An estate house loft was never drawn as a room. It was drawn as a roof: a row of factory trusses at even spacing, webs criss-crossing the void, a shallow pitch chosen because it was quick to tile. Turning that space into a bedroom or a study means changing the structure first, and the VELUX windows are part of that change rather than something added at the end. This guide follows a loft conversion in a typical 1960s to 1990s estate house around Basingstoke, from the first sketch to the finished reveal, and shows where the roof windows belong in each decision.
The houses in question are the ones that fill Popley, Oakridge, Brighton Hill, Lychpit, Hatch Warren and Chineham: semis, terraces and link-detached homes built by volume housebuilders to repeated house types. Their lofts share a family likeness, and so do the choices a conversion forces on them.
Why the trusses change everything in a conversion
In a cut rafter roof, a converter can often work around the timbers already there. A trussed roof gives no such option. The W-shaped webs that fill the loft are what hold each truss rigid, so an open room cannot exist until they are taken out, and they can only come out once a structural engineer has designed what replaces them. That replacement is usually a new floor structure spanning between load-bearing walls, new or doubled rafters on the slopes, and one or more steel or timber beams carrying the load the webs used to share.
For the roof windows this is good news. While the trusses stand, a VELUX window installation on an estate roof is shaped by the 600mm gap between them, which is why our guide to VELUX sizes that fit between 600mm trusses exists. Once a conversion is being designed, the rafter layout on each slope is being drawn afresh. The engineer can set rafter positions, trimmers and headers around the openings you want, provided they know about them before the drawings are finished.
Sizing a roof window to the truss bays
- Fink trussed rafter, factory made and designed to work as one whole frame
- W-shaped webs, joined at every node by pressed metal nail plates
- Tile covering on battens over the underlay
- Roof window set in the slope, fitted between trusses so the frame is untouched
- Narrow roof window sitting in the bay between two trusses
- Trusses at even 600mm centres along the roof
- No truss cut: the trusses either side of the window stay whole
- A wider window crosses a truss, so the cut needs designed trimming from an engineer or the truss maker
Rooflight-only, dormer or hip-to-gable: where the windows end up
The type of conversion decides which slopes carry roof windows and how much work they do. On a shallow estate pitch, a conversion that keeps the roof shape and relies on windows alone only works where there is enough height under the ridge; otherwise a dormer creates the standing room and the windows light what remains.
| Conversion type | Where the VELUX windows go | What decides their size |
|---|---|---|
| Roof shape kept, windows only | Front and rear slopes, carrying all the daylight and ventilation for the room | Head height under the slope, the new rafter layout and the escape rules |
| Rear dormer | Usually the front slope, over the stair or the shallow side of the room | What is left of the slope below the ridge, and the planning position on the street elevation |
| Hip-to-gable (semis and end terraces) | The remaining slopes, often paired with a dormer to the rear | How the new gable wall and ridge beam are framed |
| Room in the roof over a garage or link | One slope, often the only source of light | The low pitch of the extension roof and its tile or slate type |
None of these is better in the abstract. The right one follows from the ridge height, the street elevation and what the room is for.

Put the windows on the engineer's drawing, not after it
The single step that saves the most trouble on an estate conversion is agreeing the window positions and widths early, then handing them to whoever is designing the structure.
The rule: every roof window opening is drawn on the structural design, with its trimming, before any truss is cut. The exception: a window that fits between two new rafters at their designed spacing needs no extra trimming, but it still belongs on the drawing so the rafters are placed to suit it.
Decisions that feed into that drawing include how many windows, whether any sit side by side or one above the other, whether one is a balcony type, and whether the room layout will put a bed, a desk or a bath under a particular slope. If a window is moved after the steels are ordered, the engineer has to revisit the trimming, and on site that tends to mean delay. Fixing the layout first keeps the structure and the daylight working to the same plan.
Headroom, pitch and how high the glass sits
Estate roofs are often shallow, and that shapes a loft room in two ways. First, the usable floor area with proper standing height shrinks towards the middle of the room, so the windows need to light the part people actually stand in. Second, a low pitch limits which models and flashings suit the slope; our answer on how shallow a roof a VELUX can go in sets out that limit.
On a shallow slope a window of a given height reaches less far up the room, so a taller unit may be needed to bring the top of the glass high enough for a view out rather than just sky. The height of the bottom edge matters too: set low, it gives a seated view from a desk or bed; set higher, it frees wall space below for storage in the eaves. Whether the sash should hinge at the top or pivot in the middle depends on what sits under it, and the guide to top hung versus centre pivot works through that choice.
A loft room is lit from the slope, so the window has to be placed for the person standing in the room, not for the roof seen from the garden.
Widths and pairs across the new rafters
Where a conversion keeps rafters at the original 600mm spacing, the narrow widths that slot between them keep trimming to a minimum, and two or three of those in a row can give as much glass as one wide unit. Where the engineer sets out the slope differently, a wider single window becomes practical because its trimmers are designed in from the start. The choice then comes down to the look you want inside and how the room is furnished, rather than what the roof will tolerate.
A side-by-side pair shares a combination flashing, and a window stacked above another gives height on a long slope. Both arrangements need their spacing agreed with the structure, which is one more reason to settle the layout before the drawings close.
Think about the room from the doorway, too. On a terrace or semi the stair usually arrives on the front side of the loft, so a window over the stairwell brings light down to the landing below, while the rear slope, or the dormer face, lights the bedroom itself. Matching unit heights across the room keeps the lines of the slope calm, and using one model family means blinds, handles and controls all behave the same way.
Getting out of a loft room in a fire
A loft conversion adds a storey to the house, and the Building Regulations then look closely at how people get out. The main route is normally a protected stair down through the house, built with fire-resisting doors and linings. A roof window can also be specified as an escape window, which brings its own requirements for the size of the clear opening and the height of its bottom edge above the floor. Our answer on whether a VELUX can be an escape window covers what qualifies.
The escape strategy for the whole conversion is set by the Building Control route the project follows, so the window choice should be confirmed against it rather than assumed. If a balcony unit is being considered for the rear slope, the guide to VELUX CABRIO balcony windows explains how it opens and what it needs from the roof.
Planning on an estate: what to check first
Roof windows on a house often fall within permitted development, subject to limits on how far they project from the slope and on side-facing glazing. Estates add a wrinkle: some were approved with conditions that removed permitted development rights, and some are covered by an Article 4 direction. The planning history of the estate and of your own house is worth checking with the local council before the design is fixed. The answer on planning for VELUX windows explains the general position, and a dormer brings its own separate tests.
Around Basingstoke, the council that holds your planning history depends on the town: Basingstoke and Deane for Popley, Chineham, Hatch Warren and Tadley; Hart for Hook, Fleet and Yateley; Rushmoor for Farnborough. Restrictive covenants in the title deeds are a separate matter from planning, so check both.
Newer estate houses raise one more question: a housebuilder warranty may still be running. Check its terms before any structural work, and read our answer on fitting a VELUX into a new build roof for what that means in practice.
When the windows go in during the build
On a conversion the roof windows are fitted at a set point in the sequence, once the new structure is in and before the room is closed up.
- Survey and layout. We look at the roof covering, the pitch and the loft, then agree window positions and sizes with you and the conversion designer.
- Structure. The engineer's design is built: new floor, beams, rafters and trimmers around each opening, with the trusses taken out only as the design allows.
- Openings formed. Tiles or slates are stripped locally and the membrane is cut back to the trimmed opening.
- Windows and flashings. Frames are fixed, the underfelt collar and flashing kit are fitted to suit the tile or slate, and the covering is made good around them.
- Insulation and lining. The insulation collar is fitted, the slope is insulated to the conversion's specification, and a splayed lining is set out for the plasterers.
- Finish. Plaster, decoration and blinds follow; the sash is checked for smooth opening once the room is complete.
How the reveal is formed inside, and whether the frame is set lower into the roof for a flush look, is covered in the guide to recessed installation and linings.
Living in the room: heat, blackout and a loft bathroom
A loft room sits right under the tiles, and roof windows face the sky rather than the street. That makes them excellent for daylight and more exposed to summer sun than a wall window. External awnings or shutters stop heat before it reaches the glass, and blackout blinds suit a bedroom where the room is used on light summer mornings. The guide to VELUX blinds and shutters sets out the options by room.
Where the conversion adds a shower room under the lower slope, a skylight may be its only natural light. That calls for the right frame finish and glazing for a humid room, and our answer on a VELUX over a shower or bath explains what to specify. A rooflight that opens gives the bathroom purge ventilation alongside its extractor fan.
Pricing the windows and booking the survey
Because the windows are drawn into the conversion, their cost depends on the number and size of units, the flashing for your tiles or slates, any blinds or electric operation, and how their fitting fits around the rest of the build. We look at the roof before putting a figure on paper, and the written quote reflects what the survey finds.
Where the windows form part of a larger conversion, they sit within that project's Building Regulations application; where we fit them on their own, we look after the notification. Our workmanship on the fitting is guaranteed for ten years, and that guarantee is not insurance backed. If your loft is still full of trusses and you are weighing up what is possible, ask us to survey the roof and bring the conversion drawings if you have them. For the wider picture of fitting a rooflight or skylight in a Basingstoke home, start at our homepage, and the full VELUX service page covers every model we fit.