GuideEnergy efficient rooflights

Rooflight U-values explained in plain terms

What a rooflight U-value measures, why whole-unit and centre-pane figures differ, and how to compare them fairly on a quote.

Frost on a tiled roof around a roof window
Frost on a tiled roof around a roof window

Every rooflight data sheet carries a figure followed by the letters W/m²K, and it is the one number on the page that tells you how much warmth the unit will let escape on a cold night. It sits among light transmission, g-value, acoustic ratings and dimensions, and it is easy to read it wrongly. Two manufacturers can print what looks like the same figure for two very different pieces of glazing, because they measured different things. This guide takes the U-value apart: what it measures, what goes into it, why a rooflight gets a harder test than a wall window, and how to read it on a quote so that you compare like with like.

None of it needs a physics degree. It needs a handful of plain questions asked in the right order, and those questions are set out below.

What a U-value actually measures

A U-value is a rate. It says how many watts of heat pass through one square metre of a building element for every degree of temperature difference between the inside and the outside. Hence the unit: watts, per square metre, per kelvin (a kelvin step is the same size as a degree Celsius). If the loft room is warm and the night outside is cold, heat is always moving outwards through the glass and frame, and the U-value puts a size on how fast.

The rule that matters most is the direction of travel: a lower U-value means less heat lost. A rooflight with a lower figure holds heat in better than one with a higher figure, all else being equal. It is the reverse of most ratings people meet, where a bigger number is better, and it trips up anyone reading a brochure quickly.

Because the figure is quoted per square metre, it describes the product, not your room. A large unit with a good U-value can still let out more heat in total than a small unit with a poorer one, simply because there is more of it. That is why the size of the opening and the figure on the data sheet have to be read together, a point the guide on balancing daylight gain against heat loss works through when choosing how big to go.

How a sealed rooflight unit works and fails Two close-up edge sections of a double-glazed rooflight unit. On the left a healthy unit: two panes held apart by a warm-edge spacer bar filled with desiccant, primary and secondary seals, a dry sealed cavity and a low-emissivity coating on one inner face. On the right the edge seal has broken, moist air has got in and mist sits between the panes; a small inset shows condensation on the room-side face of the glass instead, which is a ventilation issue, not a failed unit. Healthy unit Failed seal 1234 5678

How a sealed rooflight unit works and fails

  1. Outer and inner glass panes, with the outer pane facing the weather
  2. Low-emissivity coating on one inner face, reflecting heat back into the room
  3. Warm-edge spacer bar holding the panes apart, filled with desiccant to soak up trace moisture
  4. Primary seal against each pane, backed by the secondary seal around the edge
  5. Dry sealed cavity, the insulating layer between the panes
  6. Broken edge seal: moist air gets in and the desiccant becomes saturated
  7. Mist and droplets trapped between the panes; they cannot be wiped off and the sealed unit needs replacing
  8. Inset: condensation on the room-side face of the glass is a ventilation or humidity issue, not a failed unit

Centre-pane or whole unit: the figure that gets swapped

The single most useful thing to know about rooflight U-values is that there are two common versions of the number, and they are not interchangeable.

  • Centre-pane (sometimes written Ug). The glass alone, measured or calculated in the middle of the sealed unit, well away from the edges and the frame. It is always the more flattering figure, because the middle of the glass is the best-performing part of the whole assembly.
  • Whole unit (often written Uw, or for a rooflight sometimes Ur). The glass, the spacer bar at its edge, and the frame or kerb together, averaged over the complete product. This is what the finished rooflight does on your roof.

The rule: compare whole-unit figures with whole-unit figures. A centre-pane number set against a rival's whole-unit number will always make the first product look better than it is. The exception is when you are comparing two glazing options inside the same frame, where the centre-pane figure is a fair way to see what the glass upgrade alone buys you.

If a data sheet only shows one U-value and does not say which, ask. A reputable manufacturer states the basis of the figure, the standard it was calculated to and the angle it applies at, and a quote that repeats the number should repeat the basis too.

What goes into the number

A whole-unit U-value is built up from several parts, and each has its own effect. Seeing them side by side explains why two rooflights that look alike can perform so differently in a cold January.

Loft room with a double glazed roof window set into a sloping insulated ceiling
The glass, its edge and the frame all count towards the whole-unit figure a data sheet prints
The parts of a rooflight that set its U-value
PartWhat it does to heat flowWhat to look for on the sheet
Number of panesEach extra cavity adds another layer of still gas between warm and cold glassDouble or triple, and the width of each cavity
Gas fillArgon or krypton conducts heat less readily than air in the cavityThe gas named, not just "gas filled"
Low-e coatingA thin metal oxide layer reflects radiant heat back into the roomWhich pane face carries it and whether solar control is combined
Spacer barThe strip holding the panes apart; a metal one conducts heat at the edgeWarm edge spacer or aluminium
Frame or kerbTimber, PVC, aluminium or composite; metal needs a thermal breakFrame material and whether it is thermally broken
UpstandOn a flat roof the kerb under the unit is part of the heat pathWhether the quoted figure includes the upstand or excludes it

The glass layers and gas fill are the large levers, and the choice between two and three panes is weighed in the guide to double or triple glazed rooflights. The edge and frame are smaller in area but they are where heat takes the short cut, and they are where condensation tends to show first on a cold morning. The detail of how a frame and its kerb are kept from bridging the cold straight through sits in the guide on thermally broken frames and cold bridging at the upstand.

Why a rooflight has a harder job than a wall window

Put the same sealed unit in a wall and in a roof, and it will not perform the same. Glass tilted towards the sky loses heat faster than glass standing upright, for two reasons that are both standard building physics.

The first is convection inside the cavity. In a vertical unit the gas between the panes circulates slowly in a tall, thin loop. Lay the unit flat or at a shallow pitch and the warm lower pane sits under the cold upper pane, so the gas turns over more readily and carries heat across the gap faster. The second is the view of the sky. A rooflight faces open sky, which on a clear night is very cold, so the outer pane radiates heat away more than a window looking across at a garden fence or a neighbour's wall.

That is why U-values for rooflights come with an angle attached. Many centre-pane glass figures are calculated for glass in the vertical position, as a wall window would be, and the same glass fitted at a low pitch will not match it. A well-made rooflight data sheet says what angle its figure applies to, or states it for the product as installed on a roof. When you see a very low figure on a flat glass rooflight, look for the note that says whether it was worked out upright or horizontal. The honest comparison is between two figures declared at the same angle.

A U-value without its angle and its basis is half a number.

Reading the U-value on a quote, step by step

When a quotation or brochure lands, the same short routine sorts the useful figures from the flattering ones. It takes a few minutes and it means you are comparing products, not marketing.

  1. Find the unit. Check the figure is in W/m²K. Anything else is a different measure, whatever it is called.
  2. Find the basis. Is it centre-pane glass only, or the whole rooflight with frame? Look for Ug against Uw or a note in the small print.
  3. Find the angle. Does the figure apply to the glass upright, horizontal, or at the pitch it will actually be fitted at?
  4. Check what is included. For a flat roof unit, does the number cover the upstand or kerb, or only the glazed part sitting on top of it?
  5. Line up the rivals. Put each product's figure on the same basis and angle before you compare. If one supplier cannot give it, that is worth knowing.
  6. Weigh it against the glass's other jobs. Read the g-value and light transmission alongside the U-value, because the three pull against each other.

The last step matters more on a south-facing slope than on a north one. A rooflight that holds heat in well in winter can let the sun overheat a loft room in July, and the number that governs that is the g-value. The short answer to what the g-value on rooflight glass means explains how the two figures sit side by side on a data sheet.

What the U-value cannot tell you

A U-value is a laboratory figure for a product. Your room gets the product plus the way it was put into the roof, and the number on the sheet says nothing about the second part.

The weak points on a real job are the junctions: where the frame meets the rafters or trusses, where the insulation of the sloping ceiling stops short of the lining, and where the upstand of a flat roof unit meets the deck. Leave a gap in the insulation around a roof window and cold air finds it, and the room feels a cold spot however good the glass is. On a loft conversion the lining and insulation collar around the window are as much part of the thermal result as the sealed unit itself.

That is also why the answer to whether rooflights lose more heat than walls is not settled by the data sheet alone. Glazing of any kind has a higher U-value than a well-insulated wall or roof, so a rooflight will always be a warmer-looking area on a thermal image. The installation decides whether that area is limited to the glass or spreads into the surrounding ceiling.

Sloping loft ceiling with an insulated lining returned neatly around a roof window
Insulation carried tight to the frame keeps the finished room close to what the data sheet promised

Old rooflights on estate houses around Basingstoke

The U-value question comes up sharply on the 1960s to 1980s estates across the borough: Popley, Oakridge, Winklebury, Brighton Hill, Lychpit. Many of these houses were given plastic domes over flat-roofed extensions or early timber roof windows in the slope, and those units were made long before modern low-e coatings, gas fills or warm edge spacers were usual. A single-skin or twin-skin dome on a flat roof, or an early roof window with an air-filled unit and aluminium spacer, sits well behind current glazing on every line of the table above.

Replacing one is the natural moment to set a current U-value in its place, and on a trussed roof it usually means using the existing opening between the trusses, so the thermal gain comes without any change to the structure. The guide on heat loss through old rooflights in 1970s and 1980s homes looks at those original units in more detail, including how to spot which kind you have.

On the newer estates such as Chineham, Hatch Warren and Beggarwood, the rooflights fitted when the houses were built were made to the regulations of their day. If the home may still be under a housebuilder warranty, check its terms before planning any change to the roof.

Where Part L comes in

Approved Document L, the part of the Building Regulations that covers conservation of fuel and power, sets limiting U-values for new and replacement rooflights in existing homes. A rooflight added in a loft conversion or an extension, or one that replaces an old unit, is expected to reach at least that standard. The figure is set on the whole-unit basis, which is one more reason to read quotes on that basis too.

The regulation detail, including how it treats extensions and how it is shown to Building Control, is set out in the guide to Part L and what it asks of a new rooflight. Two short answers pick up the questions owners ask most directly: what U-value a new rooflight should have, and whether a replacement rooflight has to meet Part L. Where the work is notifiable, Everlight submits the Building Control notification as part of the job, and the U-value of the chosen unit is part of what that notification records.

Choosing a figure that suits the room

The lowest U-value on the market is not always the right answer. A small rooflight lighting a landing loses little heat in total whatever glass it has, and the extra cost and weight of the very best glazing buys little there. A large flat rooflight over a kitchen extension, or a bank of roof windows in a loft bedroom that is heated every evening, is a different case: there the whole-unit figure makes a real difference to how the room feels on a winter night.

Weight is a practical limit on a trussed estate roof. Triple glazing is heavier than double, and the frame, flashing and fixings have to be specified for it. Light matters too: every extra pane and coating takes a little from the daylight passing through, so the gain in U-value is traded against a slightly dimmer room. On a north-facing slope that trade is often worth thinking through; on a south-facing one the extra glass can help with summer glare.

The sensible order is roof first, then room, then glass. Know the structure and the opening that fits it, know how the room is used and heated, and then choose the glazing whose whole-unit U-value, g-value and light transmission suit that room. The energy efficient rooflights service page sets out how that specification is worked through on your roof.

A flat-roofed dormer with a rooflight
Figure 2 A flat-roofed dormer with a rooflight

Putting the number to work

A U-value is useful the moment you know which one you are looking at. Ask for the whole-unit figure, ask for the angle it applies at, and ask what it includes at the edges. With those three answers, a quote becomes a like-for-like comparison and the number on the sheet starts to mean the same thing as the warmth in the room.

If you are weighing up new glazing for a loft room, an extension or a tired dome, the rooflight and skylight fitting team in Basingstoke looks at the roof and the room before quoting, and the written quote states the whole-unit U-value of each option so nothing needs translating. Every installation is backed by a 10-year workmanship guarantee (a workmanship promise from us, not insurance backed). To have your roof measured and the glazing options set out against it, arrange a survey, or read more about the energy efficient rooflight service first.

Free roof survey

Tell us about your roof

  • Survey before any quote
  • No obligation
  • Plain-English advice

Say what you have in mind and where. We survey the roof before we quote, then tell you plainly what fits.

Prefer to talk? 01256 213206

Request my survey