Put your hand flat against the frame of an old aluminium rooflight on a cold January morning and then move it to the glass. On many older units the frame feels colder than the pane it holds. That is cold bridging in the most literal sense: a solid path of metal running from the outside air straight into the room, carrying warmth out faster than anything around it. This guide looks at the edges of a rooflight rather than the middle, because the edges are where a well glazed unit can still let a room down.
Two things decide how warm that edge is. One is the frame itself and whether it has a thermal break. The other is the upstand the frame sits on and how the roof insulation meets it. Get both right and the perimeter behaves like the rest of the ceiling. Get either wrong and you have a cold ring around the glass, with the damp corner that tends to follow.
What cold bridging means at a rooflight
Heat leaves a room by the easiest route. Insulation slows it down; solid, dense or metallic materials speed it up. A cold bridge is any spot where a conductive material crosses the insulation layer and links warm inside to cold outside. On a wall that might be a steel lintel or a concrete floor slab running through the cavity. On a roof it is very often the rooflight perimeter, because that is where the insulated roof build-up stops and something else takes over.
The glass in a modern sealed unit is a comparatively good insulator. The frame holding it, the kerb under the frame and the timber trimmers around the opening are all made of other stuff, and each one is a possible short cut. A published U-value for a rooflight describes the unit as tested; it says nothing about how the unit is joined to your roof. For what that figure covers and what it leaves out, see rooflight U-values explained in plain terms.
How a sealed rooflight unit works and fails
- Outer and inner glass panes, with the outer pane facing the weather
- Low-emissivity coating on one inner face, reflecting heat back into the room
- Warm-edge spacer bar holding the panes apart, filled with desiccant to soak up trace moisture
- Primary seal against each pane, backed by the secondary seal around the edge
- Dry sealed cavity, the insulating layer between the panes
- Broken edge seal: moist air gets in and the desiccant becomes saturated
- Mist and droplets trapped between the panes; they cannot be wiped off and the sealed unit needs replacing
- Inset: condensation on the room-side face of the glass is a ventilation or humidity issue, not a failed unit
The three paths heat takes at the edge
It helps to separate the perimeter into three zones, because each one has a different cause and a different answer. A surveyor looking at a flat roof extension or a loft room will think about all three before choosing a product.
| Zone | How the heat gets out | What answers it |
|---|---|---|
| The frame | Metal carries warmth from the inner face to the outer face without interruption | A thermal break: a low conductivity strip that splits the frame into an inner and an outer half |
| The glass edge | A metal spacer bar between the panes conducts along the perimeter of the sealed unit | A warm edge spacer made from a less conductive material |
| The upstand and junction | An uninsulated timber kerb, or a gap where the roof insulation stops short, leaves a band with no thermal cover | An insulated upstand, lined up so the roof insulation runs tight to it with no gap |
The middle row belongs to the sealed unit and is covered in the guide to warm edge spacers and why the glass edge matters. The rest of this page deals with the first and third rows, which are about the frame and the roof it sits in.
What a thermally broken frame actually is
Aluminium is popular for flat roof rooflights and lanterns because it is slim, stiff and durable outdoors. It is also an excellent conductor of heat. A frame extruded as one solid piece of aluminium will pull warmth from the room side to the weather side all day and night through winter.
A thermally broken frame is made in two halves, an outer profile and an inner profile, joined by a strip of low conductivity material, commonly a reinforced polyamide. The strip holds the two halves together structurally but interrupts the metal path. Heat reaching the inner half has to cross that insulating strip to get out, and it does so far more slowly. The inner face of the frame stays closer to room temperature as a result.
A thermal break is not an add-on or an upgrade you can fit later. It is part of how the profile is manufactured, so the question to ask is simply whether the frame on the product in front of you is thermally broken or not. Timber and PVC frames, and the polyurethane frames on many pitched roof windows, do not need one in the same way because the material itself conducts far less; the issue there shifts to how the frame is insulated where it meets the roof.
A good pane in a cold frame on a bare kerb is still a cold rooflight.
Why the upstand matters as much as the frame
A flat roof rooflight sits on an upstand, a raised kerb that lifts the glazing clear of standing water and gives the roof covering something to turn up against. The frame can be as well broken as you like, but it is bolted to whatever that kerb is made of, and the kerb in turn passes right through the roof build-up.
A kerb built on site from plain timber boards is a solid block of wood crossing the insulation line. Timber is far better than metal, but it is still a weaker insulator than the rigid boards in a modern warm roof, so a plain kerb leaves a thin band around the opening where the thermal cover is thinner than everywhere else. Factory upstands designed for energy efficient rooflights are either made of insulating material or have insulation built into them, so the band disappears.
The rule: the insulated upstand should meet the roof insulation with no gap and no step, so the insulation layer is continuous up to the frame. The exception: on an older extension where the roof is insulated at ceiling level rather than on the deck, the upstand still helps but the opening's inner lining needs its own insulation too, because the cold void sits between the deck and the ceiling.
For the short version of whether an efficient unit needs an insulated kerb at all, the answer on whether energy efficient rooflights need an insulated upstand gives it directly. This guide is about why, and what happens at the joint.
Warm deck, cold deck and where the insulation line runs
How the upstand should be detailed depends on how the flat roof is insulated, and around Basingstoke that varies with the age of the extension. Rear kitchen extensions added to estate homes in Popley, Brighton Hill or Oakridge in earlier decades were often built as cold decks: the boards on top, the insulation laid between the joists underneath, and a ventilated gap in between. Newer extensions are more usually warm decks, with rigid insulation laid on top of the deck and the waterproof layer over that.
- Warm deck. The insulation layer is on top of the structure, so the upstand needs to rise through it and be insulated to match. The roof insulation is cut tight around the upstand and the covering is dressed up its face. Done carefully, the thermal layer runs unbroken from the roof to the rooflight frame.
- Cold deck. The insulation is below the deck, so a kerb sitting on the deck is above the insulation line entirely. The opening through the joists needs lining and insulating on its inner faces, and the trimmers around it need covering, or the shaft becomes a cold chimney into the room.
Neither is wrong in itself. What matters is that the rooflight detail follows the roof it is going into. If you are weighing up a new flat roof unit as part of a wider job, the flat roof rooflight installation hub covers the rest of that work.
The same problem on a pitched roof window
A roof window in a sloping ceiling has no upstand, but it has an equivalent weak point: the timber trimmers and the gap between the frame and the surrounding rafters. On an estate roof with trusses at 600mm centres, the window sits between two trusses, and the insulation that fills the rest of the slope has to be brought right up to the frame on all four sides.
Manufacturers of pitched roof windows supply insulation collars for exactly this reason. The collar wraps the outside of the frame and closes the gap the rafter insulation cannot reach. Inside, the lining between the frame and the plasterboard is the other half of the job, and it is covered in detail in the guide to insulating around a roof window in a loft room. The principle is the same as at the upstand: no bare timber and no air gap on the cold side of the insulation line.
Cold edges, condensation and the damp corner
The practical sign of cold bridging is rarely a high heating bill on its own. It is water. Warm, moist air from a kitchen, bathroom or bedroom meets a surface colder than its dew point and condenses. The first surfaces to cross that line are the coldest ones, and at a rooflight those are the frame and the reveal just beside it.
That is why an older skylight can run with droplets along the frame while the middle of the glass stays clear, and why black mould tends to start in the corners of the lining rather than across the whole reveal. A thermally broken frame on an insulated upstand raises the temperature of those surfaces so that condensation forms less readily. It does not replace ventilation: a steamy room still needs its moisture removed. The answer on whether energy efficient rooflights reduce condensation sets out how far glazing alone can go.

Replacing an older unit on an estate extension
Older flat roof extensions and garage conversions on the post-war estates around the town often carry plastic domes or single skin aluminium framed units on plain timber kerbs. When those come to the end of their life, the replacement is a chance to deal with the whole perimeter rather than just the glazing.
- The old kerb. If it is a bare timber upstand, it is usually taken out or built up with insulation to suit the new unit, rather than having the new frame screwed onto the old block.
- The roof around it. The condition and build-up of the surrounding roof tells the surveyor whether it is a warm or cold deck, and so which detail applies.
- The rules. A replacement is still expected to meet current energy standards for the new unit. The answer on whether a replacement rooflight has to meet Part L explains where that applies.
Domed units made from twin or multiwall plastic sheet sit on their own kerbs and behave differently again; how they compare is covered in the answer on whether polycarbonate rooflights are energy efficient.
How the junction is put together
On a flat roof the detail around a thermally broken rooflight follows a steady order. Each step is about keeping the insulation continuous and the weatherproofing sound.
- Confirm the roof build-up. The surveyor checks whether the roof is a warm or cold deck and how deep the insulation is, because the upstand height and detail follow from that.
- Form or trim the opening. The opening is cut to the upstand size, with trimmers where the joists are interrupted, and the edges are left square and sound.
- Set the insulated upstand. The kerb is fixed to the deck, level and square, sized so its top sits clear of the finished roof surface.
- Close the insulation to the kerb. On a warm deck the rigid boards are cut tight to the upstand. On a cold deck the inner faces of the opening are insulated and the trimmers covered.
- Dress the covering. The waterproof layer is taken up the upstand face and finished under the frame, so water has no route in at the joint.
- Fix the frame and finish inside. The rooflight is bedded and fixed to the kerb, and the internal reveal is lined and insulated before it is plastered or boarded.
Where a new or enlarged opening counts as notifiable work, the Building Control notification is part of the job and sits with us rather than with you.
Choosing the right frame for your roof
For a flat roof rooflight or lantern in aluminium, a thermally broken frame is the sensible default for any heated room below. For a pitched roof window, look instead for the manufacturer's insulation collar and a properly insulated lining. In both cases the frame is only as warm as the roof around it, so the upstand or trimmer detail deserves as much attention as the brochure figure for the glass.
If you are sizing the opening as well as choosing the frame, the balance between light and heat loss is weighed in the guide to balancing daylight gain against heat loss. The wider picture of how we specify and fit efficient units is on the energy efficient rooflights page.
Getting the perimeter checked on your own roof
The frame, the kerb and the insulation line can only be judged on the actual roof, which is why we look at it in person and quote afterwards. Our workmanship on the finished junction is covered by a 10-year guarantee, which is not insurance backed. If an old skylight in your extension is cold to the touch at the edges, arrange a survey of the roof and we will show you where the heat is going and which efficient rooflight suits the deck you have. For everything else about new and replacement units around Basingstoke, start from the Everlight homepage.