GuideEnergy efficient rooflights

Heat loss through old rooflights in 1970s and 1980s homes

Where the warmth escapes from the domes and early roof windows on 1970s and 1980s homes, how to check yours, and what a full replacement changes.

Frost on a tiled roof around a roof window
Frost on a tiled roof around a roof window

Stand under the old dome on a flat-roofed kitchen extension on a January evening and put the back of your hand near it. The air coming off it feels cooler than the rest of the room, and on a still night you may hear the heating click on again sooner than you expected. That is rooflight heat loss you can feel, and on houses built in the 1970s and 1980s it usually comes from glazing and frames that were ordinary when they went in and are now well behind what a new unit can do.

This guide is about those particular rooflights: the plastic domes, the early double glazed roof windows and the timber or aluminium kerbs they sit on. It explains where the warmth escapes, how to tell which parts of yours are to blame, and what changes when the whole unit is replaced rather than the glass alone. The broader picture of glazing choices sits on our energy efficient rooflights page.

Why a rooflight of that age leaks warmth

Warm air rises, so the ceiling is where a room keeps its warmest layer. Any opening in that ceiling is sitting in the hottest air the room has, and the glass above it faces the open sky with nothing to shelter it. A skylight therefore loses heat faster than a wall window of the same size and glazing, simply because of where it is and which way it faces. Our short answer to do rooflights lose more heat than walls? sets out why.

A rooflight from the 1970s or 1980s adds to that with the materials of its time. Glazing was often a single sheet or two sheets of plastic, or a sealed unit filled with dry air rather than a heavier gas. The spacer bar holding the panes apart was metal, which carries cold straight to the edge of the glass. Frames were solid timber or plain aluminium with no break in them, and the kerb or upstand underneath was frequently bare timber with no insulation at all. Each of those is a route out for heat, and on an old unit they all run at once.

Age adds a further layer. Seals on sealed units lose their grip over decades, weatherstrips harden and shrink, and plastic domes turn brittle and cloudy. None of that is a fault of the original fitter; it is what materials do after a long stretch on a roof.

How a sealed rooflight unit works and fails Two close-up edge sections of a double-glazed rooflight unit. On the left a healthy unit: two panes held apart by a warm-edge spacer bar filled with desiccant, primary and secondary seals, a dry sealed cavity and a low-emissivity coating on one inner face. On the right the edge seal has broken, moist air has got in and mist sits between the panes; a small inset shows condensation on the room-side face of the glass instead, which is a ventilation issue, not a failed unit. Healthy unit Failed seal 1234 5678

How a sealed rooflight unit works and fails

  1. Outer and inner glass panes, with the outer pane facing the weather
  2. Low-emissivity coating on one inner face, reflecting heat back into the room
  3. Warm-edge spacer bar holding the panes apart, filled with desiccant to soak up trace moisture
  4. Primary seal against each pane, backed by the secondary seal around the edge
  5. Dry sealed cavity, the insulating layer between the panes
  6. Broken edge seal: moist air gets in and the desiccant becomes saturated
  7. Mist and droplets trapped between the panes; they cannot be wiped off and the sealed unit needs replacing
  8. Inset: condensation on the room-side face of the glass is a ventilation or humidity issue, not a failed unit

The rooflights these houses were given

The estates built around Basingstoke in those two decades, from Oakridge and Popley to Brighton Hill and Lychpit, tended to use a small set of standard products. The table sets out the usual ones, where each loses heat, and what normally takes its place.

Rooflights found on 1970s and 1980s estate homes, and where the heat goes
RooflightHow it was glazedWhere the heat goesUsual replacement
Single skin plastic domeOne moulded acrylic or PVC sheetStraight through the sheet, plus gaps where the dome clamps to the kerbA glazed flat rooflight on an insulated upstand
Twin skin plastic domeTwo plastic sheets with a trapped air gapThrough the thin air gap and the uninsulated kerb beneathA glazed flat rooflight on an insulated upstand
Early timber roof windowAir-filled sealed double glazing with a metal spacerGlass edge, tired weatherstrip, gaps between frame and liningA current roof window in the same opening, with new flashing and insulation collar
Aluminium framed kerb lightSealed unit or wired glass in a plain metal frameThe frame itself, which conducts cold into the roomA thermally broken frame on an insulated upstand

Your own rooflight may be one of these, a later swap, or something the previous owner added. The survey identifies it on the day, but the table is a fair starting guess for a house of that age.

Plastic domes over flat extensions

The plastic dome is the classic rooflight of a 1980s kitchen extension or garage conversion. Its appeal was low cost and simple fitting: a moulded bubble clamped over a timber kerb on the flat roof. Its weakness for heat is that a plastic sheet, even a double one, gives a thin barrier compared with a modern sealed glass unit, and the kerb it sits on was rarely lined with insulation. The ceiling around it may be well insulated, but there is a cold square in the middle.

Plastic also changes with age. It yellows, crazes and loses its clarity, and the fixings that hold the dome to the kerb can work loose so that air finds its way around the rim. Our answer on whether polycarbonate rooflights are energy efficient covers how plastic glazing compares with glass today. For a flat-roofed extension, the like-for-like replacement is usually a glazed flat rooflight on a new insulated upstand, fitted as part of misted and failed rooflight replacement or as a straight upgrade.

Clouded plastic dome rooflight on a flat extension roof beside a pitched tiled house roof
A 1980s plastic dome on a flat kitchen extension, clouded and set on a bare timber kerb

Early roof windows in the pitched slope

On the main roof, the 1970s and 1980s brought the first wave of centre-pivot timber roof windows into loft rooms and over stairwells. They were a real step on from anything before them, and many still open and close. For keeping heat in, though, three things have moved on since they were made.

The first is the sealed unit. It was air-filled, with a metal spacer, so the glass edge runs cold and the centre of the pane gives less resistance than a gas-filled unit with a low-e coating. The second is the weatherstrip around the sash, which by now is often hard and no longer meets the frame all the way round. The third is the gap between the frame and the inside lining, which was often packed loosely or left open when the window went in. Warm air slips into that gap, cools against the roof timbers and can leave damp behind. The detail of how a warm edge spacer changes the glass edge sits in our guide to warm edge spacers and why the glass edge matters.

The kerb, the frame and the gap around them

With old rooflights the glass takes the blame, but the surround often loses as much. A bare timber kerb on a flat roof, a solid aluminium frame, or a lining with a void behind it each form a cold bridge: a strip where heat crosses the roof far more easily than through the insulation next to it. You can often see it as a darker line of mould or a stain along the edge of the reveal.

The rule: a new glazed unit dropped into an old uninsulated kerb or a draughty lining only fixes part of the loss. The exception is a roof window whose frame and lining were insulated properly at the start, where fresh glass and a new weatherstrip may be all it needs; the survey tells you which case you have.

How modern frames and upstands are built to stop that bridging is covered in thermally broken frames and cold bridging at the upstand, and the loft-room side of it in insulating around a roof window in a loft room.

Checking your own rooflight for heat loss

You do not need instruments to get a good idea of where the warmth goes. On a cold, dry evening with the heating on, run through these checks from inside the room.

  1. Feel the air. Hold the back of your hand near the glass, then the frame, then the lining edges. Moving cold air points to a gap; still cold points to the glazing.
  2. Look at the pane. Mist or droplets between the two sheets of glass mean the seal on the unit has gone and the insulating gap no longer works as intended.
  3. Look at the edges. Condensation that forms only at the bottom of the glass, or black spotting on the frame, shows a cold edge or a cold frame.
  4. Check the lining. Staining, flaking paint or mould along the reveal suggests a cold bridge or warm air getting behind the plasterboard.
  5. Try the sash. On an opening roof window, close it and see if it pulls tight all round. Light showing at the edge means the weatherstrip has shrunk.
  6. Note the room. Write down whether the room is the one that is always cooler than the rest of the house. That context helps at the survey.

None of these checks involve going on the roof, and none are a verdict on their own. Together they tell a surveyor which parts of the unit to look at first.

Condensation, the other sign of a cold rooflight

Heat loss and condensation are the same problem seen from two sides. Warm, moist room air meets a surface colder than its dew point and leaves water on it. On an old skylight the coldest surfaces are the glass edge, a metal frame and any uninsulated kerb, which is why drips gather there first and run down the lining. In a kitchen or bathroom, where the air carries more moisture, it is more noticeable still.

A warmer rooflight raises those surface temperatures, so less water forms. Ventilation still matters, and a rooflight cannot make up for a room with no extraction, but the cold surfaces are what the replacement changes. Our answer to do energy efficient rooflights reduce condensation? puts that in a few paragraphs.

On an old rooflight, the drips on the frame are the heat loss made visible.

What changes when the whole unit is replaced

Replacing an old rooflight well means replacing the parts that lose heat, not only the pane. On a flat roof that is normally the dome and the kerb together, with a new insulated upstand and a glazed unit sealed to it. In a pitched roof it is the window, its flashing and the insulation collar and lining around it, fitted to the existing opening where the size still suits the room.

The glazing itself is chosen for the room: double or triple glazed, gas filled, with a low-e coating and warm edge spacers, and with solar control where a south slope would otherwise overheat in summer. Working out what those labels mean in figures belongs to our guide on rooflight U-values explained in plain terms. A replacement is also building work that meets current thermal standards, and does a replacement rooflight have to meet Part L? explains how that applies. Where the work is notifiable, the Building Control notice is ours to deal with.

On a trussed estate roof, the existing opening already sits between two trusses, so a like-for-like width keeps the structure exactly as it is. A bigger opening is a separate conversation about the roof, not about heat.

The survey on a 1970s or 1980s roof

Before any price, we come and look. On a house of this era the survey follows the heat, from the room up to the roof covering.

  1. Inside first. We note the room, the lining, any staining and where the cold is felt, and confirm the rooflight type from the table above.
  2. The loft or ceiling void. Where it can be reached, we check the insulation around the opening and whether the roof is trussed or cut.
  3. The roof. We check the kerb or flashing, the covering, the pitch or the flat roof build-up, and measure the opening.
  4. The specification. We give you a written quote naming the unit, the glazing, the upstand or collar and the lining work, so you can see which heat routes each part closes.
A flat-roofed dormer with a rooflight
Figure 2 A flat-roofed dormer with a rooflight

Before you decide

An old dome or an early roof window can go on letting in daylight for years while quietly costing warmth. Whether it is worth changing now depends on the room, the state of the kerb and lining, and what else is planned for the house, such as a loft conversion or a new flat roof covering on the extension, when it makes sense to do both together.

For the wider options, from glazing to frames, go back to the energy efficient rooflights service. If you are weighing up the whole rooflight or skylight, not just its energy use, the Everlight home page for rooflight installation around Basingstoke is the place to start. Our fitting carries a 10-year workmanship guarantee, which is not insurance backed. When you want your own rooflight looked at in person, arrange a survey of the roof and we will trace where its heat goes.

Free roof survey

Tell us about your roof

  • Survey before any quote
  • No obligation
  • Plain-English advice

Say what you have in mind and where. We survey the roof before we quote, then tell you plainly what fits.

Prefer to talk? 01256 213206