GuideElectric opening rooflights

Wiring, power and where the controls go for an electric rooflight

Where the power for an electric rooflight comes from, how the cable is hidden, what the electrical rules say and where the switch or keypad should go.

An electric rooflight open above a kitchen
An electric rooflight open above a kitchen

An electric rooflight is two jobs sharing one opening. The roof side is carpentry and weathering; the room side is a cable, a supply point and a control that somebody will reach for every warm evening for years. When those two jobs are planned separately, the result is a cable stapled across a finished ceiling or a keypad stuck beside a door nobody uses. Planned together, the wiring disappears and the control sits exactly where your hand expects it.

This guide covers the room side: where the power comes from, how the cable travels from the frame to the wall, what the electrical rules say about it, and how to decide where the switch or keypad belongs in each kind of room. The roof side, including sizes and the fit between trusses, is covered on our electric and opening rooflight installation page.

What actually needs power on an opening rooflight

Strip the unit down and there are only a few powered parts. There is the motor, usually a chain or spindle actuator fixed to the frame, which pushes the sash open and pulls it closed. There is a small control unit, either built into the frame or mounted nearby, which turns a mains feed into the low-voltage supply the motor runs on and listens for commands. And on most models there is a rain sensor on the outer frame that tells the control unit to close the sash when water lands on it. Some units add an integrated blind with its own motor on the same control.

That is the whole list. A room light or a socket draws far more, so the supply question is never about capacity. It is about getting a single, protected feed to the right point on the frame, tidily, and giving the homeowner a control that makes sense in the room. If you want to know what the actuator itself is doing, the short explainer what is a rooflight actuator? covers it.

How rooflights and roof windows open Four side sections. A centre-pivot roof window whose sash turns about its middle, and a top-hung roof window whose sash swings out from a hinge at the top, both in a pitched roof. Below them a fixed flat rooflight that does not open, and an electric flat rooflight lifted on a chain actuator with a rain sensor on the frame. Centre-pivot Top-hung Fixed Electric 1234 5678

How rooflights and roof windows open

  1. Centre-pivot sash, turns so the lower edge tips out and the top swings in, handy for cleaning from inside
  2. Pivot point, the hinge line across the middle of the sash
  3. Top-hung sash, swings outward clear of the opening for a wider view
  4. Top hinge, where the sash is hung from the head of the frame
  5. Fixed rooflight, glazing sealed to the upstand with no moving parts
  6. Electric opening rooflight, the glazed lid lifts from one edge for ventilation
  7. Motorised chain actuator, pushes the lid open and draws it closed
  8. Rain sensor, closes the rooflight automatically when it starts to rain

Three ways to power it

Before any cable is planned, the first decision is whether the skylight needs a hard-wired feed at all. There are three routes, and each changes what happens inside the room.

Power options for an electric rooflight and what each asks of the room
Power sourceWhat is wired in the roomWhere the control can goBest suited to
Mains, hard-wiredA cable from a fused connection unit to the frame, hidden in the lining and ceilingWired switch, wireless keypad or handset, app through a gatewayNew builds, loft conversions and extensions where the ceiling is still open
Solar with batteryNothing; a small panel on the frame charges a battery in the unitWireless keypad or handset anywhere within rangeFinished rooms where no one wants to open the ceiling
Mains through a retrofit kitA motor kit added to a suitable existing sash, with a feed run to itAs for mains, depending on the kitAn existing manual window of a compatible make and model

The choice between solar and mains has its own guide, solar-powered opening rooflights compared with mains. For this page, the useful rule is that solar trades a cable for a battery, and mains trades a battery for a cable. Everything below assumes a mains feed, because that is where the planning happens.

Where the supply is taken from

A mains-powered opening rooflight is fed from a fused connection unit, often called a fused spur. It gives the window its own fuse and a switch to isolate it, so the motor can be made dead for servicing without turning off a whole floor of the house. The spur is usually taken from a nearby circuit. On a loft conversion that is often the new circuit put in for the room; on a kitchen extension it may be a circuit already serving that part of the house.

Where that spur sits matters more than people expect. It needs to be somewhere an adult can reach to isolate the window, but it does not need to be on show. A landing wall, the side of a cupboard in the eaves or the wall just inside a loft door all work. What does not work is a spur hidden behind a fitted wardrobe, because the day it needs switching off, the wardrobe has to come out.

The rule: the feed to the window is protected and can be isolated at a point you can reach. The exception: a solar unit has no feed at all, so there is nothing to isolate; its battery and panel are dealt with at the frame.

How the cable travels from frame to wall

The cable leaves the control unit at the frame, usually from the top or one side, and has to reach the spur without being seen or damaged. The usual route is down behind the reveal lining, into the void above the ceiling or behind the sloping plasterboard, and along to a wall where it can drop to the spur or switch. In a flat roof extension it runs through the roof void between the joists to the nearest wall.

On the trussed roofs found across most Basingstoke estates, from the 1970s streets of Oakridge and Brighton Hill to the newer homes in Chineham and Hatch Warren, one point is non-negotiable. Truss members are not notched or drilled to take a cable, and nothing is fixed through the metal nail plates at the joints. The cable is clipped alongside a member or run in the bay between two trusses. This is the same principle that governs the opening itself: the trusses were designed as a set, and a notch for a cable weakens them just as surely as a notch for a window. The roof side of that story is on the roof window installation page.

Loft room with a sloping ceiling, an opening roof window and a small wall keypad beside the door
The keypad sits by the door so the window can be worked on the way in, with the cable hidden in the lining

Cable that ends up buried in thick loft insulation runs warmer than cable in open air, so the electrician chooses the route and the cable size with that in mind, and keeps the run clear of downlights and their heat. The route is also kept away from where anyone is likely to screw a shelf or a curtain pole into the reveal later.

Wiring in the right order

Most untidy electric rooflights come from doing things in the wrong sequence. If the plasterboard is already up and decorated when someone asks where the cable goes, the answer is chasing, surface trunking or a solar unit. If the route is agreed while the ceiling is open, the cable simply vanishes. The sequence on a loft conversion or extension looks like this.

  1. Agree the control position first. Decide where the switch or keypad goes and where the spur sits before the window is even ordered, because that fixes the cable route.
  2. Fit the window and its lining. The frame goes in, the flashing is fitted and the reveal lining is framed, leaving a clear path for the cable out of the control unit.
  3. First fix the cable. While the ceiling and sloping walls are still open, the cable is run from the frame to the spur point and clipped in the bay between trusses or joists.
  4. Board, plaster and decorate. The room is finished with the cable already hidden behind it.
  5. Second fix and connect. The spur and any wired switch are fitted, the window is connected, and the electrician tests and certifies the circuit work.
  6. Pair the controls and test the sensor. The keypad or handset is paired, the rain sensor is checked to close the sash, and you are shown how the manual override works.

On a finished room the order is shorter but the idea is the same: agree the control position and cable route before anything is cut, and choose solar if the route would mean opening a good ceiling.

What the electrical rules say

Connecting a rooflight to the mains is electrical work in a dwelling, which falls under Part P of the Building Regulations in England. Whether a particular job is notifiable depends on what is done: a new circuit is notifiable, while adding a spur to an existing circuit usually is not unless it sits in a special location such as a bathroom. The answer page is fitting an electric rooflight notifiable under Part P? sets out the distinction.

Either way, the connection is made and tested by a qualified electrician, who issues the right certificate for the work. For the plain answer to who does what, see does an electric rooflight need an electrician? The roof opening is a separate matter: installing the window alters the roof and its insulation, and we notify Building Control for that side of the job so there is one record of it.

Plan the cable while the ceiling is open, and the only sign of the wiring is a keypad by the door.

Where the control belongs, room by room

Where to put the control is a question about habit, not electrics. The right spot is where you already stand when you think about fresh air: the door as you walk in, the bedside, the kitchen worktop. A few rooms have their own logic.

Loft bedroom

A window high in a sloping ceiling is out of reach by design, so the control has to come to the person. A wired switch by the door handles the arrival, and a handset or a second wireless keypad by the bed handles the night. The loft bedroom has its own guide, an electric roof window for a loft bedroom out of reach, which covers blinds and night ventilation in more detail.

Top of a stairwell

A rooflight over the stairs is often the best vent in the house, pulling warm air up and out. The control belongs on the landing at the top, and sometimes a second at the bottom of the flight, so it can be opened on the way up and closed on the way down. The guide on opening rooflights at the top of a stairwell explains the stack effect behind it.

Kitchen extension

In a single-storey extension the rooflight is usually over the cooking or dining space. A keypad near the garden doors or at the end of the worktop is where most people reach, and it should be clear of the hob and the sink splash zone. The cable here runs through the flat roof void, so the route is fixed while the roof deck is still open.

Bathroom

Bathrooms bring zones. A wired switch has to sit outside the zones close to the bath or shower, and any spur is placed outside the room or well clear of them. A wireless handset kept by the door avoids the question for daily use. Whether an opening unit suits a bathroom at all is answered on is an opening rooflight good for a bathroom?

Wired switch, wireless keypad or app

Once the feed reaches the frame, the control can take several forms, and they can be combined. The difference is in what each needs from the walls.

Control types for an electric skylight and what each needs
ControlWhat it needsGood for
Wired wall switchA cable from the switch position to the control unit, run at first fixA fixed point by the door that never needs batteries
Wireless wall keypadA small battery and a clear signal path to the windowAdding a second control point later without new cable
Handheld remoteA battery and a place to live, such as a bedside drawerBedrooms and sitting rooms where you want control from a chair
App or smart home gatewayA gateway on the home network paired to the windowSchedules, closing the window when you are away, grouping several windows

Wireless keypads have made the control position far more forgiving, because a second point can be added without a new cable run. They still need a signal path, so a keypad behind a steel beam or several walls away may be unreliable. App control is a layer on top of the physical controls, not a replacement for them; the guide on app and smart home control of opening rooflights covers gateways and voice assistants.

Rain sensors, power cuts and the manual override

The rain sensor is wired as part of the unit, not by the homeowner, and needs power to act. That is why the feed matters beyond convenience: a window that is open when the supply drops cannot close itself on the sensor. What happens next depends on the make, and the answer page what happens to an electric rooflight in a power cut? goes through it. Most units have a way to close the sash by hand, explained on does an electric rooflight have a manual override?

Two practical points follow for the wiring. The spur should not share a circuit with anything likely to trip it regularly, such as an outdoor socket, and the sensor on the outer frame must be left clear of anything fitted later, like a satellite dish bracket or a vent terminal. The full detail on sensor behaviour is in rain sensors and automatic closing on opening rooflights.

Adding power to a rooflight you already have

If you have a manual roof window and want it motorised, the first question is whether the make and model accept a motor kit. Some do, and the kit bolts to the existing sash. Others do not, and the change means replacing the window. If the kit fits, the wiring question is the same as for a new unit: can a cable reach it without opening a finished ceiling? If the answer is no, a solar kit is often the tidier route, because it needs no cable at all.

The same logic applies where a fixed rooflight is being swapped for an opening one. The roof opening may stay the same, but the room now needs a feed that was never planned. Knowing where the nearest circuit runs and where the ceiling can be opened without damage is part of the survey, alongside the roof itself.

An opening rooflight above a hallway
Figure 2 An opening rooflight above a hallway

Getting the wiring planned on your survey

An electric rooflight is only as good as the control you use to open it. When we survey the roof before quoting, we also look at the room below: where you walk in, where you sit, where the nearest circuit runs, and whether the ceiling is open or finished. That is enough to say whether a wired feed, a solar unit or a mix of both makes more sense, and where the keypad should go. The guarantee on our installation is ten years on workmanship, and it covers the fitting of the window as a whole. If you are weighing up the choice of unit first, the opening rooflight service page sets out the range, and the skylight installation Basingstoke homepage shows how the rest of our work fits together. When you are ready, book a roof survey and bring your ideas about where the switch should go.

Free roof survey

Tell us about your roof

  • Survey before any quote
  • No obligation
  • Plain-English advice

Say what you have in mind and where. We survey the roof before we quote, then tell you plainly what fits.

Prefer to talk? 01256 213206