Energy efficient rooflights in Basingstoke

Rooflights glazed for heat loss and summer sun, insulated into your roof and guaranteed for 10 years.

Will an energy efficient roof window fit between my trusses?

Estate homes around Basingstoke usually have trussed rafter roofs with trusses at 600mm centres. The glazing you choose does not change the width of the window, so the structural question stays the same whether it is double or triple glazed. Here is how the common choices compare, and the survey confirms the spacing on your roof before we quote.

What fits at 600mm truss centres
Narrow window, double or triple glazed: fits between trussesSits in the gap between two trusses whatever glass it carries, with the insulation collar joined to the roof all round.
Two narrow windows: one per bayClose to the glass area of one wide window with the truss left whole, and each frame insulated on all four sides.
One wide window: needs designed trimmingThe opening crosses a truss, so the trimming is designed first, and the larger pane is glazed to hold the extra heat.
Flat roof rooflight on an insulated upstandSized to the flat roof joists, with the upstand insulated so the roof insulation carries on up to the frame.

How it works

Energy efficient rooflights in Basingstoke

Survey before quoteBuilding Control handled10-year workmanship guarantee

Heat leaves a house by the easiest route, and on a winter night the easiest route out of a loft room is usually straight up through the glass. A rooflight lies close to flat, faces the whole of the night sky and sits at the top of the house, where the warmest air collects. That makes it the hardest working piece of glazing in the building, and it is why the glass, the frame and the way it is fitted into the roof all matter more here than in a wall window of the same size. The good news is that a well specified modern rooflight, fitted with its insulation joined up to the roof around it, keeps a room comfortable in January and in July while bringing in daylight that a wall window cannot match.

This page covers energy efficient rooflights and roof windows around Basingstoke from the roof up: why the build era of your house shapes the answer, what the figures on a specification sheet mean, how the glazing options compare, where heat escapes round the frame, how to stop a south-facing loft room overheating, how to size a skylight so the daylight gain outweighs the heat loss, how we fit and insulate it, what Part L and Building Control ask, and what decides the cost. We survey the roof before we quote, and every installation carries our 10-year workmanship guarantee. If you would rather start with someone looking at your own roof, book a roof survey.

Why your roof and its era decide the heat question

Book a roof survey

Basingstoke grew from a market town into one of the big post-war expansion towns, and its roofs tell that story. The estates from the 1960s onward, from Popley and Oakridge to Brighton Hill, Winklebury and later Chineham and Hatch Warren, sit on trussed rafter roofs: factory-made trusses, typically at 600mm centres, each one part of an engineered whole. The villages around the town, such as Old Basing, Overton and Kingsclere, have older cut rafter roofs laid out by hand. Both kinds can take an energy efficient rooflight, but they raise different questions, and the heat question starts with what is already up there.

On a 1970s or 1980s estate house the rooflights already in place are usually of their time. A plastic dome on a flat roofed kitchen or garage conversion, a single glazed or early double glazed timber roof window in a loft room, or a small fixed skylight over a landing was specified to the standards of the day, and those standards asked far less of glazing than the Building Regulations ask now. The seals in early double glazed units age, the gap between the panes loses whatever it held, and the frames were never designed to join up with a modern insulated roof. We look at how much heat those older units give away in heat loss through old rooflights in 1970s and 1980s homes.

Newer homes in places like Beggarwood, Hatch Warren and Chineham were built to later insulation standards, so a rooflight added there has to hold its own against a well insulated roof around it. A weak unit in a warm roof shows up quickly as a cold spot, a draught of falling cool air under the glass, or condensation along the bottom of the frame. On the newest houses, check whether the home is still under a housebuilder warranty and what it says about alterations before any work goes ahead.

Trussed rafter roofs on the Basingstoke estates are usually set out at 600mm centres. A narrow roof window sized for that gap sits between two trusses with no structural change, and the choice of double, triple or vacuum glazing does not change its width. The energy decision and the structural decision can be made separately, which keeps both simple.

Estate house loft room lit by a triple glazed roof window set between two timber trusses
A loft room kept warm in winter by a roof window sized to the gap between the trusses

What makes a rooflight energy efficient: the figures that matter

Book a roof survey

Rooflight specification sheets carry a handful of figures, and each one answers a different question. Read together they tell you how a unit behaves on a cold night, on a hot afternoon and on a grey day when you simply want light. None of them means much alone, and a unit that wins on one can lose on another, so it helps to know what each measures before comparing brochures.

The figures on a rooflight specification sheet
FigureWhat it measuresWhich way is better
U-valueHow readily heat passes through the unit, frame and glass together, from the warm side to the cold sideLower keeps more heat in. Check whether the figure is for the whole unit or the centre of the glass only
g-valueHow much of the sun's heat that lands on the glass passes through into the roomLower keeps a sunny room cooler; higher lets in more free winter warmth. The right figure depends on which way the roof faces
Light transmittanceHow much visible daylight gets through the glassHigher gives a brighter room. Extra panes and heavy solar control coatings bring it down
Air permeabilityHow much air leaks through the closed window at the sealsLower means fewer draughts. It depends on the sash seals and on how squarely the frame is fixed
Frame detailsWhether the frame or upstand has a thermal break and insulation, and what the spacer at the glass edge is made ofA thermally broken frame and a warm edge spacer keep the edges warmer and drier

The U-value is the headline, and it is worth understanding properly. A rooflight's U-value changes with the angle it is assessed at, because warm air moves differently against glass lying flat than against glass standing upright, so the same unit can show a different figure on two sheets. Compare like with like, and ask whether a figure covers the whole unit or only the centre of the pane. Rooflight U-values explained in plain terms walks through the measurement, and what U-value should a new rooflight have? gives the short answer for a new installation.

The g-value is the one people forget. It measures solar heat, not light, and on a roof that faces the sun it can matter as much as the U-value. What is the g-value on rooflight glass? explains it in a few minutes. Figures for glass thickness also appear on sheets, and a thicker unit is not automatically a warmer one: how thick is the glass in an energy efficient rooflight? sorts out what the thickness does and does not tell you.

Double, triple and vacuum glazing compared

Book a roof survey

The glazed unit is where most of the heat question is settled. Every current rooflight uses sealed units of two or more panes, with a coating on at least one pane and a gas or a vacuum in the gap. The choice between them is a balance of heat loss, weight, light and cost, and it is worth deciding with the room in mind rather than simply buying the most panes on offer.

Rooflight glazing options side by side
GlazingHeat lossLight and weightWhere it suits
Double glazed, low-e, argon filledMeets current standards for a new rooflight, a large step up from an old single or early double glazed unitBright and relatively light, so easy on the frame and the roofLandings, bathrooms and rooms used mainly in the day
Triple glazed, low-e, gas filledLower again, and the inner pane stays warmer on a cold nightA little less light and noticeably heavier, which the frame is designed forLoft bedrooms and living rooms used every evening, north-facing slopes
Vacuum glazingVery low for its thickness, because a vacuum carries almost no heat across the gapSlim and light for its performance, with tiny support pillars visible up closeConservation style frames with slim profiles, and slim replacement units
Laminated inner paneLittle direct change to heat loss; it is chosen for safety overheadHolds together if broken, and reduces noiseAny rooflight over a space where people stand or sleep

Triple glazing earns its keep where a room is used on winter evenings and where the rooflight is large compared with the room. A dark north-facing slope over a loft bedroom is the classic case. On a south-facing roof the gain is smaller, because the sun already warms the glass on winter days, and the extra pane trims the daylight a little. Double or triple glazed rooflights sets out the trade-off in full, and is triple glazing worth it in a rooflight? gives the direct answer.

What sits between the panes

The gap between the panes is filled with a heavy inert gas, usually argon, which carries heat across the gap more slowly than air. Krypton does the same job in a narrower gap, which is why it appears in slimmer triple glazed and conservation units. The gas slowly escapes over the life of a unit, which is one reason an old sealed unit performs worse than its original figures. Argon and krypton filled rooflight glazing explains the difference and why it matters for slim frames. Vacuum glazing removes the gas altogether and holds the panes apart with small pillars; vacuum glazing in rooflights looks at where it makes sense and what to expect from it.

The edge of the unit is the weak point of any sealed pane. The spacer bar that holds the panes apart used to be aluminium, which conducts heat well and leaves a cold strip round the edge of the glass where condensation forms first. A warm edge spacer made from a less conductive material keeps that strip warmer. Warm edge spacers and why the glass edge matters covers it, and does laminated glass make a rooflight warmer? answers a question that comes up whenever safety glass is specified.

Frames, upstands and cold bridging

Book a roof survey

A rooflight with excellent glass can still lose heat through its edges. The frame, the upstand it sits on and the join between them and the roof insulation form the perimeter of the opening, and any piece of material that runs from the warm inside to the cold outside without a break acts as a bridge for heat. The result is a cold line inside, where warm moist air meets a cool surface and condensation forms. On a pitched roof window the frame is designed with this in mind, and the installation collar closes the gap between it and the insulation. On a flat roof the upstand, sometimes called the kerb, carries the rooflight above the roof surface, and how it is built decides a lot.

The rule: the insulation in the roof and the insulation round the rooflight must meet, with no gap and no solid path of timber or metal running from inside to outside.

The exception: some structure has to pass through, such as the timber that frames the opening. There the detail is designed so the insulation wraps it, a thermally broken frame or an insulated upstand carries the line on, and the vapour control layer is taped to the frame.

Aluminium and steel frames conduct heat readily, so a good metal framed rooflight has a thermal break: a strip of low conductivity material separating the inner and outer parts of the frame. Timber and composite frames conduct less, but they still need insulating where they meet the roof. Thermally broken frames and cold bridging at the upstand goes through each frame type and the details at the corners, where cold bridges are easiest to miss.

On a flat roofed extension the upstand is as important as the glass. A bare timber kerb with no insulation leaves a cold ring round the opening, whatever the rooflight above it is like. An insulated upstand, either built on site or supplied with the rooflight, carries the roof insulation up to the frame. Do energy efficient rooflights need an insulated upstand? explains why, and our flat roof rooflight installation page covers the flat roof job as a whole, from falls to finishes.

Cold bridges and condensation go together. A modern unit with warm edges and an insulated frame keeps its inner surfaces warmer, so there is less condensation to wipe away in the morning, though ventilation still matters in any room with people and steam in it. Do energy efficient rooflights reduce condensation? sets out what the glazing can do and what depends on how the room is used.

Keeping a loft room cool in summer

Book a roof survey

A rooflight is the part of the house that meets the summer sun most directly. On a south or west-facing slope, the sun lands on the glass for much of a long afternoon at a steep angle, and a loft room under a warm roof has little to buffer that heat. Heat loss in winter and heat gain in summer are two sides of the same specification, and a rooflight chosen for one without the other can leave a bedroom too warm to sleep in on a July night.

Glass answers much of it. A solar control coating reflects a large part of the sun's heat while letting most of the visible light through, which lowers the g-value without making the room gloomy. A low-e coating works on the other kind of heat, the long wave warmth given off by a warm room, and reflects it back inside in winter. Many current units carry both on different faces of the glass. Solar control and low-e coatings on rooflight glass explains which coating sits where and why. People sometimes worry that solar control glass will darken a room; does solar control glass make a room darker? answers that plainly.

The glass is not the only tool. An external awning blind stops the sun before it reaches the pane, which is the most effective way to keep a roof window from heating a room. An opening sash, set to vent at the top of the room where warm air gathers, lets the heat out on summer evenings. An electric roof window with a rain sensor can be left venting while you are out. Overheating in south-facing loft rooms and how glazing answers it brings these together, and can a rooflight keep a room cool in summer? gives the short version. An opening or powered sash is chosen at the same time as the glass, so it is worth deciding early.

Blinds help in winter too. An internal blackout or thermal blind closed at night adds a layer of trapped air against the glass and cuts the cold down draught from a large pane. Do rooflight blinds help keep heat in? explains which types help and how much to expect from them.

South facing loft bedroom with roof windows and pale awning blinds on a bright summer afternoon
A loft bedroom kept comfortable under summer sun by solar control glass and external blinds

Sizing a skylight for daylight against heat loss

Book a roof survey

Every square metre of rooflight lets in daylight and lets out heat. Glass, even the best glass, loses heat faster than an insulated roof, so the aim is not the biggest opening but the one that gives the room the light it needs. Light from above is strong: a rooflight faces the whole sky rather than a slice of it, so it brings more daylight into a room than a wall window of the same size. That means a modest skylight can do the work a much larger wall window would, and the heat cost of the right size is small compared with the benefit of daylight all day.

The size that suits a room depends on its depth, the colour of its walls and ceiling, what it is used for and which way the roof faces. A north-facing slope gives soft, even light and little summer heat, so it can take a larger area of glass with triple glazing to hold the warmth in. A south-facing slope gives stronger light and plenty of summer heat, so a smaller or solar control unit can light the same room. Balancing daylight gain against heat loss when sizing rooflights works through the thinking, and which way should a rooflight face for energy? covers orientation on its own.

On a trussed estate roof, sizing also has a structural side. A narrow roof window sits in the gap between two trusses at 600mm centres with no change to the structure. Two narrow windows in neighbouring bays give close to the glass area of one wide window, with the truss left whole between them, and each window is insulated on all four sides. A wider window crosses a truss and needs designed trimming, and it also puts more glass in one place. Our roof window installation page sets out the widths that fit between trusses and when a wider opening is designed.

The rule: size the rooflight for the light the room needs, then choose the glazing to hold the heat.

The exception: in a loft conversion the Building Regulations look at the room as a whole, so a large area of glazing may need to be balanced by better glass or better insulation elsewhere in the room. We check that against the design at the survey.

Daylight has an energy value of its own. A room lit well from above in the day needs no lights on until dusk, which matters most in spaces with no wall window at all: an internal landing, a bathroom in the middle of the house, a long kitchen extension. Can a rooflight cut lighting use during the day? looks at that side of the balance, and does a rooflight let in more light than a wall window? explains why light from above goes further.

How we survey, fit and insulate an energy efficient rooflight

Book a roof survey

A rooflight performs as well as its installation lets it. The glazing figures come from the factory; the insulation, the seals and the join with the roof come from the fitting. Here is the order of the job for a roof window in a pitched, tiled roof, with the points where the energy detail is settled.

  1. Survey. We look at the roof from outside and from the loft, measure the truss or rafter spacing, check the pitch, the tile type and which way the slope faces, and look at the insulation already in the roof. We talk through how the room is used, then specify the size, the glazing and any blinds before we quote.
  2. Protect and open up. Floors and furniture inside are covered and the room below is sealed off. Tiles round the window position are lifted and stacked for reuse, and the battens and underlay are cut back to the opening.
  3. Frame the opening. Between trusses, trimmers go across the top and bottom of the opening without touching the trusses. Where a wider window needs a designed opening, the trimming is fitted exactly as the design sets out.
  4. Fix the frame. The frame goes on its brackets at the depth the flashing needs, checked for square so the sash seals evenly all round. A frame out of square leaks air at the seals however good the glass is.
  5. Insulate the perimeter. An insulation collar is fitted round the frame, joining it to the insulation in the roof, and the underlay collar is dressed into its gutter at the head of the frame.
  6. Flash and relay. The flashing kit for your tiles or slate goes on piece by piece, and the tiles are relaid round it.
  7. Seal the warm side. A vapour control layer is taped to the frame inside and joined to the one in the ceiling, so warm moist air stays out of the cold roof.
  8. Line and hand over. The reveals are insulated and boarded, the window is tested, and we show you how to vent it and how to use any blinds. We complete the Building Control notification and clear away everything we brought.

In a loft room the insulation round the window is often where a good rooflight is let down. The reveals between the frame and the plasterboard are a short run of wall that faces straight into the cold roof space, and they need insulating as carefully as the slope around them. Insulating around a roof window in a loft room goes through the layers, and do rooflights make a loft conversion colder? answers the worry directly.

Flashing, linings and a warm finished reveal

Book a roof survey

Outside, the flashing keeps the weather out of the roof round the frame. Each roof covering has its own kit: a flashing with a flexible apron for the concrete interlocking tiles found across the Basingstoke estates, soakers interleaved with the courses for plain clay tiles in the villages, and a low profile flashing for slate. A recessed installation sets the frame lower in the roof for a flatter look, which suits conservation areas. The flashing also sets how deep the frame sits, which affects where the insulation collar lands, so it is chosen at the survey rather than on the day.

Inside, the lining joins the frame to the ceiling. Its shape does two jobs. It spreads the daylight into the room, and it decides where warm air sits against the glass. A lining with a level top reveal and a vertical bottom reveal lets warm room air rise freely across the pane, which keeps the inner glass warmer and drier.

The rule: the top reveal is formed level and the bottom reveal vertical, so light spreads and warm air washes the glass.

The exception: where a truss web, a purlin or a low ceiling gets in the way, the reveal follows what the structure allows, and we keep the insulation behind it continuous whatever its shape.

For a landing or hallway under a loft, the lining becomes a light shaft through the cold roof space. Every side of that shaft is a wall between warm and cold, so it is insulated along its full length as it is built. Left bare, a shaft cools the air inside it and sends a steady cold draught down onto the landing. A sun tunnel is another way to bring daylight down through a loft with a small opening; it can suit where a roof window and shaft would be awkward to form.

Part L, ventilation and Building Control

Book a roof survey

A new rooflight is building work under the Building Regulations. Part L, the part that deals with conservation of fuel and power, sets a limiting U-value that a new rooflight must meet, and the figure is assessed for the rooflight in its installed position so that flat and pitched units are compared fairly. Part A covers the structure round the opening, and in a loft bedroom the fire safety rules can call for an escape window. Part L and what it asks of a new rooflight explains the energy side in detail.

Replacing an existing rooflight is also covered. A replacement is a controlled fitting under Part L, so the new unit has to meet the current standard rather than the one the old unit was made to, and the work has to be notified. Installers who belong to a competent person scheme self-certify, while other work goes through a Building Control notification to the council or an approved inspector. We handle the Building Control notification where the work is notifiable, and you receive the completion paperwork for your records, which matters when you come to sell. Does a replacement rooflight have to meet Part L? gives the short answer.

The rule: a replacement rooflight must meet the current energy standard and must not leave the room with less ventilation than it had before.

The exception: where the room has other background ventilation that meets Part F, or the window's own ventilation flap does the job, a separate trickle vent may not be needed. The detail depends on the room and the unit.

Part F deals with ventilation, and it matters more as rooms get tighter. A well sealed rooflight removes a draught the old one may have provided, so the question of background ventilation needs an answer. Many roof windows carry a ventilation flap in the frame that lets air through with the sash closed. Does a new rooflight need a trickle vent? explains how the rule works for roof windows.

Energy Performance Certificates are a separate matter again. An EPC records the glazing and insulation of a home as part of a standard assessment, and a rooflight is one element among many. Does a rooflight change a home's EPC rating? explains how the assessment treats it, without promising a result. Planning permission is its own question too: a rooflight on the rear slope of an ordinary house is usually permitted development, while conservation areas, front slopes, flats and listed buildings need checking, and any application is assessed on merit.

Replacing old rooflights for better efficiency

Book a roof survey

Replacing an old rooflight is often the single biggest energy improvement you can make to a loft room or a flat roofed extension, because the glazing it replaces was made to standards that asked so much less. The job is framed by what is there now. The table below sets out the common older types on estate and village roofs around Basingstoke and what a replacement changes.

Older rooflight types and what replacing them changes
Existing unitWhere you find itWhat a replacement changes
Single or twin skin plastic domeFlat roofed kitchens, garage conversions and porches on 1960s to 1980s estatesA sealed glass unit on an insulated upstand, with far lower heat loss and a clear view of the sky
Early timber roof windowLoft rooms converted in the 1970s and 1980sA current unit with low-e glass, gas fill, warm edges and an insulation collar joined to the roof
Misted double glazed unitAny older roof window whose seal has failedThe gas has gone and moisture has got in, so a new unit or window restores the lost performance
Small fixed skylightLandings and bathrooms on older houses and cottagesA properly insulated frame and shaft, often with an opening sash for ventilation

Plastic domes deserve a word of their own. Multiwall polycarbonate and twin skin domes are light and tough, but a plastic skin does not match a sealed glass unit with coatings and gas for keeping heat in, and older domes lose clarity as they age. Are polycarbonate rooflights energy efficient? compares them fairly. Where a roof window has misted between the panes, the seal has gone and the unit no longer performs as it did; our misted and failed rooflight replacement page explains when the glass alone can be changed and when the whole window is replaced.

Glass that stays clean lets in more light, and some units offer an outer coating that breaks down dirt in sunlight and lets rain rinse it away. It makes no difference to heat loss, but it helps a hard to reach rooflight keep its daylight. What is self-cleaning rooflight glass? explains how it works. And if you are weighing up whether the heat lost through a rooflight is worth worrying about at all, do rooflights lose more heat than walls? puts the comparison in plain terms.

What decides the cost, and the survey

Book a roof survey

Two energy efficient rooflights of the same size can be very different jobs, so the price comes from the survey, not from a list. What we can set out here is what moves the cost, so the written quote holds no surprises.

  • The glazing. Double, triple or vacuum glazing, solar control coatings and self-cleaning glass each change the unit.
  • Size and structure. A window between the trusses is the simplest job; a designed opening adds the design, the timber and the time.
  • The roof. Pitched or flat, the covering and its flashing, and on a flat roof whether the upstand is built new and insulated.
  • Access. Whether scaffold is needed and how easy the slope is to reach.
  • The inside. A short insulated lining in a loft room, or an insulated light shaft through a loft to a landing, plus any plastering and decorating.
  • Blinds and controls. Awning blinds, thermal or blackout blinds, rain sensors and any electrical connection for a powered window.
  • Number of rooflights. Several on one slope share the access and set-up.

At the survey we look at the roof, the loft and the room, check which way the slope faces and what insulation is already there, and talk through how you use the space. We tell you which widths fit between your trusses, which glazing suits the room and the orientation, and whether anything needs designing or checking first. The written quote follows from what we found on your roof. For a wider view of our rooflight installation work across the Basingstoke area, the homepage is the place to start.

Every installation carries our 10-year workmanship guarantee. It covers the fitting work we carry out, it comes from us directly, and it is not insurance backed. The rooflight itself comes with its maker's product guarantee, and we give you the details of both at handover. If a colder loft room or a hot bedroom is what brought you here, book a roof survey, or call 01256 213206, and we will tell you what fits your roof and why.

How a job runs

  1. Roof survey

    We inspect your roof and recommend what will fit and perform.

  2. Installation

    Our team installs with care, keeping your home protected.

  3. Sign-off and guarantee

    We complete the sign-off and issue your 10-year workmanship guarantee.

Energy efficient rooflight guides

Frequently asked questions

Is triple glazing worth it in a rooflight?

It is worth it where a room is used on winter evenings, the rooflight is large for the room, or the slope faces north. On a sunny south-facing slope the gain is smaller and the extra pane trims the light a little, so a good double glazed unit with solar control can suit better. Is triple glazing worth it in a rooflight? weighs it up.

What U-value should a new rooflight have?

A new rooflight must meet the limiting U-value set in Part L of the Building Regulations, assessed for the unit in its installed position, and current double and triple glazed units are made to meet it. Lower is better for heat loss. What U-value should a new rooflight have? explains how to read the figures.

Does a replacement rooflight have to meet Part L?

Yes. A replacement rooflight is a controlled fitting, so the new unit has to meet the current energy standard rather than the one the old unit was made to, and the work has to be notified. We handle the Building Control notification. Does a replacement rooflight have to meet Part L? has the detail.

Can a rooflight keep a room cool in summer?

It can help a great deal. Solar control glass lowers the heat the sun brings through, an external awning blind stops the sun before it reaches the glass, and an opening sash lets warm air out at the top of the room. Can a rooflight keep a room cool in summer? explains each.

Do rooflights make a loft conversion colder?

A well specified rooflight fitted with an insulation collar, a sealed vapour control layer and insulated reveals keeps a loft room comfortable. Cold loft rooms usually come from gaps in the insulation round the frame or from old glazing. Do rooflights make a loft conversion colder? covers what makes the difference.

Free roof survey

Tell us about your roof

  • Survey before any quote
  • No obligation
  • Plain-English advice

Say what you have in mind and where. We survey the roof before we quote, then tell you plainly what fits.

Prefer to talk? 01256 213206

Request my survey