Why does condensation form on a VELUX?

The short answer

Condensation forms on a VELUX when warm, damp air from the room touches glass that is colder than the air's dew point. A roof window faces the open sky at an angle, so its inner pane loses heat faster than a wall window and turns cold sooner. Water on the room side is a moisture and airflow matter; water trapped between the panes means the sealed unit has failed and wants replacing.

A centre-pivot roof window tilted open in a bedroom

Where the droplets sit tells you almost everything, so that is where this answer starts. If you are still deciding on a window rather than living with one, our VELUX window installation page covers choosing and fitting from the roof up; what follows is about the glass you already have over your head.

Which side of the glass is wet?

Run a dry finger across the pane. Three different things can be going on, and each has its own cause.

Where the water sits on a roof window, and what it points to
Where the water isWhat is happeningWhat to do first
Room side of the inner paneIndoor moisture meeting cold glass, often worst on winter mornings or after a showerOpen the ventilation flap, run extraction, check the lining is insulated
Outside face of the outer paneDew on a well insulated unit, because little heat escapes to warm the outer glassNothing; it clears as the sun comes onto the roof
Between the two panesThe edge seal of the glazing unit has let moist air into the cavityPlan a new glazing unit or a whole new window
How a sealed rooflight unit works and fails Two close-up edge sections of a double-glazed rooflight unit. On the left a healthy unit: two panes held apart by a warm-edge spacer bar filled with desiccant, primary and secondary seals, a dry sealed cavity and a low-emissivity coating on one inner face. On the right the edge seal has broken, moist air has got in and mist sits between the panes; a small inset shows condensation on the room-side face of the glass instead, which is a ventilation issue, not a failed unit. Healthy unit Failed seal 1234 5678

How a sealed rooflight unit works and fails

  1. Outer and inner glass panes, with the outer pane facing the weather
  2. Low-emissivity coating on one inner face, reflecting heat back into the room
  3. Warm-edge spacer bar holding the panes apart, filled with desiccant to soak up trace moisture
  4. Primary seal against each pane, backed by the secondary seal around the edge
  5. Dry sealed cavity, the insulating layer between the panes
  6. Broken edge seal: moist air gets in and the desiccant becomes saturated
  7. Mist and droplets trapped between the panes; they cannot be wiped off and the sealed unit needs replacing
  8. Inset: condensation on the room-side face of the glass is a ventilation or humidity issue, not a failed unit

Why a sloping window runs colder than an upright one

A vertical window in a wall sees part sky and part ground, buildings and trees, all of which give back some warmth. A skylight in a pitched roof looks mostly at open sky, and on a clear night the glass radiates heat straight up into it. The shallower the pitch, the more sky it faces. That is why the same room can have a dry wall window and a wet rooflight on the same morning.

Warm air also rises. In a loft room or on a landing, the damp air from the whole house tends to gather at the top of the ceiling, which is exactly where the roof window sits. Put those two facts together and condensation on the inner pane is a natural result of physics, not proof that something is wrong with the window.

Where the moisture comes from

Every household puts water into the air: breathing, cooking, drying washing indoors, baths and showers. A few situations push it higher than usual:

  • A new loft conversion. Fresh plaster and screed give off water for months as they dry, so the first winter is often the wettest the glass will ever be.
  • Bathrooms and en suites. Steam rises straight to the window. Our answer on whether a VELUX suits a shower or bath covers the glazing and positioning for that room.
  • Bedrooms with the door shut. Two people sleeping in a small eaves room raise the humidity overnight, and the glass shows it by morning.
  • Estate houses made airtight over time. On a 1970s or 1980s house with replacement windows, cavity fill and draught-proofed doors, less air leaks away than when it was built, so moisture stays inside unless something removes it.

The quick checks that cut it down

  1. Open the ventilation flap. Most VELUX windows have a vent bar along the top of the sash. Left open, it lets a trickle of air through with the window shut and is the simplest control you have.
  2. Raise any blind at night now and then. A blackout blind traps a pocket of air against the glass that cools right down. Leaving a gap at the top lets room air keep the pane warmer. An outside awning or shutter shades the glass without that trapped layer.
  3. Keep heat under the window. A radiator below a roof window warms the air rising over the glass. A cold room below a skylight will always struggle.
  4. Use the extractor. Run it during and after bathing or cooking so the steam leaves before it reaches the roof.
  5. Wipe the frame on bad mornings. Standing water on a timber frame marks the finish; a quick wipe keeps it looking right.

When the lining is the real cause

If condensation keeps running down the reveals as well as the glass, look at the lining around the window. The plasterboard sides of the opening should be insulated behind and taped to the window frame so warm air cannot reach the cold roof timbers. Where an older fitting left a gap or skipped the insulation, the reveal becomes a cold strip and water collects on it. Getting that detail right at install time is covered in our guide to recessed installation and linings; a well fitted lining is part of the reason a newer roof window stays drier than the one it replaced.

Worth knowing: dew on the outside of the pane on a cold, clear morning is a good sign, not a bad one. It means the unit is holding heat in. The exception is water between the panes, which never clears on its own.

Misting between the panes

A glazing unit is two or three sheets of glass sealed around the edge, with dry gas in the gap. Over years the edge seal can let go, damp air gets in, and the inside of the cavity mists over in a way no cloth can reach. On an older timber roof window from a 1980s or 1990s estate build, that is simply the unit reaching the end of its life.

The fix is a new unit or a new window in the same opening. Current VELUX sizes are made to replace older ones without cutting the roof again, so the trusses stay as they are; our answer on the standard VELUX window sizes shows how the codes line up. If the frame is sound and only the glazing is tired, the misted rooflight replacement service covers that route. Better glazing for a cold room, and what each pane type changes, is set out in VELUX glazing options.

Can a new window stop it completely?

No window can promise zero condensation, because the cause is partly the air in the room. What a current unit does is keep the inner pane noticeably warmer than old double glazing, and with a properly insulated lining and a working vent flap, water on the glass becomes an occasional winter morning event rather than a daily one. For the fuller trade-offs of a roof window, including this one, read what the disadvantages of VELUX windows are.

If your window is wet every day, or misted inside the unit, the useful next step is someone looking at the glass, the flap and the lining together. Arrange a roof survey and you will get a written answer on what is causing it before any quote.