Question answered · Rooflights and skylights

Do skylights need Building Regulations approval?

The short answer

Yes, in most cases. A brand new skylight changes the roof structure and the insulated envelope, so it falls under Building Regulations and must be notified to Building Control. A like-for-like swap of an existing rooflight is a controlled fitting too: the new unit has to meet current thermal standards and be certified, either through a competent person scheme or a Building Control notification. Planning permission is a separate question.

Daylight falling into a loft room

People tend to ask this once the idea of a skylight has turned into a real plan, usually just after a quote or a loft drawing lands on the kitchen table. The rules are national, so they apply the same way in Chineham as in Overton, but what they ask of the roof depends on how it was built. Our rooflight and skylight installation page for Basingstoke sets out the whole job; this answer covers only the regulations side.

It helps to keep two systems apart. Planning deals with how the house looks from outside. Building Regulations deal with whether the work is safe, sound and energy efficient. A rooflight can need nothing from the first and still need sign-off under the second.

Which parts of the regulations touch a rooflight

There is no single skylight rule. Several of the Approved Documents meet at the opening, and which ones matter depends on whether you are adding an opening or replacing a unit in one that already exists.

Building Regulations that can apply to a skylight in England
Approved DocumentWhat it asks of the rooflightWhen it comes into play
Part A, structureThe roof must still carry its loads once the opening is formedAny new opening, and above all where a rafter or truss is trimmed
Part L, energyThe glazed unit must meet the current thermal standard for a controlled fittingNew rooflights and replacement units alike
Part C, moistureThe opening must keep weather out and not create damp at the junctionWherever the roof covering is opened and made good
Part F, ventilationTrickle vents or opening sashes where the room needs background ventilationHabitable rooms, often loft bedrooms
Part B, fireA window big enough and low enough to serve as an escape route where one is requiredLoft conversions creating habitable rooms

On a simple swap in a bathroom, only Part L and the weathering really bite. On a new opening in a loft bedroom, all five can.

Sizing a roof window to the truss bays On the left, a section through a pitched roof built from Fink trussed rafters, with W-shaped webs joined by nail plates, tiles on battens, and a roof window set in the slope. On the right, the same slope seen square-on: trusses at even 600mm centres with a narrow roof window sitting in the bay between two of them, so no truss is cut. A wider window outline, drawn dashed, crosses a truss and would need designed trimming. Section600mm centresSeen square-on12345678

Sizing a roof window to the truss bays

  1. Fink trussed rafter, factory made and designed to work as one whole frame
  2. W-shaped webs, joined at every node by pressed metal nail plates
  3. Tile covering on battens over the underlay
  4. Roof window set in the slope, fitted between trusses so the frame is untouched
  5. Narrow roof window sitting in the bay between two trusses
  6. Trusses at even 600mm centres along the roof
  7. No truss cut: the trusses either side of the window stay whole
  8. A wider window crosses a truss, so the cut needs designed trimming from an engineer or the truss maker

Adding a new skylight: why it is notifiable

Cutting a fresh opening in a roof is a material alteration. The structure is changed, even if only the battens and covering are opened between two rafters, and the thermal line of the roof is broken and rebuilt around the new frame. That is why a new rooflight goes to Building Control before the work, with an inspection or completion sign-off afterwards.

How much the structural side matters turns on the roof itself. On a cut rafter roof in an older village house, trimming a rafter is ordinary carpentry that the inspector will want to see done properly. On the trussed estates of Popley, Brighton Hill or Hatch Warren, a truss is an engineered part: a window that sits between trusses leaves the structure untouched, while anything wider needs a written trimming design before a saw goes near it.

The rule: a new opening is always a Building Regulations matter. The exception is about paperwork, not safety: where a registered competent person carries out work that their scheme covers, they self-certify it instead of notifying the council, and the homeowner gets a certificate either way.

Loft bedroom ceiling with a new roof window set between trusses and freshly lined reveals
A new opening in a loft room goes to Building Control before any roof timber is touched

Replacing an existing rooflight

Changing a tired unit for a new one in the same opening sounds like it should sit outside the regulations, and structurally it often does. The glazing is still a controlled fitting, though, so the replacement has to meet the thermal standard in force now, not the one in force when the house was built. A 1970s plastic dome or an early single-glazed roof window comes out, and something considerably warmer has to go back in.

Going up a size changes the picture again, because the opening then grows into new rafter or truss bays and the structural side returns. Our guide to going bigger when a roof window is replaced covers that step on trussed roofs.

The guide to Building Control notification for rooflights owns the full process: when the notice goes in, what the inspector looks at, and what paperwork you should hold at the end.

Competent person schemes and the FENSA question

Homeowners are often told that a window needs a FENSA certificate, and ask whether a roof window is the same. Competent person schemes let registered installers self-certify certain work, such as replacement windows, and the scheme then issues the certificate. They are one route to compliance, not a separate requirement. Where an installer is not self-certifying through a scheme, the same work is notified to Building Control, which inspects it and issues a completion certificate.

At Everlight the notification to Building Control is sorted by us as part of the job, so the certificate for your rooflight arrives without you filling in a form. Whether a roof window counts as a window for these purposes is answered directly in is a skylight classed as a window?

Where planning fits alongside

Building Regulations approval says nothing about planning, and the reverse is also true. On most houses a rooflight falls within permitted development if it stays close to the plane of the roof and below the ridge, but listed buildings, flats and conservation areas with extra controls need their own check. That side is set out in do I need planning permission for a skylight?

Two separate questions, two separate answers: one about looks, one about how the roof performs.

What goes wrong when it is skipped

  1. At sale. A buyer's conveyancer asks for the completion certificate or scheme certificate for recent roof work, and a missing one slows the sale.
  2. Retrospectively. Regularising work after the event can mean opening up linings so an inspector can see the trimming and insulation.
  3. In the roof. An opening cut without a design in a trussed roof can load the neighbouring trusses in ways they were never meant to take.

That is also why fitting one yourself deserves a careful look first, covered in can I replace a skylight myself?

Infographic

Planning and Building Control: the questions in order

  1. Is the house listed?

    Yes: listed building consent is needed before any rooflight goes in.

    No: next question.

  2. Is it in a conservation area, or a flat or maisonette?

    Yes: check with the council. A conservation-style rooflight is often the expected choice.

    No: next question.

  3. Will it sit within permitted development limits?

    Usually yes when it projects no more than 150mm from the roof plane and stays below the highest part of the roof.

    If not: a householder planning application.

  4. Is the work notifiable under the Building Regulations?

    A new rooflight, or a replacement that changes the structure, is. We notify Building Control for you.

    Either way the glazing must meet current thermal standards.

A general guide to the order of questions, not advice on a particular house. We check your position at the survey.

Getting it right on your roof

We survey the roof before we quote, and the survey is where the regulations become specific: whether the timbers are trusses or cut rafters, whether the window sits between them, whether the room will need an escape window or trickle vents. The written quote then lists what Building Control will need. Our workmanship guarantee runs for 10 years and is not insurance backed. When you are ready to find out which rules your roof actually triggers, arrange a survey visit.