None of these checks decides anything on its own. They give the survey a head start, and they help you describe the problem clearly when you ring. The survey itself, and the choice between a new pane and a whole new unit, belong to our misted and failed rooflight replacement service, which begins on the real roof rather than from a guess over the phone.
Think of what follows as a slow walk round an ageing skylight with a torch, a tape measure and your phone camera. Nothing here needs a ladder above the first rung of a stepladder indoors.
Start with the glass, and wipe it first
Before anything else, clean the room face of the glazing with a dry cloth on a cold morning. If the haze comes away and then returns on the surface, that is condensation from the room, a ventilation matter rather than a sign the unit has gone. If the cloth changes nothing because the fog, droplets or white bloom sit inside the double glazing, the edge seal of the sealed unit has let moist air in. Our guide to telling condensation from a failed unit walks through the tests in more detail.
| What you see | Where it sits | What to note for the survey |
|---|---|---|
| Mist that wipes away | On the room face | When it appears (mornings, after showers, while cooking) and how the room is ventilated |
| Fog or droplets you cannot reach | Between the panes | Whether it comes and goes with the weather or stays all day |
| Milky streaks or white residue | Between the panes | A close photo in daylight; residue usually means the seal went some time ago |
| A crack or a star in the glass | Outer or inner pane | Which pane, if you can tell, and whether water shows below it |
For a quick way to weigh up what you have found, our answer on how to know if a rooflight has failed sets out the signs in order of weight.
How a sealed rooflight unit works and fails
- Outer and inner glass panes, with the outer pane facing the weather
- Low-emissivity coating on one inner face, reflecting heat back into the room
- Warm-edge spacer bar holding the panes apart, filled with desiccant to soak up trace moisture
- Primary seal against each pane, backed by the secondary seal around the edge
- Dry sealed cavity, the insulating layer between the panes
- Broken edge seal: moist air gets in and the desiccant becomes saturated
- Mist and droplets trapped between the panes; they cannot be wiped off and the sealed unit needs replacing
- Inset: condensation on the room-side face of the glass is a ventilation or humidity issue, not a failed unit
Open it, close it, and look at the seals
If the rooflight opens, work the handle or the control bar through its full travel. Note whether the sash binds, drops, or needs a shove to shut, and whether the catch pulls it tight. On a centre pivot roof window, feel whether it holds its position part way open. Then look along the rubber gaskets where the sash meets the frame: cracking, flattening, gaps at the corners and pieces that have pulled loose all matter, because a unit can have clear glass and still let weather past a tired seal.
On a fixed flat rooflight or a dome, there is no sash to test, so look instead at the frame corners and at the joint between the glazing and its kerb. Dark lines, lifting trims or discoloured plastic are all worth a photo.
Check the ceiling and lining around it
Walk round the reveal (the lined box between the ceiling and the frame) with a torch held flat to the surface, so any ripple or stain throws a shadow. Brown tide marks, bubbling paint, soft plaster or black mould on the lining each point somewhere different: some come from the glazing, some from the flashing outside, some from warm room air meeting a cold frame. Our guide to water staining around an old rooflight explains how the pattern of a stain hints at its source.
Worth knowing: a dry stain can be old history from a flashing that was dealt with years ago. The exception is a mark that grows or darkens after heavy rain, which is the one to mention first when you book.
Find the label and measure the opening
A replacement goes most smoothly when the existing unit can be identified. Many branded roof windows carry a small data plate, often on the frame at the top of the opening or on the inside of the sash when it is swung open, with a type and size code on it. Older plastic domes and site-made flat rooflights often carry nothing at all, which is fine; the measurements then do the work.
- Look for a plate or sticker. Check the top of the frame and the sash edge, and photograph any code you find exactly as printed.
- Measure the visible glass. Width and height of the pane you can see, taken from the room.
- Measure the lining opening. The inside of the plastered reveal, side to side and top to bottom, so the surveyor knows how much room there is.
- Note the roof it sits in. A pitched roof with tiles or slates, or a flat roof with felt, membrane or a GRP finish.
- Note the house. Its rough build era, and whether you know it has trussed rafters or an older cut roof.
Those five notes largely decide whether a like for like unit drops into the same opening. The answer on whether the new rooflight will be the same size covers what happens when an older size is no longer made. For branded roof windows, the separate question of whether just the glass can be changed in a VELUX depends partly on that data plate.
Look at the outside, from the ground
From the garden, a bedroom window or across the road, use your phone's zoom to look at the outside of the unit. Note the covering around it, whether the metal flashing sits flat and neat, whether moss or debris has gathered at the top edge, and whether a dome has gone cloudy or brittle looking. On a flat roof over an extension, you may be able to see the upstand from an upstairs window.
The rule: photograph it from the ground and leave the roof alone. Fragile domes, old felt and wet tiles are no place to stand. Safe access is part of the survey, and the surveyor brings it.
Infographic
How a rooflight job runs, from survey to guarantee
Roof survey
We look at the structure, the covering and the room below before anything is priced.
Specification
A size, type and position that fits your roof, and whether the work is notifiable.
Paperwork
Building Control notified where the work needs it, and planning checked where it applies.
Installation
Opening formed, frame fixed, flashed or dressed in, then lined and finished inside.
Sign-off and guarantee
Completion paperwork where needed and a 10-year workmanship guarantee.
What to have ready when you book
Gather the photos, the label code, your measurements and a short note of what worries you: the fog, a stain, a stiff sash, or simply age. Add anything you know about the house, such as whether the loft was converted and roughly when, and what sits below the rooflight inside, because a landing over a stairwell asks for different access than a bedroom ceiling.
With that, the visit can go straight to the questions only a surveyor can answer on the roof itself: the state of the kerb or the timbers round the opening, the flashing detail, and whether the replacement is a new pane, a new rooflight in the same opening, or something better suited to the room. We quote only after that look. When your notes are together, arrange your survey here, or see how we approach skylight replacement around Basingstoke as a whole.