, sealed double or triple glazed units
  5. Eaves or perimeter frame, which the whole lantern stands on
  6. Insulated kerb (upstand), raising the lantern clear of the roof
  7. Flat roof covering, dressed up the kerb and under the frame
  8. Plastered reveal, lining the lantern well into the room below

Where the moisture in the room comes from

A kitchen extension is one of the wettest rooms in a house. Cooking, a kettle, a dishwasher opened mid-cycle, washing dried on an airer, and simply several people sitting round a table all add water to the air. Open plan layouts, now the norm when a back wall is knocked through, let that air drift across the whole ground floor and up into the lantern well.

A brand new extension adds its own load. Screed, plaster and blockwork are laid wet and give up that water for months as they dry. Condensation on a lantern in the first winter after a build is often construction moisture leaving the structure, and it tends to ease as the building dries out, provided the room is ventilated while it does.

A misted lantern is usually telling you about the air in the room, not the glass in the roof.

The cold spots: bars, kerb and the edge of the glass

Condensation does not form evenly. It appears first on whichever inside surface is coldest, and on a lantern that is rarely the middle of the pane. The table below sets out where to look and what governs each spot.

Where condensation shows first under a roof lantern
LocationWhy it runs coldWhat reduces it
Glazing bars and ridgeMetal conducts heat outward if the inner and outer faces are not separatedThermally broken aluminium bars or insulated capping systems
Edge of each glass unitThe spacer bar between the panes carries heat past the insulating gapWarm edge spacers rather than plain metal spacers
Inside face of the kerbA timber or masonry upstand left without insulation bridges straight to outsideInsulation wrapped up the kerb and lined with plasterboard
Where the reveal meets the ceilingA gap in the insulation line around the trimmed openingInsulation carried tight to the trimmers with no voids
Centre of the paneOnly in very humid rooms, as the glass itself is usually the warmest partLower humidity and better air movement past the glass

The pattern matters because it points to the cause. Droplets strung along the bars point to the frame; a damp line on the plaster just inside the kerb points to the upstand; a whole pane misted from edge to edge points to room humidity. The way the kerb is built and insulated is set out in the guide to kerb height and falls, so it is not repeated here.

What the glazing and frame contribute

Two choices made at order stage decide how warm the inside of the lantern stays. The first is the glass. Double or triple glazed sealed units with a low emissivity coating and gas fill keep the inner pane closer to room temperature, and that alone lifts the surface above the dew point on all but the wettest days. The short answer on specifications is in what glass goes into a roof lantern.

The second is the frame. Aluminium is strong and slim, but it conducts heat readily, so a good aluminium lantern separates the inner and outer parts of each bar with a polyamide or resin thermal break. uPVC systems use chambered profiles, often reinforced, and the capping arrangement matters as much as the material. The trade offs are covered in aluminium or uPVC glazing bars. Whichever you choose, ask whether the bars are thermally broken right through to the ridge and the hips, because a cold ridge casting drips onto the floor below.

Older lanterns glazed with twinwall or multiwall polycarbonate run far colder than modern glass units and often drip for that reason alone. If you have one of these, swapping a polycarbonate lantern for glass is usually the more useful conversation than fans or dehumidifiers.

Condensation between the panes is a different problem

If the moisture sits inside the sealed unit, between the two sheets of glass, no amount of wiping or ventilating will clear it. That means the edge seal of the unit has broken down and damp air has got into the cavity. It is the unit that needs replacing, not the room that needs airing. On a lantern the glass units can often be replaced individually without taking the frame off the roof, which is the same principle behind replacing a misted or failed rooflight elsewhere in a house.

The rule: water on the room side of the glass is a humidity and ventilation question, and water between the panes is a failed seal. The exception is an old single skin or polycarbonate lantern, where both problems can look alike because the inner face is cold enough to drip even in a well aired room.

What Part F asks of an extension with a lantern

Approved Document F sets out how a dwelling should be ventilated. For a new habitable room it looks at three things. Extract ventilation removes moisture at source in wet rooms such as kitchens and bathrooms, usually through a cooker hood ducted outside or an extract fan. Background ventilation provides a small, steady supply of fresh air, traditionally through trickle vents in window frames. Purge ventilation lets you clear the room quickly, for example after burnt toast or a crowded dinner, and is normally met by openable windows or doors of adequate size.

A roof lantern touches all three. A fixed lantern adds glass but no ventilation, so the rest of the extension has to provide it. An opening lantern, or one with a hinged vent, can contribute to purge ventilation, and some systems include trickle vents in the frame for background ventilation. Whether a particular design meets the guidance is a matter for the Building Control body looking at the whole extension, not a feature any single product can promise on its own.

Part F also matters when an existing lantern or rooflight is replaced. The expectation is that the room should end up no less well ventilated than before, so if the old unit had a vent or a trickle vent, the replacement should keep an equivalent. Whether that work is notifiable is summarised in do roof lanterns need Building Regulations approval; where it is, Everlight looks after the notification as part of the installation.

Opening vents and how they help

Warm, wet air rises, and a lantern is the highest point of the room. An opening vent in the lantern lets that air escape exactly where it gathers, which is why a vented lantern over a kitchen can stay clearer than a fixed one of the same size. It also gives a cross draught with the patio or bifold doors on a summer day. The options for hinged vents and full opening sections are set out in can a roof lantern be made to open.

Vents high in a flat roof are out of reach, so they are generally worked by a motor. A rain sensor closes the vent when the first drops land, which means the lantern can be left open while you are out. The same controls are used on electric opening skylights in flat roofs, and the electric and opening rooflight installation page explains how those are wired and switched.

Kitchen diner under a roof lantern with one glazing panel hinged open above the dining table
An opening vent at the top of the lantern lets warm, damp air leave where it collects

A vent is not a substitute for a cooker hood. Steam released at the hob should be captured there and ducted outside, so the lantern only has to deal with what escapes.

The roof around the lantern: warm roof or cold roof

Condensation can also form out of sight, inside the flat roof itself. How the roof around the lantern is built decides where that risk sits.

In a warm roof the insulation sits above the deck, with a vapour control layer beneath it, so the timber stays on the warm side. When a lantern opening is cut, the vapour control layer has to be turned up and sealed to the kerb, or moist room air can work into the insulation at the edge of the opening.

In a cold roof the insulation sits between or below the joists, and the void above it is ventilated along its length so that any vapour reaching it can escape. A new opening and its trimmers can block that airflow in the bays either side. The joists are cut short, the trimmers run across them, and the ventilation path from one end of the roof to the other is interrupted. The installer has to keep air moving through those bays or the timber above the insulation can stay damp. The structural side of trimming is explained in joist direction and trimming.

On estate houses around Basingstoke, the single storey extensions added to 1970s and 1980s semis and detached homes vary widely in how the flat roof was built, and some have been re-covered since. The survey checks which type of roof is there before the opening is set out.

How the survey checks for condensation risk

Condensation is easier to design out than to live with, so it is part of the survey rather than an afterthought. On the visit we look at the room, the roof and the way the house is used, then specify the lantern and its kerb to suit.

  1. The room. What happens below the lantern: a hob, a sink, a dining table, a sofa. Where the cooker hood vents and whether it ducts outside.
  2. The existing ventilation. Openable windows and doors, trickle vents, extract fans and whether any of these will be removed or boxed in by the new work.
  3. The roof build up. Warm roof or cold roof, the direction of the joists, where the vapour control layer sits and how the roof void is ventilated.
  4. The kerb. Whether a new insulated upstand is needed or an existing one can be lined and insulated properly on the inside.
  5. The specification. Glass units, thermally broken bars, warm edge spacers, and whether an opening vent is worth adding over this particular room.
  6. The paperwork. Whether the work is notifiable and what the Building Control body will want to see about ventilation.

Living with a lantern through the first winter

Even a well specified lantern can show a little condensation in a new extension while it dries out. A few habits make a real difference. Run the cooker hood whenever the hob is on and for a while afterwards. Leave trickle vents open rather than closing them against draughts. Open the lantern vent, or a window, for a short burst after cooking or when drying washing indoors. Keep the heating steady instead of letting the room chill overnight and then heating it fast in the morning, because cold surfaces followed by a sudden rush of warm, wet air is when glazing mists hardest.

Blinds fitted inside the lantern can trap a pocket of still air against the glass. If you plan to fit them, a gap for air to move or a habit of opening them during the day helps the glass stay clear. The same applies to any skylight or rooflight in a cold, humid room, not only a lantern.

Worth knowing: occasional mist on the outside of modern, highly insulated glass on a cold, clear morning is a sign the glass is keeping heat in, not letting it out. It clears as the sun reaches the roof.

A roof lantern over a kitchen island
Figure 2 A roof lantern over a kitchen island

Getting it right before the lantern goes in

Condensation under a roof lantern comes down to a few decisions: warm glass and bars, an insulated kerb with the vapour line sealed, a roof void that can still breathe, and a room that gets rid of steam at source and has a way to clear the air quickly. Each is simple on its own, and together they decide whether a lantern stays clear or drips on the table on winter mornings.

For the wider picture of fitting daylight to the house you have, the Basingstoke rooflight and skylight home page sets out how Everlight approaches each roof by its build era. When you are ready for someone to look at your extension, arrange a survey of the roof and room and the ventilation question is answered on the same visit as the size, the kerb and the glass. Every lantern Everlight fits comes with a 10-year workmanship guarantee, which is not insurance backed, and you can read more about the full job on the roof lantern installation page.

Free roof survey

Tell us about your roof

  • Survey before any quote
  • No obligation
  • Plain-English advice

Say what you have in mind and where. We survey the roof before we quote, then tell you plainly what fits.

Prefer to talk? 01256 213206

Request my survey