What is the difference between VELUX GGL and GGU?

The short answer

Only the frame material. Both are VELUX centre pivot roof windows, opened by the same bar along the top of the sash, made in the same size codes and fitted with the same flashing kits. The last letter is the finish: L means a timber frame in pine, U means a white polyurethane coating moulded over a timber core. That coating shrugs off steam, so GGU suits bathrooms and kitchens while GGL suits drier rooms.

A centre-pivot roof window tilted open in a bedroom

So the choice is about the room below the glass, not about the roof above it. Everything to do with the opening, the trusses and the weatherproofing is identical, which is why our VELUX window installation survey settles size and position first and leaves the finish until we know which room the window serves. This answer covers what the two letters change, where each one earns its place, and how to read them on a window that is already in.

Reading the three letters

A VELUX type code is built letter by letter. The first G marks a roof window. The second letter gives the opening action: G for centre pivot, P for top hung. The third gives the frame finish: L for wood, U for white polyurethane. Put together, GGL and GGU are twins in every respect except that last character, and GPL and GPU are the top hung pair in the same two finishes. The size code and version digits that follow on the data plate are decoded in what the code on a VELUX window means.

GGL against GGU, point by point
PointGGLGGU
Opening actionCentre pivot, bar at the topCentre pivot, bar at the top
Frame surfacePine, lacquered or painted whiteWhite polyurethane moulded round a timber core
Room it suitsBedrooms, loft rooms, landings, studiesBathrooms, shower rooms, kitchens, utility rooms
Looking after itTimber finish renewed from time to timeWiped clean; no finish to renew
Size codes and flashingStandard range and kitsThe same range and kits
Sizing a roof window to the truss bays On the left, a section through a pitched roof built from Fink trussed rafters, with W-shaped webs joined by nail plates, tiles on battens, and a roof window set in the slope. On the right, the same slope seen square-on: trusses at even 600mm centres with a narrow roof window sitting in the bay between two of them, so no truss is cut. A wider window outline, drawn dashed, crosses a truss and would need designed trimming. Section600mm centresSeen square-on12345678

Sizing a roof window to the truss bays

  1. Fink trussed rafter, factory made and designed to work as one whole frame
  2. W-shaped webs, joined at every node by pressed metal nail plates
  3. Tile covering on battens over the underlay
  4. Roof window set in the slope, fitted between trusses so the frame is untouched
  5. Narrow roof window sitting in the bay between two trusses
  6. Trusses at even 600mm centres along the roof
  7. No truss cut: the trusses either side of the window stay whole
  8. A wider window crosses a truss, so the cut needs designed trimming from an engineer or the truss maker

Why the finish matters in a wet room

A roof window in a bathroom lives in a cloud of warm, damp air that rises straight to the highest cold surface, which is often the glass and the frame round it. Bare or lightly finished timber in that spot takes up moisture over the years, and once the lacquer wears the wood can mark and darken. The polyurethane skin on a GGU gives the moisture nothing to soak into, so a wipe after a steamy morning is all it asks for. For a skylight above a bath, a shower tray or a hob, that is the whole argument for the U.

Position matters as much as finish over a shower, because the reach to the control bar and any splash on the sash both come into it. Is a VELUX suitable over a shower or bath? deals with that directly.

Where the timber version is the better pick

In a dry room the pine frame has nothing to fear, and the warmer tone of wood against a plastered reveal is a matter of taste. A loft bedroom in a 1970s Brighton Hill semi, a study in a Chineham dormer or a landing rooflight in a Hatch Warren townhouse all sit comfortably with GGL. Painted white pine gives a clean look close to the polyurethane without giving up the timber. Where a room might change use later, say a loft room that could gain an en suite, weigh that up now: swapping a frame finish afterwards means a new window.

The rule: pick GGU wherever steam gathers, and pick on looks everywhere else. The exception: a kitchen with a strong extractor and a window well away from the cooker can take either, so the survey looks at where the vapour actually goes.

Changing one for the other

Because the two share outer frame sizes and flashings, a worn GGL over a bathroom can be swapped for a GGU of the same size code without enlarging the hole in the roof. The same holds the other way round. The trusses stay exactly as they are and the tiles or slates round the opening are only lifted as far as the new flashing needs. How a like-for-like exchange runs on an older window, and when the linings are worth changing too, is laid out in upgrading an old VELUX to a current model.

If you are specifying from scratch, the finish choice sits alongside the opening action. A centre pivot suits a window above head height or over furniture; a top hung sash suits a low window you want to lean out of. The guide to top hung and centre pivot owns that comparison, and it applies equally to both finishes.

White VELUX roof window set into a sloping bathroom ceiling above a bath
A white finished centre pivot window over a bath in a converted estate house loft

What neither letter tells you

The finish code says nothing about glazing, blinds or motors. The glass unit, the version digits and any INTEGRA electric operation are separate choices, and a GGU can carry the same glazing upgrade as a GGL. Nor does either letter change the fit in the roof. On a trussed estate roof at 600mm centres, the width decides whether the window sits between two trusses or needs a designed opening, and the size tables in the standard VELUX window sizes apply to both frames identically.

Mixing the two in one loft

A loft conversion can put a bedroom and an en suite under the same roof slope, and there is no need to pick one finish for both. A GGL over the bed and a GGU over the basin can sit side by side, because the outer frame, the grey aluminium cladding and the flashing are the same on each. From the garden or the street the pair reads as a matched set; only the inside tells them apart, where the pine and the white polyurethane each suit their own room.

On the trussed roofs of Basingstoke's 1970s and 1980s estates, where a converted loft gains both a sleeping space and a shower room, the finish is best settled window by window at the survey rather than ordered as one choice for the whole job.

Getting it right on your roof

We check the room, the roof covering and the truss or rafter spacing before we put a figure on paper, so the finish is chosen with the rest of the specification rather than as an afterthought. A new roof window of either kind is notifiable to Building Control, and we look after that paperwork. The fitting carries a 10-year workmanship guarantee, which is not insurance backed. Want a second opinion on a window that is already showing its age over a bath? Arrange a survey of your roof and we will read the plate, look at the room and tell you which letter belongs there.

Free roof survey

Tell us about your roof

  • Survey before any quote
  • No obligation
  • Plain-English advice

Say what you have in mind and where. We survey the roof before we quote, then tell you plainly what fits.

Prefer to talk? 01256 213206

Request my survey