GuideEnergy efficient rooflights

Insulating around a roof window in a loft room

How the gap around a roof window frame is insulated and sealed in a loft room, layer by layer, on trussed estate roofs and older cut rafter roofs.

A warm loft room on a winter day
A warm loft room on a winter day

Stand in a finished loft room on a cold morning and hold the back of your hand near the edge of the roof window, not the glass but the plastered reveal beside it. If that strip feels noticeably cooler than the ceiling a hand's width away, the heat is escaping through the gap around the frame rather than through the pane. Insulating around a roof window is the work that closes that gap, and in a sloping ceiling it matters as much as the glazing you choose.

This guide is about the ring of roof that surrounds the frame: the timbers either side, the insulation that has to meet the frame, the membrane that keeps warm moist air out of the roof, and the lining that finishes it off. It covers loft rooms on the trussed estate houses that make up most of the Basingstoke area and on the older cut rafter roofs in the villages, because the two are insulated in different places.

Why the frame edge is the weak point

A modern rooflight unit is sold with a performance figure for the glass and frame together. That figure assumes the frame sits in a roof that is insulated right up to it. In a real loft room the frame is set into an opening cut through the insulation, and anything left unfilled between the frame and the rafters or trusses becomes a channel for heat. A well chosen unit from our energy efficient rooflight range only delivers its figure once that surround is filled.

The edge is also where the inside surface is coldest. When warm air from the room meets that cold strip, moisture in the air condenses on it, and over time that shows as damp marks or mould in the corners of the reveal. So the job has two aims at once: keep the heat in, and keep the inner face of the reveal warm enough that condensation has nowhere to form. The frame itself plays a part too, which our guide to thermally broken frames and cold bridging explains; this page picks up where the frame meets the roof.

Loft room with a roof window set into a sloping ceiling, the reveal plastered and painted white
The reveal around a roof window is where a loft room gains or loses its warmth
Sizing a roof window to the truss bays On the left, a section through a pitched roof built from Fink trussed rafters, with W-shaped webs joined by nail plates, tiles on battens, and a roof window set in the slope. On the right, the same slope seen square-on: trusses at even 600mm centres with a narrow roof window sitting in the bay between two of them, so no truss is cut. A wider window outline, drawn dashed, crosses a truss and would need designed trimming. Section600mm centresSeen square-on12345678

Sizing a roof window to the truss bays

  1. Fink trussed rafter, factory made and designed to work as one whole frame
  2. W-shaped webs, joined at every node by pressed metal nail plates
  3. Tile covering on battens over the underlay
  4. Roof window set in the slope, fitted between trusses so the frame is untouched
  5. Narrow roof window sitting in the bay between two trusses
  6. Trusses at even 600mm centres along the roof
  7. No truss cut: the trusses either side of the window stay whole
  8. A wider window crosses a truss, so the cut needs designed trimming from an engineer or the truss maker

Where the insulation sits in a loft room

Before anything can be insulated around the window, you need to know where the insulation line runs in the rest of the ceiling. In an ordinary loft used for storage, the insulation lies flat on the ceiling below and the roof space above is cold. Once the loft becomes a room, the insulation has to follow the slope instead, so the room sits inside the warm envelope and the roof covering sits outside it.

On a sloping ceiling that usually means insulation boards fitted between the rafters, often with a further layer fixed across the underside before the plasterboard goes on. Some roofs are insulated on top of the rafters instead, from outside, which is a warm roof build more often seen on a full re-roof than on a room made inside an existing loft. Whichever way the ceiling is done, the roof window has to sit so that its frame lines up with the insulation layer, not above or below it.

The rule: the frame is set at the depth of the insulation, so the insulation layer runs straight into it with no step. The exception is a roof where the insulation is added later on the room side: then the lining around the window has to be built out to meet the frame, and that lining is insulated too.

Getting that depth right is decided at the survey and on fitting day, not afterwards. A frame set too high on the rafters leaves a cold band beneath it that no amount of plaster will warm up.

The layers around a roof window, one by one

From the tiles inwards, the edge of a well insulated roof window is built in a set order. Each layer has one job, and a gap in any one of them lets the others down.

The layers around a roof window in a loft room, outside to inside
LayerWhat it isWhat it does at the window
FlashingThe weathering kit matched to the tiles or slateKeeps rain out of the joint between the frame and the roof covering
Underlay collarA breathable membrane skirt that joins the roof underlay to the frameCarries any water that gets past the tiles around the frame and back onto the underlay
Insulation collarA preformed insulating strip that wraps the outside of the frameFills the gap between the frame and the timbers so heat cannot bypass the frame
Rafter or truss insulationThe boards or quilt already in the sloping ceilingRuns tight up to the collar with no open joint
Vapour control collarA sealed membrane taped from the inner frame to the room side vapour layerStops warm moist room air getting into the cold roof around the frame
LiningThe reveal panels or plasterboard around the openingFinishes the opening, with insulation behind it where the reveal is deep

The roof window makers sell matched insulation and vapour control collars for their own frames, sized to each window. Using the matching collar is the simplest way to make the edge continuous, because it is shaped for that frame and seals to it without improvising.

Trussed estate roofs and the narrow bay

On the post-war and newer estates around the town, from Popley and Winklebury to Chineham and Hatch Warren, the roof is built from factory trusses at 600mm centres. A loft room made inside that kind of roof has usually had its structure redesigned, but where a roof window sits between two trusses or two new rafters, the opening is narrow and the timbers either side are close to the frame.

That closeness helps and hinders. It helps because the gap to fill is small and the insulation collar closes it neatly. It hinders because there is little room to squeeze insulation in by hand, so anything left loose or compressed in that slot does not do its job. The insulation boards in the bays above and below the window also have to be cut to meet the trimmers that form the head and sill of the opening, and those cut edges need to be tight.

If you are still deciding on sizes, a window chosen to fit between the trusses is easier to insulate well than a wide opening with extra trimming, simply because there are fewer junctions. How the width is picked in the first place is covered on our roof window installation service page.

Cut rafter roofs in the older villages

In Old Basing, Overton, Kingsclere and the other older settlements around the town, the loft is more often built from cut rafters on purlins. Rafter depths vary from house to house, and older rafters are often shallower than modern insulation thicknesses would like. That means the room side layer across the rafters does more of the work, and the window lining has to be built out to match it.

These roofs are also more likely to be draughty and to have no modern underlay at all. In that case, how moisture leaves the roof has to be thought about before any insulation goes in around the window, so that the new work does not trap damp against old timber. A conservation rooflight in one of these roofs is insulated on the same principles, just within a slimmer frame and a more careful lining.

A good window set into a badly insulated opening behaves like a poor window.

How the edge is insulated on fitting day

When a new roof window goes into a loft room, or an old one comes out and a new one goes in, the insulation around it is built up in a fixed order so that no layer is covered before it is checked.

  1. Set the frame depth. The frame is fixed with its brackets adjusted so its insulation line matches the depth of the ceiling insulation.
  2. Fit the underlay collar. The breathable skirt is dressed onto the frame and lapped onto the existing underlay, with a drainage gutter above the head.
  3. Wrap the insulation collar. The preformed strip goes round all four sides of the frame and is pressed against the rafters, trusses and trimmers.
  4. Close the flashing and roof covering. The flashing kit goes on and the tiles or slate are laid back to it.
  5. Make good the ceiling insulation. From inside, the cut boards around the opening are trimmed and fitted tight to the collar, and any gap is filled rather than left open.
  6. Seal the vapour control collar. The membrane is taped to the inner frame groove and to the ceiling vapour layer on every side, including the corners.
  7. Line the reveal. The lining panels or insulated plasterboard go in, with the head and sill angled so daylight spreads into the room.

Each of those steps is quick on its own. The quality comes from doing them in that order and not skipping the ones that end up hidden behind the lining.

Condensation, vapour control and ventilation

A loft room makes warm, moist air: people breathing, a shower in an en suite, clothes drying. If that air reaches the cold side of the insulation around the window, it condenses inside the roof where nobody sees it. The vapour control collar is the part that prevents this, and the corners are where it most often fails, because they are awkward to tape.

On the room side, a warmer reveal and a well sealed frame make condensation on the glass and lining less likely, but they do not remove the moisture that is causing it. A loft room still needs a way for that moisture to leave, whether through the window's own ventilation flap, background ventilation elsewhere, or extract in a bathroom. The short answers on whether energy efficient rooflights reduce condensation and whether a new rooflight needs a trickle vent cover those two sides.

Above the insulation, a cold pitched roof also needs its own air path so that any moisture in the roof void can escape. The insulation around the window must not block that path, which is one more reason the collar and the ceiling boards are set to a consistent depth.

Replacing an older window in an existing loft room

Many loft rooms on estate houses have a skylight fitted when the room was first made, often with little or nothing packed around the frame. Swapping the unit for a modern one is the moment to put that right. Once the old frame is out, the opening is clear to see, and the collars and ceiling insulation can be fitted properly around the new frame instead of around a gap that was never filled.

The replacement also has to fit the insulation that is there now, which may be thicker than when the room was built. If the ceiling has been insulated since, the new frame may need to sit at a different depth from the old one, and the lining built out to suit. What older units lose, and why, is set out in our guide to heat loss through old rooflights in 1970s and 1980s homes.

Sloping loft ceiling with a new roof window and freshly finished insulated reveals, bright daylight on the floor
Replacing an older roof window opens up the edge so it can be insulated properly

What Building Regulations look at

Where a roof window is fitted into a room, the thermal side of the job falls under Part L of the Building Regulations. That covers the window's own performance and also the continuity of the insulation at the junction with the roof, because a cold edge undoes a good figure on the glass. Fitting or replacing a roof window is building work, and where it needs a notification, Everlight makes it on your behalf so the completion certificate follows. For what Part L asks in detail, read Part L and what it asks of a new rooflight.

In a loft conversion, the Building Control officer will usually look at the ceiling insulation before it is covered, which is a good moment to check the edges around each window too.

Blinds, linings and the last of the heat

Once the edge is insulated, the remaining heat loss at a roof window is through the glass. A close fitting blind that runs in side channels can hold a layer of still air against the pane on winter nights, which helps a little; our answer on whether rooflight blinds help keep heat in sets out how much to expect from each type.

The lining matters here too. A deep reveal made of insulated board keeps its inner face close to room temperature, so the whole window reads as part of a warm ceiling rather than a cold hole in it. That is also why a loft room with its roof windows properly insulated around the edge does not have to feel colder than the rest of the house, the point made in the answer to do rooflights make a loft conversion colder?

A loft study lit by a top-hung roof window
Figure 2 A loft study lit by a top-hung roof window

Getting the edge right on your own loft room

The glazing figure on a quote is only half of how warm a roof window will feel. The other half is whether the insulation, the vapour layer and the lining meet the frame with no gaps, at the right depth, and in the right order. That is decided by looking at how your particular loft room was built: trusses or cut rafters, insulation between the rafters or across them, and how much depth there is to work with.

When we survey the roof, we look at the ceiling build and the frame depth before we quote, and the written specification says how the edge will be insulated. The work carries a 10-year workmanship guarantee, not insurance backed. You can read how the wider service works on our energy efficient rooflights page, see the whole range of rooflight and skylight work around Basingstoke, or simply arrange a survey of your loft room.

Free roof survey

Tell us about your roof

  • Survey before any quote
  • No obligation
  • Plain-English advice

Say what you have in mind and where. We survey the roof before we quote, then tell you plainly what fits.

Prefer to talk? 01256 213206

Request my survey