This comes up most with loft conversions, flats and stairwells, where someone has read that the top of a staircase should be able to vent smoke and wonders whether the electric rooflight they already want will cover it. The rooflight itself belongs to our electric and opening rooflight installation work; the fire duty belongs to the design of the building, and the two need keeping apart until someone with the authority to decide has said which one applies.
What makes a smoke vent different
A smoke vent, often called an AOV (automatic opening vent), exists to let hot smoke out of an escape route so people can get down the stairs and firefighters can get up them. That job sets demands a comfort rooflight is never asked to meet. The whole unit, frame and opener together, is tested as a natural smoke and heat exhaust ventilator under BS EN 12101-2, which checks that it opens fully in a set time, works under snow and wind load, and survives heat. The power supply and control panel have their own standard. The opening has to give a stated aerodynamic free area, which is not the same as the size of the glass or how far the sash lifts.
| Point of difference | Comfort electric rooflight | Certified smoke vent |
|---|---|---|
| Purpose | Daylight and fresh air when you choose | Clearing smoke from an escape route in a fire |
| Trigger | Wall switch, remote, app or rain sensor | Smoke detector or a break-glass override point, through a control panel |
| Power | Mains or a solar panel and small battery | Mains with a monitored standby battery in the control panel |
| Testing | Normal product standards for a window | Tested as a complete smoke ventilator to BS EN 12101-2 |
| Opening | Whatever suits airflow and weather | Sized to the free area the fire strategy calls for |
How rooflights and roof windows open
- Centre-pivot sash, turns so the lower edge tips out and the top swings in, handy for cleaning from inside
- Pivot point, the hinge line across the middle of the sash
- Top-hung sash, swings outward clear of the opening for a wider view
- Top hinge, where the sash is hung from the head of the frame
- Fixed rooflight, glazing sealed to the upstand with no moving parts
- Electric opening rooflight, the glazed lid lifts from one edge for ventilation
- Motorised chain actuator, pushes the lid open and draws it closed
- Rain sensor, closes the rooflight automatically when it starts to rain
When a house actually needs one
For a single family house, Approved Document B generally deals with a loft conversion by protecting the stair: fire-resisting enclosure, fire doors onto it and linked smoke alarms, so the route down stays usable. A smoke vent at the stairwell head is not the usual answer in that setting, though an escape window or another arrangement may be. In blocks of flats the picture changes. Common stairs and corridors serving several homes often do call for smoke ventilation, and a vent at the head of a common stair is a familiar sight there.
The rule: the fire safety design decides whether a vent is needed, not the window choice. The exception is any case where Building Control, a fire engineer or a freeholder has already written a smoke vent into the plan; then only a certified product, installed and commissioned as a system, meets it.
Houses split into flats, and flats above shops in the older centres around Basingstoke, are where this question gets serious. If your home shares a stair with anyone else, ask the building owner or managing agent before you plan anything overhead, because a vent in a common part is usually their system, not yours.
Why a comfort rooflight cannot simply be upgraded
Fitting a quicker motor, or linking a domestic rooflight to a smoke alarm through a smart hub, does not produce a smoke vent. Certification covers the tested combination of frame, sash, opener and seals, so changing one part leaves an untested assembly. The standby supply is the other gap: a smoke ventilation panel watches its own battery and wiring and reports a fault, whereas a normal electric opener simply stops when power is lost. Our answer on what happens to an electric rooflight in a power cut explains that ordinary behaviour, which is perfectly fine for comfort and wrong for life safety.
The motor is not the weak point either. The rooflight actuator on a comfort unit is built for gentle daily use, while a smoke vent opener must drive the sash fully open against snow or wind within its rated time. Same idea, a different specification entirely.
Smoke venting, purge ventilation and fresh air
Three duties get muddled here. Background ventilation is the steady trickle of fresh air a room needs. Purge ventilation is the ability to clear a room quickly of cooking fumes, paint smell or summer heat, and an opening rooflight can play a part in it; our answer on whether an opening rooflight counts as purge ventilation covers that. Smoke ventilation is the fire duty above, and nothing about meeting the first two gets you any closer to the third.
So the everyday benefit of an electric skylight still stands. Opened high on a landing, it lets warm air out of the top of the house, which is where it gathers, and the guide on electric opening rooflights and ventilating a room sets out how to get the most from that. Just keep the words straight on any drawing: "opening rooflight for ventilation" and "smoke vent" are not interchangeable.
Getting the right answer for your stair
- Find out whether a vent is required. On a loft conversion or a change to a stair, the Building Control body or your designer confirms the fire approach before products are chosen.
- If it is, specify a certified system. A dedicated smoke ventilation rooflight, its control panel, detectors and override point are designed together, and the supplier's documents show the certification and free area.
- If it is not, choose the comfort rooflight on its own merits. Size, opener, controls and where the switch sits; the guide to wiring and controls for an electric rooflight is the place to plan that.
- Keep the paperwork. A smoke vent needs commissioning records and regular testing by whoever is responsible for the building; a comfort unit needs only its manual and our guarantee record.
Where the job is a comfort rooflight over a stair or landing, we look at the roof first, measure the opening against the timbers and quote in writing afterwards. The electrical side is notified along with the rest of the work, and the fitting carries a 10-year workmanship guarantee, not insurance backed. For the broader picture of rooflights in homes of every era across the borough, the Everlight home page is the starting point. When you know which duty your staircase needs, arrange a survey of the roof and we will match the rooflight to it.




